Field Dynamic Balancing for Magnetically Suspended Turbomolecular Pump

被引:1
|
作者
Chen, Qi [1 ]
Li, Jinlei [2 ]
机构
[1] Air Force Engn Univ, Aeronaut Engn Sch, Xian 710038, Peoples R China
[2] Sci & Technol Space Phys Lab, Beijing 100076, Peoples R China
基金
中国国家自然科学基金;
关键词
field dynamic balancing; active magnetic bearing; rigid rotor; ROTOR; VIBRATION; SUPPRESSION; REDUCTION;
D O I
10.3390/s23136168
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A field dynamic balancer is crucial to the applications of magnetically suspended turbomolecular pumps. Therefore, this paper presents a novel field dynamic balancing method based on autocentering control mode without any additional instrumentation. Firstly, the dynamics of the active magnetic bearing rotor system with unbalance are modeled. Through model analysis, it was found that making the rotor rotate around the geometric axis can improve the accuracy of dynamic balancing. Secondly, the relationship between the correcting masses and the synchronous currents based on the influence coefficient method is established. Then, an autocentering controller is designed to make the rotor rotate around the geometric axis. The synchronous currents can be detected and extracted by the current transducers to calculate the unbalance correction mass. Finally, the experimental results show that this novel field dynamic balancing method can effectively eliminate the majority of rotor unbalance. Compared with the original unbalance of a rotor, the synchronous current in the A-end has been reduced by 71.4% and the synchronous current in the B-end, by 90.8% with the proposed method.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] A new magnetically suspended centrifugal pump: In vitro and preliminary in vivo assessment
    Park, CH
    Nishimura, K
    Akamatsu, T
    Tsukiya, T
    Matsuda, K
    Ban, T
    ARTIFICIAL ORGANS, 1996, 20 (02) : 128 - 131
  • [32] Numerical investigation on hydrodynamics and biocompatibility of a magnetically suspended axial blood pump
    Zhu, Xianran
    Zhang, Mingyuan
    Zhang, Genguang
    Liu, Haonan
    ASAIO JOURNAL, 2006, 52 (06) : 624 - 629
  • [33] In vivo and in vitro evaluation of the pulsatile mode of a magnetically suspended centrifugal pump
    Kono, S
    Nishimura, K
    Yamada, T
    Oonishi, T
    Tsukiya, T
    Akamatsu, T
    Ban, T
    ASAIO JOURNAL, 1997, 43 (05) : M580 - M584
  • [34] Development of the radiation-hardened magnetically suspended compound molecular pump
    Wada, Kaoru
    Inohara, Takashi
    Iguchi, Masashi
    Ogiwara, Norio
    Mio, Keigo
    Nakayama, Hironori
    Shinku/Journal of the Vacuum Society of Japan, 2007, 50 (06) : 452 - 454
  • [35] Development of the radiation-hardened Magnetically Suspended Compound Molecular Pump
    Wada, Kaoru
    Inohara, Takashi
    Yoshida, Motoo
    Yamato, Yukio
    Nakayasu, Tatsuo
    Iguchi, Masashi
    Hikichi, Yusuke
    Ogiwara, Norio
    Mio, Keigo
    VACUUM, 2009, 84 (05) : 699 - 704
  • [36] INFLUENCE OF CLEARANCES ON TURBOMOLECULAR PUMP PERFORMANCE
    DESIMON, M
    VACUUM, 1990, 41 (7-9) : 2021 - 2024
  • [37] NEW CONCEPTS IN TURBOMOLECULAR PUMP DESIGN
    HABLANIAN, MH
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY A-VACUUM SURFACES AND FILMS, 1993, 11 (04): : 1614 - 1619
  • [38] Influence of Blade Flexibility on the Dynamic Response Simulation of a Turbomolecular Pump on Magnetic Bearings
    Moreira, Alysson Bruno Barbosa
    Thouverez, Fabrice
    JOURNAL OF ENGINEERING FOR GAS TURBINES AND POWER-TRANSACTIONS OF THE ASME, 2020, 142 (04):
  • [39] Balancing of Turbomolecular Pumps: Modal Balancing Approach and Experimental Results
    Quartarone, Carmelo
    Beqari, Julian
    Detoni, Joaquim Girardello
    Cometti, Flavio
    Emelli, Enrico
    PROCEEDINGS OF THE 10TH INTERNATIONAL CONFERENCE ON ROTOR DYNAMICS - IFTOMM, VOL. 4, 2019, 63 : 119 - 128
  • [40] A numerical study of the performance of a turbomolecular pump
    Hwang, YK