Comparative study of three different fixation techniques for the treatment of Neer type IIb distal clavicle fractures: A retrospective cohort study

被引:0
|
作者
Liu, Zhi-Qing [1 ]
Zhang, Ming-Shi [1 ]
Zhou, Zi-Fei [1 ]
Zhang, Lei [1 ]
Zheng, Long-Po [1 ]
机构
[1] Tongji Univ, Shanghai Peoples Hosp 10, Sch Med, Dept Orthoped, Shanghai, Peoples R China
来源
FRONTIERS IN SURGERY | 2023年 / 10卷
基金
中国国家自然科学基金; 国家重点研发计划;
关键词
Neer type IIb distal clavicle fractures; locking plate; suture button; outcome; complications; PLATE;
D O I
10.3389/fsurg.2023.1100720
中图分类号
R61 [外科手术学];
学科分类号
摘要
BackgroundRecently, a locking plate (LP) combined with a suture button was applied for distal clavicle Neer type IIb fractures. However, to our knowledge, there is limited information on clinical outcomes surrounding locking plates combined with a suture button in the treatment of Neer type IIb distal clavicle fractures. The aim of this study was to compare the outcomes among three different fixation techniques for the treatment of Neer type IIb distal clavicle fractures. MethodsWe performed a retrospective cohort study of 53 patients with Neer type IIb distal clavicle fractures who were treated with a hook plate (HP group, 16 patients), a locking plate alone (LP group, 18 patients), or a locking plate with a suture button (LPSB group, 19 patients) in our hospital between March 2014 and August 2019. The clinical and radiological outcomes were evaluated, including union time, postoperative complications, and function of the shoulder joint. ResultsThe follow-up period was at least 2 years for all patients. All patients in the LPSB group achieved bone healing at the final follow-up. No significant differences were observed, including age, sex, side, time to surgery, duration of surgery, and mean follow-up period among the three groups (p > 0.05). The union time was shorter in the LPSB group than in the other two groups (p < 0.05). Postoperative complications were lower in the LPSB group than in the other two groups (p < 0.05). The visual analog scale score and Constant-Murley score in the LPSB group were better than those in the other groups at 3 and 6 months postoperatively (p < 0.05). ConclusionCompared with HP and LP alone, LPSB yields better clinical outcomes and lower complication rates in the treatment of Neer type IIb distal clavicle fractures.
引用
收藏
页数:6
相关论文
共 50 条
  • [41] Biomechanical Analysis of Superior and Anterior Precontoured Plate Fixation Techniques for Neer Type II-A Clavicle Fractures
    Worhacz, Kellen
    Nayak, Aniruddh N.
    Boudreaux, Robert L.
    Pavan, Beatrice
    Wipf, Felix
    Jacofsky, Marc C.
    Araghi, Arash
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2018, 32 (12) : E462 - E468
  • [42] Comparison of Locking Plate Fixation and Coracoclavicular Ligament Reconstruction for Neer Type 2B Distal Clavicle Fractures
    Kim, Dong Jin
    Lee, Yoon Min
    Yoon, Eun Ji
    Sur, Yoo Joon
    ORTHOPAEDIC JOURNAL OF SPORTS MEDICINE, 2022, 10 (03)
  • [43] Precontoured Locking Compression Plate with Titanium Alloy Cable System: In Treatment of Neer Type IIb Distal Clavicle Fracture
    Xie, Zheng
    Song, Mengxiong
    Zhou, Jun
    Yin, Gang
    Lin, Haodong
    ORTHOPAEDIC SURGERY, 2021, 13 (02) : 451 - 457
  • [44] Displaced Neer Type IIB distal-third clavicle fractures—Long-term clinical outcome after plate fixation and additional screw augmentation for coracoclavicular instability
    Thomas M. Tiefenboeck
    Sandra Boesmueller
    Harald Binder
    Adam Bukaty
    Michael M. Tiefenboeck
    Julian Joestl
    Marcus Hofbauer
    Roman C. Ostermann
    BMC Musculoskeletal Disorders, 18
  • [45] Displaced Neer Type IIB distal-third clavicle fractures-Long-term clinical outcome after plate fixation and additional screw augmentation for coracoclavicular instability
    Tiefenboeck, Thomas M.
    Boesmueller, Sandra
    Binder, Harald
    Bukaty, Adam
    Tiefenboeck, Michael M.
    Joestl, Julian
    Hofbauer, Marcus
    Ostermann, Roman C.
    BMC MUSCULOSKELETAL DISORDERS, 2017, 18 : 1 - 6
  • [46] Biomechanical study of two different fixation methods for the treatment of Neer III proximal humerus fractures
    Cheng, Bangjun
    Jiang, Xiping
    Zhang, Xiaofeng
    Guo, Shixin
    Chen, Qi
    Du, Shengchao
    Luo, Yi
    He, Yaohua
    BMC MUSCULOSKELETAL DISORDERS, 2024, 25 (01)
  • [47] Treatment of distal clavicle fractures using a Scorpion plate and influence of timing on surgical outcomes: a retrospective cohort study of 105 cases
    Furuhata, Ryogo
    Takahashi, Masaaki
    Hayashi, Teppei
    Inagawa, Miyu
    Kono, Aki
    Matsumura, Noboru
    Kamata, Yusaku
    Arino, Hiroshi
    Morioka, Hideo
    BMC MUSCULOSKELETAL DISORDERS, 2020, 21 (01)
  • [48] Treatment of distal clavicle fractures using a Scorpion plate and influence of timing on surgical outcomes: a retrospective cohort study of 105 cases
    Ryogo Furuhata
    Masaaki Takahashi
    Teppei Hayashi
    Miyu Inagawa
    Aki Kono
    Noboru Matsumura
    Yusaku Kamata
    Hiroshi Arino
    Hideo Morioka
    BMC Musculoskeletal Disorders, 21
  • [49] Do multiple fractures affect risk of fixation failure after surgical treatment of midshaft clavicle fracture? A retrospective cohort study
    Hyojune Kim
    Taeho Oh
    Sang Ki Lee
    Archives of Orthopaedic and Trauma Surgery, 2024, 144 (1) : 121 - 130
  • [50] Do multiple fractures affect risk of fixation failure after surgical treatment of midshaft clavicle fracture? A retrospective cohort study
    Kim, Hyojune
    Oh, Taeho
    Lee, Sang Ki
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2024, 144 (01) : 121 - 130