Real-Time Continuous Glucose Monitoring in the Hospital: A Real-World Experience

被引:9
|
作者
Bagsic, Samantha R. Spierling R. [1 ]
Fortmann, Addie L. L. [1 ]
Belasco, Rebekah [1 ]
Bastian, Alessandra [1 ]
Lohnes, Suzanne [1 ]
Ritko, Anna [2 ]
Sandoval, Haley [1 ]
Chichmarenko, Mariya [1 ]
Soriano, Emily C. C. [1 ]
Talavera, Laura [1 ]
Philis-Tsimikas, Athena [1 ]
机构
[1] Scripps Hlth, Scripps Whittier Diabet Inst, 10140 Campus Point Dr,Suite 200, San Diego, CA 92121 USA
[2] Scripps Hlth, San Diego, CA USA
来源
关键词
CGM; continuous glucose monitoring; glycemic control; hospital; diabetes; GLYCEMIC CONTROL; HYPOGLYCEMIA; HYPERGLYCEMIA; ARRHYTHMIAS; MANAGEMENT;
D O I
10.1177/19322968231165982
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Glycemic control in the hospital setting is imperative for improving outcomes among patients with diabetes. Bedside point-of-care (POC) glucose monitoring has remained the gold standard for decades, while only providing momentary glimpses into a patient's glycemic control. Continuous glucose monitoring (CGM) has been shown to improve glycemic control in the ambulatory setting. However, a paucity of inpatient experience and data remains a barrier to US Food and Drug Administration (FDA) approval and expanded/non-research use in the hospital setting. Method: Amid the COVID-19 pandemic, the FDA exercised its enforcement discretion to not object to the use of CGM systems for the treatment of patients in hospital settings to support COVID-19 health care-related efforts to reduce viral exposure of health care workers. Following this announcement, Scripps Health, a large not-for-profit health care system in San Diego, California, implemented CGM as the new "standard of care" (CGM as SOC) for glucose monitoring and management in the hospital. Results: The present report serves to (1) detail the implementation procedures for employing this new SOC; (2) describe the patients receiving CGM as SOC, their glycemic control, and hospital outcomes; and (3) share lessons learned over two years and nearly 900 hospital encounters involving CGM. Conclusions: Here, we conclude that CGM is feasible in the hospital setting by using a dedicated diabetes care team and the CGM technology with remote monitoring.
引用
收藏
页码:656 / 666
页数:11
相关论文
共 50 条
  • [21] New perspectives on real-time continuous glucose monitoring Comment
    Stechova, Katerina
    LANCET CHILD & ADOLESCENT HEALTH, 2021, 5 (04): : 235 - 236
  • [22] Accuracy of a new real-time continuous glucose monitoring algorithm
    Navas de Solis, M. S.
    AVANCES EN DIABETOLOGIA, 2010, 26 (02): : 129 - 130
  • [23] Real-time continuous glucose monitoring: proven clinical indiciations
    Gomez Peralta, Fernando
    Abreu Padin, Cristina
    AVANCES EN DIABETOLOGIA, 2011, 27 (06): : 198 - 203
  • [24] DIABETES Under Control Real-Time Continuous Glucose Monitoring
    Ramchandani, Neesha
    Saadon, Yael
    Jornsay, Donna
    AMERICAN JOURNAL OF NURSING, 2010, 110 (04) : 60 - 63
  • [25] Design and implementation of real-time continuous glucose monitoring instrument
    实时动态血糖监测器的设计与实现
    Liu, Hongying (liu_hongying@163.com), 2017, West China Hospital, Sichuan Institute of Biomedical Engineering (34):
  • [26] Is reimbursement for alerts and real-time continuous glucose monitoring needed?
    Norgaard, Kirsten
    Schmidt, Signe
    LANCET, 2021, 397 (10291): : 2230 - 2232
  • [27] Real-World Outcomes of Continuous Glucose Monitoring in Adults with Diabetes Mellitus attending an Irish Tertiary Hospital
    Courtney, Aoife
    Smith, Diarmuid
    Forde, Hannah
    IRISH JOURNAL OF MEDICAL SCIENCE, 2024, 193 : S142 - S142
  • [28] Real-world outcomes of continuous glucose monitoring in adults with diabetes mellitus attending an Irish tertiary hospital
    Aoife Courtney
    Diarmuid Smith
    Hannah Forde
    Irish Journal of Medical Science (1971 -), 2023, 192 : 2763 - 2768
  • [29] Real-world outcomes of continuous glucose monitoring in adults with diabetes mellitus attending an Irish tertiary hospital
    Courtney, Aoife
    Smith, Diarmuid
    Forde, Hannah
    IRISH JOURNAL OF MEDICAL SCIENCE, 2023, 192 (06) : 2763 - 2768
  • [30] REAL-TIME CONTINUOUS GLUCOSE MONITORING VERSUS SELF MONITORING OF BLOOD GLUCOSE IN TYPE 1 DIABETES: REAL-WORLD DATA FROM A LARGE US MULTI-CENTER STUDY
    Noor, N.
    Norman, G.
    Jones, N. -H. Yayah
    Majidi, S.
    Indyk, J.
    Clements, M.
    Dei-Tutu, S.
    Ebekozien, O.
    Desalvo, D.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2021, 23 : A32 - A33