Effect of Fibres on Physico-Mechanical Properties of Bulk-Fill Resin Composites

被引:3
|
作者
Alshabib, Abdulrahman [1 ]
Silikas, Nick [2 ]
Algamaiah, Hamad [1 ]
Alayad, Abdullah S. [1 ]
Alawaji, Rahaf [3 ]
Almogbel, Shaikha [3 ]
Aldosari, Ahad [3 ]
Alhotan, Abdulaziz [4 ]
机构
[1] King Saud Univ, Coll Dent, Dept Restorat Dent, POB 60169, Riyadh 11545, Saudi Arabia
[2] Univ Manchester, Fac Biol Med & Hlth, Div Dent, Manchester M13 9PL, England
[3] King Saud Univ, Coll Dent, Dent Interns, POB 60169, Riyadh 11545, Saudi Arabia
[4] King Saud Univ, Coll Appl Med Sci, Dept Dent Hlth, POB 10219, Riyadh 12372, Saudi Arabia
关键词
resin composites; fibre reinforcement; water storage; flexural strength; absorption; solubility; DENTAL COMPOSITES; FLEXURAL STRENGTH; BIS-GMA; WATER; POLYMERIZATION; MODULUS; RESTORATIONS; DEGRADATION; MONOMERS; ADHESION;
D O I
10.3390/polym15163452
中图分类号
O63 [高分子化学(高聚物)];
学科分类号
070305 ; 080501 ; 081704 ;
摘要
Objective: To measure the flexural strength (FS) of bulk-fill resin composites and assess their long-term water absorption and solubility properties with and without the inclusion of short glass fibres. Methods: One resin composite, everX Flow with fibres, and four commercially available bulk-fill composites without fibres, namely, PALFIQUE, Activa, SDR Plus, and Filtek Bulk Fill One, were tested. Six specimens (2 x 2 x 25 mm) were fabricated for each material and stored in water for 1 day and 30 days to measure the flexural strength using a three-point bending test. To evaluate water absorption and solubility, circular disks measuring 15 x 2 mm (n = 5) were immersed in water for 60 days, and their weights were recorded periodically. After 60 days, the specimens were dried for an additional 21 days to determine solubility. Results: Flexural strength values ranged from 101.7 to 149.1 MPa. Significant distinctions were observed among the resin composites at the onset of the study (p < 0.05). The highest FS value was identified in everX Flow, while ACT exhibited the lowest (p < 0.05). However, the flexural strength values exhibited a significant decrease with increased storage time (p < 0.05), except for ACT, which demonstrated a noteworthy increase. Concerning water absorption and solubility, ACT displayed the highest absorption, while the range of solubility varied from 0.88 to 5.8 mu g/mm(3). ACT also had the highest solubility, whereas everX Flow exhibited negative solubility. Significance: The addition of short fibres, along with potential differences in matrix composition, enhanced the flexural strength of everX Flow. However, the substantial reduction in flexural strength observed in everX Flow and SDR following exposure to water corroborates the manufacturers' recommendation to apply a conventional resin composite cap on these materials.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] New generation bulk-fill resin composites: Effects on mechanical strength and fracture reliability
    de Lacerda, Luciano Rosa
    Bossardi, Mayara
    Silveira Mitterhofer, Weronica Jaernevay
    de Carvalho, Fabiola Galbiatti
    Carlo, Hugo Lemes
    Piva, Evandro
    Munchow, Eliseu Aldrighi
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2019, 96 : 214 - 218
  • [22] Effect of Shortened Light-Curing Modes on Bulk-Fill Resin Composites
    Sampaio, C. S.
    Pizarro, P. G.
    Atria, P. J.
    Hirata, R.
    Giannini, M.
    Mahn, E.
    OPERATIVE DENTISTRY, 2020, 45 (05) : 496 - 505
  • [23] The Effect of Gravity on Marginal Integrity of Different Flowable Bulk-Fill Resin Composites
    Baltacioglu, Ismail Hakki
    Demirel, Gulbike
    Kolsuz, Mehmet Eray
    Orhan, Kaan
    MEDICINA-LITHUANIA, 2024, 60 (03):
  • [24] Effect of Light Curing Distance on Microhardness Profiles of Bulk-Fill Resin Composites
    Hasanain, Fatin A.
    Nassar, Hani M.
    Ajaj, Reem A.
    POLYMERS, 2022, 14 (03)
  • [25] Mechanical properties of bulk-fill resin composites with single increment up to 4 mm: A novel mechanical strength test
    Yang, Jiaxue
    Chen, Ying
    Meng, Hongliang
    Shen, Jiadi
    Liao, Mengyuan
    Xie, Haifeng
    AMERICAN JOURNAL OF DENTISTRY, 2023, 36 (02): : 101 - 108
  • [26] Surface Microhardness of Bulk-Fill Resin Composites Handled With Gloves
    Berto-Inga, Julissa
    Santander-Rengifo, Flor
    Ladera-Castaneda, Marysela
    Lopez-Gurreonero, Carlos
    Perez-Vargas, Antonieta Castro
    Cornejo-Pinto, Alberto
    Cervantes-Ganoza, Luis
    Cayo-Rojas, Cesar
    INTERNATIONAL DENTAL JOURNAL, 2023, 73 (04) : 489 - 495
  • [27] Curing profile of bulk-fill resin-based composites
    Li, Xin
    Pongprueksa, Pong
    Van Meerbeek, Bart
    De Munck, Jan
    JOURNAL OF DENTISTRY, 2015, 43 (06) : 664 - 672
  • [28] Effect of different curing protocols on the mechanical properties of low-viscosity bulk-fill composites
    Nicoleta Ilie
    Katharina Stark
    Clinical Oral Investigations, 2015, 19 : 271 - 279
  • [29] Effect of whitening mouthrinses on bulk-fill composites
    Berger, Sandrine Bittencourt
    Petri, Zanelli
    Hass, Viviane
    Guiraldo, Ricardo Danil
    Favaro, Jaqueline Costa
    Lopes, Murilo Baena
    Miranda Gonzalez, Alejandra Hortencia
    AMERICAN JOURNAL OF DENTISTRY, 2019, 32 (05): : 235 - 239
  • [30] The Effect of Inorganic Filler Content on the Properties of BPA-Free Bulk-Fill Dental Resin Composites
    Deng, Huilin
    Liu, Fang
    He, Jingwei
    MATERIALS, 2024, 17 (20)