Comparative Effectiveness of Percutaneous Microaxial Left Ventricular Assist Device vs Intra-Aortic Balloon Pump or No Mechanical Circulatory Support in Patients With Cardiogenic Shock

被引:25
|
作者
Almarzooq, Zaid I. I. [1 ,2 ]
Song, Yang [1 ]
Dahabreh, Issa J. J. [1 ,3 ,4 ]
Kochar, Ajar [1 ,2 ]
Ferro, Enrico G. G. [1 ]
Secemsky, Eric A. A. [1 ]
Major, Jacqueline M. M. [5 ]
Farb, Andrew [6 ]
Wu, Changfu [6 ]
Zuckerman, Bram B. [6 ]
Yeh, Robert W. W. [1 ,7 ]
机构
[1] Beth Israel Deaconess Med Ctr, Richard A & Susan F Smith Ctr Outcomes Res Cardiol, Div Cardiol, Boston, MA 02215 USA
[2] Brigham & Womens Hosp, Div Cardiol, Boston, MA USA
[3] Harvard TH Chan Sch Publ Hlth, CAUSALab, Boston, MA USA
[4] Harvard TH Chan Sch Publ Hlth, Dept Epidemiol & Biostat, Boston, MA USA
[5] US FDA, Off Clin Evidence & Anal, Ctr Devices & Radiol Hlth, Silver Spring, MD USA
[6] US FDA, Off Cardiovasc Devices, Ctr Devices & Radiol Hlth, Silver Spring, MD USA
[7] Beth Israel Deaconess Med Ctr, Richard A & Susan F Smith Ctr Outcomes Res Cardio, 375 Longwood Ave, 4th Floor, Boston, MA 02215 USA
关键词
RANDOMIZED-TRIAL; TECHNOLOGY;
D O I
10.1001/jamacardio.2023.1643
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
IMPORTANCE Recent studies have produced inconsistent findings regarding the outcomes of the percutaneous microaxial left ventricular assist device (LVAD) during acute myocardial infarction with cardiogenic shock (AMICS). OBJECTIVE To compare the percutaneous microaxial LVAD vs alternative treatments among patients presenting with AMICS using observational analyses of administrative data. DESIGN, SETTING, AND PARTICIPANTS This comparative effectiveness research study used Medicare fee-for-service claims of patients admitted with AMICS undergoing percutaneous coronary intervention from October 1, 2015, through December 31, 2019. Treatment strategies were compared using (1) inverse probability of treatment weighting to estimate the effect of different baseline treatments in the overall population; (2) instrumental variable analysis to determine the effectiveness of the percutaneous microaxial LVAD among patients whose treatment was influenced by cross-sectional institutional practice patterns; (3) an instrumented difference-in-differences analysis to determine the effectiveness of treatment among patients whose treatment was influenced by longitudinal changes in institutional practice patterns; and (4) a grace period approach to determine the effectiveness of initiating the percutaneous microaxial LVAD within 2 days of percutaneous coronary intervention. Analysis took place between March 2021 and December 2022. INTERVENTIONS Percutaneous microaxial LVAD vs alternative treatments (including medical therapy and intra-aortic balloon pump). MAIN OUTCOMES AND MEASURES Thirty-day all-cause mortality and readmissions. RESULTS Of 23 478 patients, 14 264 (60.8%) were male and the mean (SD) age was 73.9 (9.8) years. In the inverse probability of treatment weighting analysis and grace period approaches, treatment with percutaneous microaxial LVAD was associated with a higher risk-adjusted 30-day mortality (risk difference, 14.9%; 95% CI, 12.9%-17.0%). However, patients receiving the percutaneous microaxial LVAD had a higher frequency of factors associated with severe illness, suggesting possible confounding by measures of illness severity not available in the data. In the instrumental variable analysis, 30-day mortality was also higher with percutaneous microaxial LVAD, but patient and hospital characteristics differed across levels of the instrumental variable, suggesting possible confounding by unmeasured variables (risk difference, 13.5%; 95% CI, 3.9%-23.2%). In the instrumented difference-in-differences analysis, the association between the percutaneous microaxial LVAD and mortality was imprecise, and differences in trends in characteristics between hospitals with different percutaneous microaxial LVAD use suggested potential assumption violations. CONCLUSIONS In observational analyses comparing the percutaneous microaxial LVAD to alternative treatments among patients with AMICS, the percutaneous microaxial LVADwas associated with worse outcomes in some analyses, while in other analyses, the association was too imprecise to draw meaningful conclusions. However, the distribution of patient and institutional characteristics between treatment groups or groups defined by institutional differences in treatment use, including changes in use over time, combined with clinical knowledge of illness severity factors not captured in the data, suggested violations of key assumptions that are needed for valid causal inference with different observational analyses. Randomized clinical trials of mechanical support devices will allow valid comparisons across candidate treatment strategies and help resolve ongoing controversies.
引用
收藏
页码:744 / 754
页数:11
相关论文
共 50 条
  • [31] Percutaneous left ventricular assist device vs. intra-aortic balloon pump in patients with severe left ventricular dysfunction undergoing cardiovascular intervention: A meta-analysis
    Hu Fang-Bin
    Cui Lian-Qun
    慢性疾病与转化医学(英文), 2018, 4 (04) : 260 - 267
  • [32] Percutaneous left ventricular assist devices versus intra-aortic balloon pump counterpulsation for treatment of cardiogenic shock: a meta-analysis of controlled trials
    Cheng, J. M.
    Den Uil, C. A.
    Hoeks, S. E.
    Van der Ent, M.
    Jewbali, L. S. D.
    Van Domburg, R. T.
    Serruys, P. W.
    EUROPEAN HEART JOURNAL, 2009, 30 : 389 - 389
  • [33] Complications from percutaneous-left ventricular assist devices versus intra-aortic balloon pump in acute myocardial infarction-cardiogenic shock
    Vallabhajosyula, Saraschandra
    Subramaniam, Anna, V
    Murphree, Dennis H., Jr.
    Patlolla, Sri Harsha
    Ya'Qoub, Lina
    Kumar, Vinayak
    Verghese, Dhiran
    Cheungpasitporn, Wisit
    Jentzer, Jacob C.
    Sandhu, Gurpreet S.
    Gulati, Rajiv
    Shah, Nilay D.
    Gersh, Bernard J.
    Holmes, David R., Jr.
    Bell, Malcolm R.
    Barsness, Gregory W.
    PLOS ONE, 2020, 15 (08):
  • [34] PERCUTANEOUS LEFT VENTRICULAR ASSIST DEVICES VERSUS INTRA-AORTIC BALLOON PUMP COUNTERPULSATION FOR TREATMENT OF CARDIOGENIC SHOCK: A META-ANALYSIS OF CONTROLLED TRIALS
    Cheng, J.
    den Uil, C.
    Hoeks, S.
    van der Ent, M.
    Jewbali, L.
    van Domburg, R.
    Serruys, P.
    INTENSIVE CARE MEDICINE, 2009, 35 : 109 - 109
  • [35] Extracorporeal membrane oxygenation and microaxial left ventricular assist device in cardiogenic shock: Choosing the right mechanical circulatory support to improve outcomes
    Dagher, Olina
    Noly, Pierre-Emmanuel
    Ali, Walid Ben
    Bouabdallaoui, Nadia
    Geicu, Lucian
    Lamanna, Roxanne
    Malhi, Pavan
    Romero, Elizabeth
    Ducharme, Anique
    Demers, Philippe
    Lamarche, Yoan
    JTCVS OPEN, 2023, 13 : 200 - 213
  • [36] Hemodynamic Effects of Intra-Aortic Balloon Pump as a Bridge to Durable Left Ventricular Assist Device
    Brown, M.
    Lekan, A.
    Hofmeyer, M.
    Rodrigo, M.
    Kadakkal, A.
    Lam, P. H.
    Krishnan, M.
    Afari-Armah, N.
    Rao, S.
    Gupta, R.
    Alassar, A.
    Molina, E.
    Sheikh, F.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2023, 42 (04): : S407 - S407
  • [37] Left Axillary Artery Intra-Aortic Balloon Pump Provides Safe, Ambulatory Support in Patients With Cardiogenic Shock
    Pacha, Homam Moussa
    Alraies, M. Chadi
    Soud, Mohamad
    Bernardo, Nelson L.
    CIRCULATION, 2017, 136
  • [38] Percutaneous assist devices vs. intra-aortic balloon pump for cardiogenic shock: evidence under construction vs. expert opinion
    Cheng, Jin M.
    den Uil, Corstiaan A.
    EUROPEAN HEART JOURNAL, 2010, 31 (04) : 502 - 503
  • [39] Evolution in the use of intra-aortic balloon pump in patients with cardiogenic shock
    Xavier Fontes, A.
    Montenegro Sa, F.
    Passos Silva, M.
    Caeiro, D.
    Dias, A.
    Santos, L.
    Rodrigues, J. A.
    Tavares, A.
    Braga, P.
    EUROPEAN HEART JOURNAL, 2018, 39 : 962 - 963
  • [40] INTRA-AORTIC BALLOON PUMP ASSIST FOR CARDIOGENIC-SHOCK AFTER CARDIOPULMONARY BYPASS
    BUCKLEY, MJ
    AUSTEN, WG
    CRAVER, JM
    DAGGETT, WM
    GOLD, HK
    MUNDTH, ED
    CIRCULATION, 1972, 46 (04) : 76 - &