Background: Non-invasive glycogen quantification in vivo could provide crucial information on biological processes for glycogen storage disorder. Using dual-energy computed tomography (DECT), this study aimed to assess the viability of quantifying glycogen content in vitro.Methods: A fast kilovolt-peak switching DECT was used to scan a phantom containing 33 cylinders with different proportions of glycogen and iodine mixture at varying doses. The virtual glycogen concentration (VGC) was then measured using material composition images. Additionally, the correlations between VGC and nominal glycogen concentration (NGC) were evaluated using least-square linear regression, then the calibration curve was constructed. Quantitative estimation was performed by calculating the linearity, conversion factor (inverse of curve slope), stability, sensitivity (limit of detection/limit of quantification), repeatability (inter-class correlation coefficient), and variability (coefficient of variation).Results: In all conditions, excellent linear relationship between VGC and NGC were observed (P<0.001, coefficient of determination: 0.989-0.997; residual root-mean-square error of glycogen: 1.862-3.267 mg/mL). The estimated conversion factor from VGC to NGC was 3.068-3.222. In addition, no significant differences in curve slope were observed among different dose levels and iodine densities. The limit of detection and limit of quantification had respective ranges of 6.421-15.315 and 10.95-16.46 mg/mL. The data demonstrated excellent scan-repeat scan agreement (inter-class correlation coefficient, 0.977-0.991) and small variation (coefficient of variation, 0.1-0.2%).Conclusions: The pilot phantom analysis demonstrated the feasibility and efficacy of detecting and quantifying glycogen using DECT and provided good quantitative performance with significant stability and reproducibility/variability. Thus, in the future, DECT could be used as a convenient method for glycogen quantification to provide more reliable information for clinical decision-making.
引用
收藏
页码:4933 / 4942
页数:10
相关论文
共 50 条
  • [21] Dual-energy CT for liver iron quantification in patients with haematological disorders
    Sebastian Werner
    Bernhard Krauss
    Ulrike Haberland
    Malte Bongers
    Uwe Starke
    Tamam Bakchoul
    Sigrid Enkel
    Konstantin Nikolaou
    Marius Horger
    European Radiology, 2019, 29 : 2868 - 2877
  • [22] Quantification of iodine concentration by dual-energy CT in patients with acute pancreatitis
    Utrera Perez, E.
    Tardaguila de la Fuente, G.
    Martinez Rodriguez, C.
    Villanueva Campos, A.
    Jurado Basildo, C.
    Garcia Pouton, N.
    RADIOLOGIA, 2020, 62 (05): : 360 - 364
  • [23] Dual-energy CT of the abdomen
    Morgan, Desiree E.
    ABDOMINAL IMAGING, 2014, 39 (01): : 108 - 134
  • [24] Dual-energy CT of the abdomen
    Desiree E. Morgan
    Abdominal Imaging, 2014, 39 : 108 - 134
  • [25] Nonuniqueness in dual-energy CT
    Levine, Zachary H.
    MEDICAL PHYSICS, 2017, 44 (09) : E202 - E206
  • [26] Differentiation with the Dual-Energy CT
    Krome, Susanne
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2011, 183 (08): : 689 - 689
  • [27] Dual-Energy CT of the Pancreas
    Mastrodicasa, Domenico
    Delli Pizzi, Andrea
    Patel, Bhavik Natvar
    SEMINARS IN ULTRASOUND CT AND MRI, 2019, 40 (06) : 509 - 514
  • [28] Dual-Energy CT of the Lung
    Lu, Guang Ming
    Zhao, Yan'E
    Zhang, Long Jiang
    Schoepf, U. Joseph
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 199 (05) : S40 - S53
  • [29] Dual-Energy CT of the Heart
    Vliegenthart, Rozemarijn
    Pelgrim, Gert Jan
    Ebersberger, Ullrich
    Rowe, Garrett W.
    Oudkerk, Matthijs
    Schoepf, U. Joseph
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 199 (05) : S54 - S63
  • [30] Potential role of dual-energy CT imaging modality in the neoadjuvant radiotherapy: a phantom study
    Gallo, P.
    D'Alesssio, A.
    Padelli, F.
    Fumagalli, M. L.
    D'ippolito, E.
    Giandini, T.
    Tenconi, C.
    Cavatorta, C.
    Bruzzone, M. G.
    Pignoli, E.
    De Martin, E.
    RADIOTHERAPY AND ONCOLOGY, 2019, 133 : S1130 - S1130