A critical review in recent progress of hollow fiber membrane contactors for efficient CO2 separations

被引:32
|
作者
Imtiaz, Aniqa [1 ,2 ]
Othman, Mohd Hafiz Dzarfan [1 ,2 ]
Jilani, Asim [2 ,3 ]
Khan, Imran Ullah [4 ]
Kamaludin, Roziana [1 ,2 ]
Ayub, Muhammad [1 ,2 ]
Samuel, Ojo [1 ,2 ]
Kurniawan, Tonni Agustiono [5 ]
Hashim, NurAwanis [6 ]
Puteh, Mohd Hafiz [7 ]
机构
[1] Univ Teknol Malaysia UTM Johor Bahru, Adv Membrane Technol Res Ctr, Johor Baharu 81310, Kagawa, Malaysia
[2] Univ Teknol Malaysia UTM Johor Bahru, Fac Chem & Energy Engn, Johor Baharu 81310, Kagawa, Malaysia
[3] King Abdulaziz Univ, Ctr Nanotechnol, Jeddah 21589, Saudi Arabia
[4] Inst Appl Sci Technol, Dept Chem & Energy Engn, Pak Austria Fachhochshule, Khanpur Rd, Haripur 22650, Pakistan
[5] Xiamen Univ, Coll Environm & Ecol, Xiamen 361102, Fujian, Peoples R China
[6] Univ Malaya, Dept Chem Engn, Fac Engn, Kuala Lumpur 50603, Malaysia
[7] Univ Teknol Malaysia UTM Johor Bahru, Fac Civil Engn, Fac Engn, Johor Baharu, Kagawa, Malaysia
关键词
OF-THE-ART; POSTCOMBUSTION CARBON CAPTURE; GAS SEPARATION; NATURAL-GAS; FLUE-GAS; MASS-TRANSFER; ABSORPTION TECHNOLOGIES; COPOLYIMIDE MEMBRANES; SURFACE MODIFICATIONS; CHEMICAL ABSORPTION;
D O I
10.1016/j.chemosphere.2023.138300
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Among wide range of membrane-based operations, membrane contactors, as they reify comparatively modern membrane-based mechanism are gaining quite an attention in both pilot and industrial scales. In recent literature, carbon capture is one of the most researched applications of membrane contactors. Membrane contactors have the potential to minimize the energy consumption and capital cost of traditional CO2 absorptions columns. In a membrane contactor, CO2 regeneration can take place below the solvent boiling point, resulting into lower consumption of energy. Various polymeric as well as ceramic membrane materials have been employed in gas liquid membrane contactors along with several solvents including amino acids, ammonia, amines etc. This review article provides detailed introduction of membrane contactors in terms of CO2 removal. It also discusses that the main challenge that is faced by membrane contactors is membrane pore wetting caused by solvent that in turn can reduce the mass transfer coefficient. Other potential challenges such as selection of suitable solvent and membrane pair as well as fouling are also discussed in this review and are followed by potential ways to reduce them. Furthermore, both membrane gas separation and membrane contactor technologies are analysed and compared in this study on the basis of their characteristics, CO2 separation performances and techno economical transvaluation. Consequently, this review provides an opportunity to thoroughly understand the working principle of membrane contactors along its comparison with membrane-based gas separation technology. It also provides a clear understanding of latest innovations in membrane contactor module designs as well as challenges encountered by membrane contactors along with possible solutions to overcome these challenges. Finally, semi commercial and commercial implementation of membrane contactors has been highlighted.
引用
收藏
页数:18
相关论文
共 50 条
  • [41] CO2 capture with membrane contactors
    Falk-Pedersen, O
    Gronvold, MS
    Nokleby, P
    Bjerve, F
    Svendsen, HF
    INTERNATIONAL JOURNAL OF GREEN ENERGY, 2005, 2 (02) : 157 - 165
  • [42] CO2 Capture Using Hollow Fiber Membranes: A Review of Membrane Wetting
    Ibrahim, Mohamed H.
    El-Naas, Muftah H.
    Zhang, Zhien
    Van der Bruggen, Bart
    ENERGY & FUELS, 2018, 32 (02) : 963 - 978
  • [43] Hollow Fiber Membrane Contactors for CO2 Capture: Modeling and Up-Scaling to CO2 Capture for an 800 MWe Coal Power Station
    Kimball, Erin
    Al-Azki, Adam
    Gomez, Adrien
    Goetheer, Earl
    Booth, Nick
    Adams, Dick
    Ferre, Daniel
    OIL & GAS SCIENCE AND TECHNOLOGY-REVUE D IFP ENERGIES NOUVELLES, 2014, 69 (06): : 1047 - 1058
  • [44] Precombustion CO2 Capture in Polymeric Hollow Fiber Membrane Contactors Using Ionic Liquids: Porous Membrane versus Nonporous Composite Membrane
    Dai, Zhongde
    Ansaloni, Luca
    Deng, Liyuan
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2016, 55 (20) : 5983 - 5992
  • [45] Experimental and Numerical Analysis for Improving CO2 Mass Transfer Performance of Blended Solvents in Hollow Fiber Membrane Contactors
    Yin, Yihan
    Gao, Hongxia
    Liang, Zhiwu
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2023, 62 (34) : 13458 - 13469
  • [46] Mathematical modeling for the simultaneous absorption of CO2 and H2S using MEA in hollow fiber membrane contactors
    Faiz, Rami
    Al-Marzouqi, M.
    JOURNAL OF MEMBRANE SCIENCE, 2009, 342 (1-2) : 269 - 278
  • [47] Performance enhancement of hollow fiber membrane contactors for CO2 absorption using MEA-based functionalized nanofluids
    Ahmari, Miad
    Mirfendereski, Seyed Mojtaba
    MICROFLUIDICS AND NANOFLUIDICS, 2024, 28 (09)
  • [48] Experimental study on the separation of CO2 from flue gas using hollow fiber membrane contactors without wetting
    Yan, Shui-ping
    Fang, Meng-Xiang
    Zhang, Wei-Feng
    Wang, Shu-Yuan
    Xu, Zhi-Kang
    Luo, Zhong-Yang
    Cen, Ke-Fa
    FUEL PROCESSING TECHNOLOGY, 2007, 88 (05) : 501 - 511
  • [49] PERFORMANCE OF HOLLOW FIBER MEMBRANE GAS-LIQUID CONTACTORS TO ABSORB CO2 USING DIETHANOLAMINE (DEA) AS A SOLVENT
    Kartohardjono, Sutrasno
    Nata, Pan Ade
    Prasetio, Eko
    Yuliusman
    MAKARA JOURNAL OF TECHNOLOGY, 2009, 13 (02): : 86 - 90
  • [50] Influence of membrane morphology on characteristics of porous hydrophobic PVDF hollow fiber contactors for CO2 stripping from water
    Mansourizadeh, A.
    Ismail, A. F.
    DESALINATION, 2012, 287 : 220 - 227