Smartphone derived anthropometrics: Agreement between a commercially available smartphone application and its parent application intended for use at point-of-care

被引:5
|
作者
Graybeal, Austin J. [1 ,2 ]
Brandner, Caleb F. [1 ]
Compton, Abby T. [1 ]
Swafford, Sydney H. [1 ]
Henderson, Alex [1 ]
Aultman, Ryan [1 ]
Vallecillo-Bustos, Anabelle [1 ]
Stavres, Jon [1 ]
机构
[1] Univ Southern Mississippi, Sch Kinesiol & Nutr, Hattiesburg, MS USA
[2] Univ Southern Mississippi, Coll Educ & Human Sci, Sch Kinesiol Nutr, Hattiesburg, MS 39406 USA
关键词
Anthropometrics; Smartphone; 3D scanning; Body composition; Body fat; Body circumference;
D O I
10.1016/j.clnesp.2023.11.021
中图分类号
R15 [营养卫生、食品卫生]; TS201 [基础科学];
学科分类号
100403 ;
摘要
Background & Aims: Smartphone applications can now automate body composition and anthropometric measurements remotely, prompting applications intended for use at point-of-care to provide commercially available smartphone applications intended for personal use. However, the agreement between such anthropometrics remain unclear.Methods: A total of 123 apparently healthy participants (F: 69; M: 54; age: 28.1 +/- 11.3; BMI: 26.9 +/- 5.9) completed consecutive body composition scans using a 3D smartphone application intended for personal use (MeThreeSixty; MTS) and it stationary counterpart intended for use in practice (Mobile Fit Booth; MFB). Agreement between devices were evaluated using root mean square error (RMSE), Bland-Altman analyses, and linear regression for all measurements, and additional equivalence testing was conducted for all circumference and limb length comparisons.Results: When evaluated against the MFB, MTS significantly overestimated all measurements other than waist circumference (p = 0.670) using paired t-tests. RMSE was 2.5% for body fat percentage (BF%), 0.64-3.74 cm for all body circumferences, 0.71-2.3 kg for all lean mass estimates, and 126-659 cm(2) and 608-4,672 cm(3) across all body surface area and body volume estimates, respectively. BF% was the only body composition estimate that did not demonstrate proportional bias (p = 0.221). Circumferences of the chest, shoulder, biceps, forearm, and ankle all demonstrated proportional bias (all coefficients: p <0.050), but only chest, shoulder, and arm circumferences did not demonstrate equivalence. Arm surface area (p < 0.001) and arm (p = 0.002) and leg volumes (p = 0.004) were the only body surface area and volume estimates to reveal proportional biases.Conclusions: These findings demonstrate the agreement between 3D anthropometric applications intended for clinical and personal use, particularly for whole-body composition estimates and clinically meaningful body circumferences. Given the advantages of commercially available remote applications, practitioners and consumers may consider using this method in place of those intended for clinical practice, but should express caution when overestimation is a concern.(c) 2023 European Society for Clinical Nutrition and Metabolism. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:107 / 112
页数:6
相关论文
共 50 条
  • [21] Quantification of colorimetric isothermal amplification on the smartphone and its open-source app for point-of-care pathogen detection
    Huynh Quoc Nguyen
    Van Dan Nguyen
    Hau Van Nguyen
    Tae Seok Seo
    Scientific Reports, 10
  • [22] Paper-Based Versatile Surface-Enhanced Raman Spectroscopy Chip with Smartphone-Based Raman Analyzer for Point-of-Care Application
    Zeng, Fanyu
    Duan, Wendi
    Zhu, Bin
    Mu, Taotao
    Zhu, Lianqing
    Guo, Jinhong
    Ma, Xing
    ANALYTICAL CHEMISTRY, 2019, 91 (01) : 1064 - 1070
  • [23] Routine use of point-of-care tests: usefulness and application in clinical microbiology
    Clerc, O.
    Greub, G.
    CLINICAL MICROBIOLOGY AND INFECTION, 2010, 16 (08) : 1054 - 1061
  • [24] Muscle ultrasound and its application to point-of-care ultrasonography: a narrative review
    Nagae, Masaaki
    Umegaki, Hiroyuki
    Yoshiko, Akito
    Fujita, Kosuke
    ANNALS OF MEDICINE, 2023, 55 (01) : 190 - 197
  • [25] ASSOCIATION BETWEEN NICOTINE DEPENDENCE, SMARTPHONE USE, AND EXPECTED SMOKING CESSATION APPLICATION USAGE
    Kim, Woo Jin
    Kwon, Oh Beom
    Park, Sang Won
    CHEST, 2024, 166 (04) : 6244A - 6244A
  • [26] STUDENT'S AWARENESS AND USE OF SMARTPHONE APPLICATIONS TO ACCESS THE AVAILABLE SERVICES AT UNIVERSITY OF BAHRAIN LIBRARY: A PROPOSED APPLICATION
    Abdulrazzaq, Amera H.
    Al-Ani, Mayyadah
    10TH INTERNATIONAL CONFERENCE OF EDUCATION, RESEARCH AND INNOVATION (ICERI2017), 2017, : 26 - 35
  • [27] Fifteen-Minute Detection of Streptococcus pyogenes in Throat Swabs by Use of a Commercially Available Point-of-Care PCR Assay
    Uhl, James R.
    Patel, Robin
    JOURNAL OF CLINICAL MICROBIOLOGY, 2016, 54 (03) : 815 - 815
  • [28] Smartphone-assisted detection of monocrotophos pesticide using a portable nano-enabled chromagrid-lightbox system towards point-of-care application
    Shrikrishna, Narlawar Sagar
    Kaushik, Ajeet
    Gandhi, Sonu
    CHEMOSPHERE, 2023, 330
  • [29] A lanthanide-based magnetic nanosensor as an erasable and visible platform for multi-color point-of-care detection of multiple targets and the potential application by smartphone
    Xu, Jun
    Shen, Xiao-Ke
    Jia, Lei
    Cao, Jian-Liang
    Wang, Yan
    Zhao, Xiao-Lei
    Bi, Ning
    Guo, Sheng-Li
    Ma, Tian-Yi
    JOURNAL OF MATERIALS CHEMISTRY B, 2019, 7 (05) : 734 - 743
  • [30] Towards the use of a smartphone imaging-based tool for point-of-care detection of asymptomatic low-density malaria parasitaemia
    Colbert, Ashlee J.
    Co, Katrina
    Lima-Cooper, Giselle
    Lee, Dong Hoon
    Clayton, Katherine N.
    Wereley, Steven T.
    John, Chandy C.
    Linnes, Jacqueline C.
    Kinzer-Ursem, Tamara L.
    MALARIA JOURNAL, 2021, 20 (01)