Impact of 3-second rule for high confidence assignment on the performance of endoscopists for the real-time optical diagnosis of colorectal polyps

被引:0
|
作者
Kim, Jung [1 ,2 ]
Lim, Seon Hee [1 ,2 ]
Kang, Hae Yeon [1 ,2 ]
Song, Ji Hyun [1 ,2 ]
Yang, Sun Young [1 ,2 ]
Chung, Goh Eun [1 ,2 ]
Jin, Eun Hyo [1 ,2 ]
Choi, Ji Min [1 ,2 ]
Bae, Jung Ho [1 ,2 ,3 ,4 ]
机构
[1] Seoul Natl Univ Hosp, Healthcare Syst Gangnam Ctr, Dept Internal Med, Seoul, South Korea
[2] Seoul Natl Univ Hosp, Healthcare Res Inst, Seoul, South Korea
[3] Seoul Natl Univ Hosp, Dept Internal Med, Healthcare Syst Gangnam Ctr, Gangnam Finance Ctr 39FL, 152 Teheran Ro, Seoul 06236, South Korea
[4] Seoul Natl Univ Hosp, Healthcare Syst Gangnam Ctr, Gangnam Finance Ctr 39FL, Healthcare Res Inst, 152 Teheran Ro, Seoul 06236, South Korea
关键词
D O I
10.1055/a-2073-3411
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background Confusion between high and low confidence decisions in optical diagnosis hinders the implementation of real-time optical diagnosis in clinical practice. We evaluated the effect of a 3-second rule (decision time limited to 3 seconds for a high confidence assignment) in expert and nonexpert endoscopists.Methods This single-center prospective study included eight board-certified gastroenterologists. A 2-month baseline phase used standard real-time optical diagnosis for colorectal polyps <10 mm and was followed by a 6-month intervention phase using optical diagnosis with the 3 -second rule. Performance, including high confidence accuracy, and Preservation and Incorporation of Valuable Endoscopic Innovations (PIVI) and Simple Optical Diagnosis Accuracy (SODA) thresholds, was measured.Results Real-time optical diagnosis was performed on 1793 patients with 3694 polyps. There was significant improve-ment in high confidence accuracy between baseline and in-tervention phases in the nonexpert group (79.2 % vs. 86.3%; P = 0.01) but not in the expert group (85.3% vs. 87.5%; P=0.53). Using the 3-second rule improved the overall per-formance of PIVI and SODA in both groups.Conclusions The 3-second rule was effective in improving real-time optical diagnosis performance, especially in non -experts.
引用
收藏
页码:945 / 951
页数:7
相关论文
共 50 条
  • [31] Impact of high speed network on performance of real-time concurrency control protocol
    Lee, VCS
    Lam, KY
    Hung, SL
    JOURNAL OF SYSTEMS ARCHITECTURE, 1996, 42 (6-7) : 531 - 546
  • [32] Artificial Intelligence (AI) in Endoscopy-Deep Learning for Optical Biopsy of Colorectal Polyps in Real-Time on Unaltered Endoscopic Videos
    Byrne, Michael F.
    Chapados, Nicolas
    Soudan, Florian
    Oertel, Clemens
    Perez, Milagros L. Linares
    Kelly, Raymond
    Iqbal, Nadeem
    Chandelier, Florent
    Rex, Douglas K.
    GASTROINTESTINAL ENDOSCOPY, 2017, 85 (05) : AB364 - AB365
  • [33] Automated Diagnosis System for Colorectal Polyps Using Endocytoscopy: an Initial Report of a "High-Performance" Second-Generation Model
    Mori, Yuichi
    Kudo, Shin-Ei
    Wakamura, Kunihiko
    Misawa, Masashi
    Ogawa, Yushi
    Ishibashi, Fumiaki
    Kutsukawa, Makoto
    Kudo, Toyoki
    Hayashi, Takemasa
    Miyachi, Hideyuki
    Katagiri, Atsushi
    Baba, Toshiyuki
    Ishida, Fumio
    Inoue, Haruhiro
    GASTROINTESTINAL ENDOSCOPY, 2015, 81 (05) : AB159 - AB160
  • [34] Diagnostic accuracy of i-scan image enhancement for real-time endoscopic diagnosis of small colorectal polyps: a meta-analysis
    Glover, Ben
    Patel, Nisha
    Ashrafian, Hutan
    Teare, Julian
    THERAPEUTIC ADVANCES IN GASTROENTEROLOGY, 2018, 11
  • [35] Prospective real-time evaluation of diagnostic performance using endocytoscopy in differentiating neoplasia from nonneoplasia for colorectal diminutive polyps(≤ 5 mm)
    Takahiro Utsumi
    Yasushi Sano
    Mineo Iwatate
    Hironori Sunakawa
    Akira Teramoto
    Daizen Hirata
    Santa Hattori
    Wataru Sano
    Noriaki Hasuike
    Kazuhito Ichikawa
    Takahiro Fujimori
    World Journal of Gastrointestinal Oncology, 2018, (04) : 96 - 102
  • [36] FEATURE-BASED REAL-TIME COMPUTER-AIDED DIAGNOSIS OF COLORECTAL POLYPS USING MULTI-LABEL CONVOLUTIONAL NEURAL NETWORKS
    Rodriguez-Diaz, Eladio
    Ravikumar, Varun A.
    Singh, Satish K.
    GASTROINTESTINAL ENDOSCOPY, 2022, 95 (06) : AB261 - AB261
  • [37] ASGE Technology Committee reviews on real-time endoscopic assessment of the histology of diminutive colorectal polyps, and high-definition and high-magnification endoscopes
    Basford, Peter
    Longcroft-Wheaton, Gaius
    Bhandari, P.
    GASTROINTESTINAL ENDOSCOPY, 2015, 82 (06) : 1139 - 1140
  • [38] The impact of real-time 3d imaging by ultra-high speed optical coherence tomography in urothelial carcinoma
    Ikeda, Masaomi
    Matsumoto, Kazumasa
    Choi, Donghak
    Nishi, Morihiro
    Fujita, Tetsuo
    Ohbayashi, Kohji
    Shimizu, Kimiya
    Iwamura, Masatsugu
    BMC UROLOGY, 2013, 13
  • [39] The impact of real-time 3d imaging by ultra-high speed optical coherence tomography in urothelial carcinoma
    Masaomi Ikeda
    Kazumasa Matsumoto
    Donghak Choi
    Morihiro Nishi
    Tetsuo Fujita
    Kohji Ohbayashi
    Kimiya Shimizu
    Masatsugu Iwamura
    BMC Urology, 13
  • [40] ASGE Technology Committee reviews on real-time endoscopic assessment of the histology of diminutive colorectal polyps, and high-definition and high-magnification endoscopes Response
    Abu Dayyeh, Barham
    Banerjee, Subhas