Resolution-enhanced reflection ptychography with axial distance calibration

被引:3
|
作者
Chen, Chuangchuang [1 ]
Liu, Jiamin [1 ]
Zhu, Jinlong [1 ,2 ]
Gu, Honggang [1 ,2 ]
Liu, Shiyuan [1 ,2 ]
机构
[1] Huazhong Univ Sci & Technol, State Key Lab Digital Mfg Equipment & Technol, Wuhan 430074, Hubei, Peoples R China
[2] Opt Valley Lab, Hubei 430074, Peoples R China
关键词
Reflection ptychography; Axial distance calibration; Resolution enhanced; Computational imaging; POSITION CORRECTION; WIDE-FIELD; DIFFRACTION; COHERENT; RECONSTRUCTION; ALGORITHM; OBJECT;
D O I
10.1016/j.optlaseng.2023.107684
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Reflection ptychography is a lens-free computational imaging technology that operates by a coherent beam illuminated to a specimen inclined to the optical axis, a set of distorted diffracted patterns is captured on the far-filed plane. This tilted distortion results from the tilt angle of illumination in a reflection mode as a non-coplanar scattering geometry, which mismatches the Fourier transformed distribution and blocks the operation of FFT (fast Fourier Transform) in standard ptychographic reconstruction algorithms. This distortion can be corrected by performing a coordinate transform from the tilted geometry combined with knowledge of the axial distance of diffraction and the radiation wavelength. However, practically the axial distance usually cannot be measured with accuracy instead of a rough estimate, which may disrupt the correction from distortion, and degrade the reconstructed quality significantly. Here, we propose and analyze for the first time a straightforward axial distance calibration approach to improve the reconstructed resolution in reflection ptychography. Firstly, a uniform Fraunhofer-shaped diffraction is transformed from the tilted distorted scatterings by a coordinate transform at a coarse estimate of axial distance. Then, the axial distance error can be precisely corrected from the periodic unwrapped phase of the retrieved probe by ptychography. Finally, a resolution-enhanced reconstruction is generated from the reflection ptychography with axial distance calibration. A group of proof-of-concept experiments was performed for verification. Results demonstrate that the axial distance can be precisely calibrated within a fraction of a millimeter. Moreover, the reconstructed resolution is remarkably improved (2 times improvement in our experimental tests) by utilizing the proposed approach in reflection ptychography.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Resolution-enhanced ptychography framework with an equivalent upsampling and precise position
    Lv, Wenjin
    Zhang, Junhao
    Chen, Hao
    Yang, Dongyu
    Ruan, Tianhao
    Zhu, Yupeng
    Tao, Ye
    Shi, Yishi
    APPLIED OPTICS, 2022, 61 (10) : 2903 - 2909
  • [2] Resolution-Enhanced Parallel Coded Ptychography for High-Throughput Optical Imaging
    Jiang, Shaowei
    Guo, Chengfei
    Song, Pengming
    Zhou, Niyun
    Bian, Zichao
    Zhu, Jiakai
    Wang, Ruihai
    Dong, Pei
    Zhang, Zibang
    Liao, Jun
    Yao, Jianhua
    Feng, Bin
    Murphy, Michael
    Zheng, Guoan
    ACS PHOTONICS, 2021, 8 (11): : 3261 - 3271
  • [3] aPIE: an angle calibration algorithm for reflection ptychography
    de Beurs, Anne
    Loetgering, Lars
    Herczog, Milan
    Du, Mengqi
    Eikema, Kjeld S. E.
    Witte, Stefan
    OPTICS LETTERS, 2022, 47 (08) : 1949 - 1952
  • [4] Resolution-enhanced phase retrieval for fringe reflection technology with structured light illumination
    Shen, Xianmeng
    Ren, Maoyun
    Ma, Suodong
    Xu, Shengzhi
    Liu, Mingrui
    Zheng, LiChen
    OPTICAL METROLOGY AND INSPECTION FOR INDUSTRIAL APPLICATIONS VIII, 2021, 11899
  • [5] Resolution-enhanced photometric stereo
    Tan, Ping
    Lin, Stephen
    Quan, Long
    COMPUTER VISION - ECCV 2006, PT 3, PROCEEDINGS, 2006, 3953 : 58 - 71
  • [6] Resolution-enhanced entanglement detection
    Gessner, Manuel
    Pezze, Luca
    Smerzi, Augusto
    PHYSICAL REVIEW A, 2017, 95 (03)
  • [7] Reflective Fourier ptychography-based depth-recovery & resolution-enhanced real scene hologram acquisition method
    Qian, Xin
    Ai, Lingyu
    Shi, Xiao
    Dong, Yue
    Cho, Myungjin
    JOURNAL OF OPTICS, 2023, 25 (06)
  • [8] Resolution-Enhanced Polarimetric Terahertz Imaging
    Hossain, Maruf Md. Sajjad
    Nahar, Niru K.
    Sertel, Kubilay
    IEEE TRANSACTIONS ON TERAHERTZ SCIENCE AND TECHNOLOGY, 2024, 14 (05) : 675 - 690
  • [9] Resolution-enhanced spectroscopy of Y-81
    Schnare, H
    Winter, G
    Kaubler, L
    Reif, J
    Schwengner, R
    Doring, J
    Johns, GD
    Tabor, SL
    Gross, CJ
    Akovali, YA
    Baktash, C
    Stracener, DW
    Durham, FE
    Hua, PF
    Korolija, M
    LaFosse, DR
    Sarantites, DG
    Lee, IY
    Macchiavelli, AO
    Rathbun, W
    VanderMolen, A
    PHYSICAL REVIEW C, 1997, 56 (02): : 729 - 744
  • [10] Resolution-enhanced imaging with quantum correlations
    Toninelli, E.
    Moreau, P. -A.
    Mihalyi, A.
    Gregory, T.
    Edgar, M. P.
    Padgett, M. J.
    2018 CONFERENCE ON LASERS AND ELECTRO-OPTICS (CLEO), 2018,