Flexible composite suppression method for ground arc in resonant grounding system

被引:4
|
作者
You, Jianzhang [1 ,2 ]
Guo, Moufa [1 ,2 ]
Zheng, Zeyin [1 ,2 ]
Liu, Xinbin [1 ]
机构
[1] Fuzhou Univ, Sch Elect Engn & Automat, Fuzhou, Peoples R China
[2] Fujian Prov Univ, Engn Res Ctr Smart Distribut Grid Equipment, Fuzhou, Peoples R China
基金
中国国家自然科学基金;
关键词
LOCATION; PHASE; COIL;
D O I
10.1049/hve2.12354
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A current-voltage composite controller for an arc suppression inverter is designed. The current and voltage at the fault point are reduced by injecting current and regulating the neutral point voltage to completely eliminate the risk of fire and overvoltage caused by a single-line-to-ground fault arc. A cascaded inverter is used, and the effects of the ground parameter measurement, line impedance voltage drop, harmonic current and arc suppression coil on the current control, voltage control and composite control methods are analysed and compared. Finally, software simulations and industrial prototype experiments show that the proposed composite control method is effective and less affected by ground parameter measurement and line impedance voltage drop and has better adaptability.
引用
收藏
页码:1296 / 1305
页数:10
相关论文
共 50 条
  • [41] Analytical method for pile composite ground under flexible foundation
    Lu, Wenzhi
    Yu, Jianlin
    Gong, Xiaonan
    Yanshilixue Yu Gongcheng Xuebao/Chinese Journal of Rock Mechanics and Engineering, 2010, 29 (02): : 401 - 408
  • [42] Review of Flexible Arc Suppression Technology for Single-phase-to-ground Fault in Distribution Networks
    Guo M.
    You J.
    Zheng Z.
    Gaodianya Jishu/High Voltage Engineering, 2023, 49 (10): : 4232 - 4246
  • [43] Composite Grounding Application of Transmission Line Tower with Flexible Graphite Grounding Material
    Liu, Hongtao
    Zhang, Lei
    Xiong, Jia
    Cui, Zhenxing
    Yang, Qi
    2ND INTERNATIONAL CONFERENCE ON DESIGN, MATERIALS, AND MANUFACTURING, 2017, 220
  • [44] Unreal grounding identification and comprehensive line selection for resonant grounding system
    Shu H.
    Dianli Zidonghua Shebei/Electric Power Automation Equipment, 2016, 36 (06): : 122 - 129
  • [45] Residual current analysis by applying ground fault transfer arc suppression method
    Yu X.
    Ouyang J.
    Qin L.
    International Journal of Electrical Engineering, 2018, 25 (06): : 205 - 214
  • [46] Simulation Study on Lightning Impulse Characteristics of Flexible Graphite Composite Grounding Materials Applied to Grounding Grid of Power System
    Hu, Yuanchao
    Huang, Tao
    An, Yunzhu
    Feng, Jianyuan
    Cheng, Meng
    Xie, Hongping
    Shen, Wentao
    Du, Changqing
    FRONTIERS IN ENERGY RESEARCH, 2022, 10
  • [47] Active Location Method for Single-Line-to-Ground Fault of Flexible Grounding Distribution Networks
    Lin, Jiahao
    Guo, Moufa
    Zheng, Zeyin
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2023, 72
  • [48] Novel arc suppression method for single-phase grounding fault considering line voltage drop
    Ding, Jingming
    Zou, Guibin
    Zhou, Chenghan
    Wen, Xuhui
    Xu, Chunhua
    Sun, Weijie
    ELECTRICAL ENGINEERING, 2023, 105 (06) : 3469 - 3479
  • [49] Novel arc suppression method for single-phase grounding fault considering line voltage drop
    Jingming Ding
    Guibin Zou
    Chenghan Zhou
    Xuhui Wen
    Chunhua Xu
    Weijie Sun
    Electrical Engineering, 2023, 105 : 3469 - 3479
  • [50] SUPPRESSION OF OSCILLATIONS IN GODUNOVS METHOD FOR A RESONANT NONSTRICTLY HYPERBOLIC SYSTEM
    LIN, LW
    TEMPLE, B
    WANG, JH
    SIAM JOURNAL ON NUMERICAL ANALYSIS, 1995, 32 (03) : 841 - 864