Design of cold-formed high strength steel rectangular hollow section T-joints under post-fire conditions

被引:7
|
作者
Pandey, Madhup [1 ]
Young, Ben [2 ]
机构
[1] Univ Nottingham, Dept Civil Engn, Nottingham, England
[2] Hong Kong Polytech Univ, Dept Civil & Environm Engn, Hong Kong, Peoples R China
关键词
Cold-formed steel; Design rules; FE analysis; High strength steel; Post-fire; Tubular joints; BEHAVIOR;
D O I
10.1016/j.jcsr.2023.107941
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
A comprehensive numerical investigation looking into the static post-fire structural performance of cold-formed high strength steel (CFHSS) T-joints is presented in this paper. The braces and chords of T-joints were made of square and rectangular hollow section (SHS and RHS) members. The steel grade of SHS and RHS members was S960 with nominal 0.2% proof stress of 960 MPa. The static strengths of SHS and RHS T-joints were investigated corresponding to four post-fire temperatures, including 300 degrees C, 550 degrees C, 750 degrees C and 900 degrees C. Pandey and Young [1] carried out tests to investigate the post-fire residual strengths of cold-formed S960 steel grade SHS and RHS Tjoints. The test results were used to develop an accurate finite element (FE) model. Using the validated FE model, a comprehensive FE parametric study was performed in this investigation. The validity ranges of critical geometric parameters were extended beyond the current limits mentioned in international codes and guides. The nominal resistances predicted from design equations given in EC3 [2] and CIDECT [3], using post-fire material properties, were compared with a total of 765 test and FE joint resistances, including 756 numerical data obtained in this study. Overall, SHS and RHS T-joint specimens were failed by chord face failure, chord side wall failure and a combination of these two failure modes. Generally, the current design rules in EC3 [2] and CIDECT [3] are quite conservative and largely dispersed. As a result, accurate, less dispersed and reliable design equations are proposed in this study.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] Design of Cold-Formed High-Strength Steel Diamond Bird-Beak Tubular T-Joints and X-Joints
    Pandey, Madhup
    Young, Ben
    JOURNAL OF STRUCTURAL ENGINEERING, 2023, 149 (08)
  • [22] Ultimate resistances of member-rotated cold-formed high strength steel tubular T-joints under compression loads
    Pandey, Madhup
    Young, Ben
    ENGINEERING STRUCTURES, 2021, 244
  • [23] Post-Fire Behavior of Cold-Formed Steel Semi-Oval Hollow Stub Columns
    Zuo, Wenkang
    Chen, Man-Tai
    Young, Ben
    JOURNAL OF STRUCTURAL ENGINEERING, 2024, 150 (10)
  • [24] Post-fire local buckling behaviour of cold-formed S700 high strength steel circular hollow sections under axial compression: Experiments, modelling and design
    Zhong, Yukai
    Su, Andi
    Zhao, Ou
    THIN-WALLED STRUCTURES, 2023, 184
  • [25] Cold-formed steel T-joints with semi-oval hollow section chord: Experimental insight and finite element modelling
    Oeng, Pouykang
    Chen, Man-Tai
    Young, Ben
    ce/papers, 2023, 6 (3-4) : 1562 - 1567
  • [26] Experimental investigation of cold-formed stainless steel tubular T-joints
    Feng, Ran
    Young, Ben
    THIN-WALLED STRUCTURES, 2008, 46 (10) : 1129 - 1142
  • [27] The capacity of cold-formed rectangular hollow section K-gap joints
    Björk, T
    Marquis, G
    Kemppainen, R
    Ilvonen, R
    TUBULAR STRUCTURES X, 2003, : 227 - 234
  • [28] Behaviour and design of cold-formed ultra-high-strength steel hollow section column members
    Saumiyaa, K. S.
    Anbarasu, M.
    Sonkar, Chanchal
    STRUCTURES, 2024, 68
  • [29] Design of cold-formed steel oval hollow section columns
    Zhu, Ji-Hua
    Young, Ben
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2012, 71 : 26 - 37
  • [30] Numerical investigation on post-fire resistance of cold-formed Q960 ultra high strength steel channel section stub columns
    Xue, Xuanyi
    Chan, Tak-Ming
    Young, Ben
    STRUCTURES, 2024, 66