Resolution-enhanced reflection ptychography with axial distance calibration

被引:3
|
作者
Chen, Chuangchuang [1 ]
Liu, Jiamin [1 ]
Zhu, Jinlong [1 ,2 ]
Gu, Honggang [1 ,2 ]
Liu, Shiyuan [1 ,2 ]
机构
[1] Huazhong Univ Sci & Technol, State Key Lab Digital Mfg Equipment & Technol, Wuhan 430074, Hubei, Peoples R China
[2] Opt Valley Lab, Hubei 430074, Peoples R China
关键词
Reflection ptychography; Axial distance calibration; Resolution enhanced; Computational imaging; POSITION CORRECTION; WIDE-FIELD; DIFFRACTION; COHERENT; RECONSTRUCTION; ALGORITHM; OBJECT;
D O I
10.1016/j.optlaseng.2023.107684
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Reflection ptychography is a lens-free computational imaging technology that operates by a coherent beam illuminated to a specimen inclined to the optical axis, a set of distorted diffracted patterns is captured on the far-filed plane. This tilted distortion results from the tilt angle of illumination in a reflection mode as a non-coplanar scattering geometry, which mismatches the Fourier transformed distribution and blocks the operation of FFT (fast Fourier Transform) in standard ptychographic reconstruction algorithms. This distortion can be corrected by performing a coordinate transform from the tilted geometry combined with knowledge of the axial distance of diffraction and the radiation wavelength. However, practically the axial distance usually cannot be measured with accuracy instead of a rough estimate, which may disrupt the correction from distortion, and degrade the reconstructed quality significantly. Here, we propose and analyze for the first time a straightforward axial distance calibration approach to improve the reconstructed resolution in reflection ptychography. Firstly, a uniform Fraunhofer-shaped diffraction is transformed from the tilted distorted scatterings by a coordinate transform at a coarse estimate of axial distance. Then, the axial distance error can be precisely corrected from the periodic unwrapped phase of the retrieved probe by ptychography. Finally, a resolution-enhanced reconstruction is generated from the reflection ptychography with axial distance calibration. A group of proof-of-concept experiments was performed for verification. Results demonstrate that the axial distance can be precisely calibrated within a fraction of a millimeter. Moreover, the reconstructed resolution is remarkably improved (2 times improvement in our experimental tests) by utilizing the proposed approach in reflection ptychography.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] A Resolution-Enhanced Digital Micromirror Device (DMD) Projection System
    Zhang, Yijing
    Surman, Phil
    He, Sailing
    IEEE ACCESS, 2021, 9 : 78153 - 78164
  • [32] Resolution-enhanced x-ray ghost imaging with polycapillary optics
    Li, Huiquan
    Hou, Wanting
    Ye, Zhiyuan
    Yuan, Tianyu
    Shao, Shangkun
    Xiong, Jun
    Sun, Tianxi
    Sun, Xuepeng
    APPLIED PHYSICS LETTERS, 2023, 123 (14)
  • [33] Resolution-enhanced integral imaging microscopy that uses lens array shifting
    Lim, Young-Tae
    Park, Jae-Hyeung
    Kwon, Ki-Chul
    Kim, Nam
    OPTICS EXPRESS, 2009, 17 (21): : 19253 - 19263
  • [34] Resolution-Enhanced Base-Type-Edited HCN Experiment for RNA
    Hélène Van Melckebeke
    Arthur Pardi
    Jérôme Boisbouvier
    Jean-Pierre Simorre
    Bernhard Brutscher
    Journal of Biomolecular NMR, 2005, 32 : 263 - 271
  • [35] RESOLUTION-ENHANCED FOURIER-TRANSFORM INFRARED-SPECTROSCOPY OF ENZYMES
    SUSI, H
    BYLER, DM
    METHODS IN ENZYMOLOGY, 1986, 130 : 290 - 311
  • [36] 3D resolution-enhanced intensity diffraction tomographic microscopy
    Li, Jiaji
    Matlock, Alex
    Li, Yunzhe
    Chen, Qian
    Tian, Lei
    Zuo, Chao
    OPTICS FRONTIER ONLINE 2020: OPTICS IMAGING AND DISPLAY, 2020, 11571
  • [37] Resolution-enhanced optical coherence tomography based on classical intensity interferometry
    Lajunen, Hanna
    Torres-Company, Victor
    Lancis, Jesus
    Friberg, Ari T.
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2009, 26 (04) : 1049 - 1054
  • [38] Resolution-enhanced base-type-edited HCN experiment for RNA
    Van Melckebeke, H
    Pardi, A
    Boisbouvier, J
    Simorre, JP
    Brutscher, B
    JOURNAL OF BIOMOLECULAR NMR, 2005, 32 (04) : 263 - 271
  • [39] Resolution-enhanced digital in-line holography by extension of the computational bandwidth
    Zhang, Wenhui
    Zhang, Hao
    Jin, Guofan
    OPTICS COMMUNICATIONS, 2020, 472
  • [40] Evaluation of the Spatial Pattern of the Resolution-Enhanced Thermal Data for Urban Area
    Feng, Xiao
    Li, Jiyuan
    JOURNAL OF SENSORS, 2020, 2020