Compensation for respiratory motion-induced signal loss and phase corruption in free-breathing self-navigated cine DENSE using deep learning

被引:7
|
作者
Abdi, Mohamad [1 ,2 ,4 ]
Bilchick, Kenneth C. [2 ]
Epstein, Frederick H. [1 ,3 ]
机构
[1] Univ Virginia, Dept Biomed Engn, Charlottesville, VA USA
[2] Univ Virginia Hlth Syst, Dept Cardiovasc Med, Charlottesville, VA USA
[3] Univ Virginia Hlth Syst, Dept Radiol, Charlottesville, VA USA
[4] Univ Virginia, Dept Biomed Engn & Cardiovasc Med, Charlottesville, VA 22908 USA
基金
美国国家卫生研究院;
关键词
deep learning; DENSE MRI; free-breathing MRI; myocardial strain; respiratory motion compensation; STIMULATED ECHOES; TRACKING;
D O I
10.1002/mrm.29582
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeTo introduce a model that describes the effects of rigid translation due to respiratory motion in displacement encoding with stimulated echoes (DENSE) and to use the model to develop a deep convolutional neural network to aid in first-order respiratory motion compensation for self-navigated free-breathing cine DENSE of the heart.MethodsThe motion model includes conventional position shifts of magnetization and further describes the phase shift of the stimulated echo due to breathing. These image-domain effects correspond to linear and constant phase errors, respectively, in k-space. The model was validated using phantom experiments and Bloch-equation simulations and was used along with the simulation of respiratory motion to generate synthetic images with phase-shift artifacts to train a U-Net, DENSE-RESP-NET, to perform motion correction. DENSE-RESP-NET-corrected self-navigated free-breathing DENSE was evaluated in human subjects through comparisons with signal averaging, uncorrected self-navigated free-breathing DENSE, and breath-hold DENSE.ResultsPhantom experiments and Bloch-equation simulations showed that breathing-induced constant phase errors in segmented DENSE leads to signal loss in magnitude images and phase corruption in phase images of the stimulated echo, and that these artifacts can be corrected using the known respiratory motion and the model. For self-navigated free-breathing DENSE where the respiratory motion is not known, DENSE-RESP-NET corrected the signal loss and phase-corruption artifacts and provided reliable strain measurements for systolic and diastolic parameters.ConclusionDENSE-RESP-NET is an effective method to correct for breathing-associated constant phase errors. DENSE-RESP-NET used in concert with self-navigation methods provides reliable free-breathing DENSE myocardial strain measurement.
引用
收藏
页码:1975 / 1989
页数:15
相关论文
共 4 条
  • [1] Noncontrast free-breathing respiratory self-navigated coronary artery cardiovascular magnetic resonance angiography at 3 T using lipid insensitive binomial off-resonant excitation (LIBRE)
    Jessica A. M. Bastiaansen
    Ruud B. van Heeswijk
    Matthias Stuber
    Davide Piccini
    Journal of Cardiovascular Magnetic Resonance, 21
  • [2] Noncontrast free-breathing respiratory self-navigated coronary artery cardiovascular magnetic resonance angiography at 3T using lipid insensitive binomial off-resonant excitation (LIBRE)
    Bastiaansen, Jessica A. M.
    van Heeswijk, Ruud B.
    Stuber, Matthias
    Piccini, Davide
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2019, 21 (1)
  • [3] Phase2Phase Respiratory Motion-Resolved Reconstruction of Free-Breathing Magnetic Resonance Imaging Using Deep Learning Without a Ground Truth for Improved Liver Imaging
    Eldeniz, Cihat
    Gan, Weijie
    Chen, Sihao
    Fraum, Tyler J.
    Ludwig, Daniel R.
    Yan, Yan
    Liu, Jiaming
    Vahle, Thomas
    Krishnamurthy, Uday
    Kamilov, Ulugbek S.
    An, Hongyu
    INVESTIGATIVE RADIOLOGY, 2021, 56 (12) : 809 - 819
  • [4] Free-breathing cine imaging with motion-corrected reconstruction at 3T using SPiral Acquisition with Respiratory correction and Cardiac Self-gating (SPARCS)
    Zhou, Ruixi
    Yang, Yang
    Mathew, Roshin C.
    Mugler, John P., III
    Weller, Daniel S.
    Kramer, Christopher M.
    Ahmed, Abdul Haseeb
    Jacob, Mathews
    Salerno, Michael
    MAGNETIC RESONANCE IN MEDICINE, 2019, 82 (02) : 706 - 720