Three-Dimensional Analysis of Porosity in As-Manufactured Glass Fiber/Vinyl Ester Filament Winded Composites Using X-Ray Micro-Computed Tomography

被引:5
|
作者
Srivastava, Chaman [1 ]
Agostino, Pietro [2 ]
Stamopoulos, Antonios G. [2 ]
Alcock, Ben [3 ]
Strandlie, Are [1 ]
Grammatikos, Sotirios [1 ]
机构
[1] Norwegian Univ Sci & Technol, Dept Mfg & Civil Engn, ASEMlab Lab Adv & Sustainable Engn Mat Res, Grp Sustainable Composites, N-2815 Gjovik, Norway
[2] Univ Aquila, Dept Ind & Informat Engn & Econ DIIIE, Via Giovanni Gronchi 18, I-67100 Laquila, Italy
[3] SINTEF Ind, Dept Mat & Nanotechnol, N-0373 Oslo, Norway
关键词
Filament winding; CT Analysis; Polymer-matrix composite; CARBON-FIBER COMPOSITES; WINDING PARAMETERS; RESOLUTION; CT; SIMULATION; COMPACTION; BEHAVIOR; QUALITY; DAMAGE; VOIDS;
D O I
10.1007/s10443-023-10167-z
中图分类号
TB33 [复合材料];
学科分类号
摘要
Filament winding is a technique to manufacture tubular composite structures and, therefore, is among the most appealing techniques for fabricating critical structures such as hollow tubes. Despite the recent advances, these structures are prone to a varying degree of porosity that may affect their mechanical performance. Therefore, the accurate detection and quantification of the manufacturing porosity is crucial. Micro-CT is most suitable for performing this activity at various scales. This work employs micro-CT for studying porosity inside an as-manufactured filament-winded composite structure. Void characteristics like volume, orientation, size, and relative volume fraction inside the hoop and helical layers are quantified inside a representative curved panel extracted from a glass fiber-vinyl ester tubular composite structure, which has not been studied in detail previously. It was observed that most voids are present in the matrix region. The voids are elliptical rod-like and spherical, with the latter present in the helical layers, which also host the majority of voids and the highest void volume fractions. The voids are highly aligned along the fiber orientation direction with higher misorientations for helical layers than the hoop layer. Large voids in base layers were created due to gaps formed during the winding process. Hence, the main goal of this study is to measure the voids' characteristics and the volumetric fraction during the stacking of filament wound hoop and helical layers during a generic filament winding pattern. The data can be further exploited as input for modeling filament winded composites in the presence of voids by researchers.
引用
收藏
页码:171 / 200
页数:30
相关论文
共 50 条
  • [41] Effects of structural defects on low-velocity impact damage mechanisms of three-dimensional braided composites based on X-ray micro-computed tomography
    Sun, Mengyao
    Liu, Xiaodong
    Zhang, Diantang
    Sun, Jin
    Qian, Kun
    POLYMER TESTING, 2021, 104 (104)
  • [42] Application of X-ray micro-computed tomography on macroporous calcium phosphate glass scaffolds
    Kim, MC
    Lee, BH
    Kim, KN
    Kim, KM
    Choi, SH
    Kim, CK
    LeGeros, RZ
    Lee, YK
    BIOCERAMICS 18, PTS 1 AND 2, 2006, 309-311 : 1087 - 1090
  • [43] Three-dimensional X-ray micro-computed tomography of cracks in a furnace cycled air plasma sprayed thermal barrier coating
    Ahmadian, Shayan
    Browning, Alyssa
    Jordan, Eric H.
    SCRIPTA MATERIALIA, 2015, 97 : 13 - 16
  • [44] Discrimination of ranitidine hydrochloride crystals using X-ray micro-computed tomography for the evaluation of three-dimensional spatial distribution in solid dosage forms
    Yamamoto, Eiichi
    Takeda, Yoshihiro
    Ando, Daisuke
    Koide, Tatsuo
    Amano, Yuta
    Miyazaki, Shingo
    Miyazaki, Tamaki
    Izutsu, Ken-ichi
    Kanazawa, Hideko
    Goda, Yukihiro
    INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2021, 605
  • [45] Three-dimensional monochromatic x-ray computed tomography using synchrotron radiation
    Saito, T
    Kudo, H
    Takeda, T
    Itai, Y
    Tokumori, K
    Toyofuku, F
    Hyodo, K
    Ando, M
    Nishimura, K
    Uyama, C
    OPTICAL ENGINEERING, 1998, 37 (08) : 2258 - 2268
  • [46] Three-dimensional characterization of powder particles using X-ray computed tomography
    Zhou, Xin
    Dai, Ning
    Cheng, Xiaosheng
    Thompson, Adam
    Leach, Richard
    ADDITIVE MANUFACTURING, 2021, 40
  • [47] Three-dimensional characterization of powder particles using X-ray computed tomography
    Zhou, Xin
    Dai, Ning
    Cheng, Xiaosheng
    Thompson, Adam
    Leach, Richard
    Additive Manufacturing, 2021, 40
  • [48] Three-dimensional observation of mouse tongue muscles using micro-computed tomography
    Hidekazu Aoyagi
    Shin-ichi Iwasaki
    Kenzirou Nakamura
    Odontology, 2015, 103 : 1 - 8
  • [49] Three-dimensional observation of mouse tongue muscles using micro-computed tomography
    Aoyagi, Hidekazu
    Iwasaki, Shin-ichi
    Nakamura, Kenzirou
    ODONTOLOGY, 2015, 103 (01) : 1 - 8
  • [50] Three-dimensional analysis of tumour vascular corrosion casts using stereoimaging and micro-computed tomography
    Folarin, A. A.
    Konerding, M. A.
    Timonen, J.
    Nagl, S.
    Pedley, R. B.
    MICROVASCULAR RESEARCH, 2010, 80 (01) : 89 - 98