Diagnostic accuracy of ultrasound in the diagnosis of Placenta accreta spectrum: systematic review and meta-analysis

被引:9
|
作者
Maged, Ahmed M. [1 ]
El-Mazny, Akmal [1 ]
Kamal, Nada [1 ]
Mahmoud, Safaa I. [1 ]
Fouad, Mona [1 ]
El-Nassery, Noura [1 ]
Kotb, Amal [2 ]
Ragab, Wael S. [3 ]
Ogila, Asmaa I. [1 ]
Metwally, Ahmed A. [1 ]
Lasheen, Yossra [1 ]
Fahmy, Radwa M. [1 ]
Katta, Maha [2 ]
Shaeer, Eman K. [1 ]
Salah, Noha [1 ]
机构
[1] Cairo Univ, Kasr Al Ainy Hosp, Dept Obstet & Gynecol, Giza, Egypt
[2] Beni Suef Univ, Dept Obstet & Gynecol, Bani Suwayf, Egypt
[3] Fayoum Univ, Dept Obstet & Gynecol, Al Fayyum, Egypt
关键词
Morbidly adherent placenta; Placenta accreta; Placenta accreta spectrum; Placenta increta; Placenta percreta; Prenatal ultrasound diagnosis; PRENATAL-DIAGNOSIS; ANTENATAL DIAGNOSIS; PREVIA-ACCRETA; DOPPLER ULTRASONOGRAPHY; MATERNAL MORBIDITY; RISK-FACTORS; GRAY-SCALE; MRI; SONOGRAPHY; WOMEN;
D O I
10.1186/s12884-023-05675-6
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
ObjectiveTo evaluate the diagnostic accuracy of ultrasound and in the diagnosis of Placenta accreta spectrum (PAS).Data sourcesScreening of MEDLINE, CENTRAL, other bases from inception to February 2022 using the keywords related to placenta accreta, increta, percreta, morbidly adherent placenta, and preoperative ultrasound diagnosis.Study eligibility criteriaAll available studies- whether were prospective or retrospective- including cohort, case control and cross sectional that involved prenatal diagnosis of PAS using 2D or 3D ultrasound with subsequent pathological confirmation postnatal were included. Fifty-four studies included 5307 women fulfilled the inclusion criteria, PAS was confirmed in 2025 of them.Study appraisal and synthesis methodsExtracted data included settings of the study, study type, sample size, participants characteristics and their inclusion and exclusion criteria, Type and site of placenta previa, Type and timing of imaging technique (2D, and 3D), severity of PAS, sensitivity and specificity of individual ultrasound criteria and overall sensitivity and specificity.ResultsThe overall sensitivity was 0.8703, specificity was 0.8634 with -0.2348 negative correlation between them. The estimate of Odd ratio, negative likelihood ratio and positive likelihood ratio were 34.225, 0.155 and 4.990 respectively.The overall estimates of loss of retroplacental clear zone sensitivity and specificity were 0.820 and 0.898 respectively with 0.129 negative correlation. The overall estimates of myometrial thinning, loss of retroplacental clear zone, the presence of bridging vessels, placental lacunae, bladder wall interruption, exophytic mass, and uterovesical hypervascularity sensitivities were 0.763, 0.780, 0.659, 0.785, 0.455, 0.218 and 0.513 while specificities were 0.890, 0.884, 0.928, 0.809, 0.975, 0.865 and 0.994 respectively.ConclusionsThe accuracy of ultrasound in diagnosis of PAS among women with low lying or placenta previa with previous cesarean section scars is high and recommended in all suspected cases.
引用
收藏
页数:17
相关论文
共 50 条
  • [42] Comparative analysis of ultrasound and MRI in the diagnosis of placenta accreta spectrum
    Barzilay, Eran
    Brandt, Benny
    Gilboa, Yinon
    Kassif, Eran
    Achiron, Reuven
    Raviv-Zilka, Lisa
    Katorza, Eldad
    JOURNAL OF MATERNAL-FETAL & NEONATAL MEDICINE, 2022, 35 (21): : 4056 - 4059
  • [43] Obesity and risk of placenta accreta spectrum: A meta-analysis
    Jenabi, Ensiyeh
    Najafi-Vosough, Roya
    Nazari, Arshia
    OPEN MEDICINE, 2024, 19 (01):
  • [44] Hypertension in pregnancy as a risk factor for placenta accreta spectrum: a systematic review incorporating a network meta-analysis
    Lingli Li
    Luping Liu
    YuYue Xu
    Archives of Gynecology and Obstetrics, 2023, 307 : 1323 - 1329
  • [45] Hypertension in pregnancy as a risk factor for placenta accreta spectrum: a systematic review incorporating a network meta-analysis
    Li, Lingli
    Liu, Luping
    Xu, YuYue
    ARCHIVES OF GYNECOLOGY AND OBSTETRICS, 2023, 307 (05) : 1323 - 1329
  • [46] Chest ultrasound for the diagnosis of paediatric pulmonary diseases: a systematic review and meta-analysis of diagnostic test accuracy
    Heuvelings, Charlotte C.
    Belard, Sabine
    Familusi, Mary A.
    Spijker, Rene
    Grobusch, Martin P.
    Zar, Heather J.
    BRITISH MEDICAL BULLETIN, 2019, 129 (01) : 35 - 51
  • [47] Diagnostic accuracy of lung ultrasound for pulmonary embolism: a systematic review and meta-analysis
    Squizzato, A.
    Rancan, E.
    Dentali, F.
    Bonzini, M.
    Guasti, L.
    Steidl, L.
    Mathis, G.
    Ageno, W.
    JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2013, 11 (07) : 1269 - 1278
  • [48] Diagnostic accuracy of cardiopulmonary ultrasound for pulmonary embolism: A systematic review and meta-analysis
    Cao, Jingli
    Sun, Junjie
    Wang, Yuanyuan
    Wang, Lihong
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2022, 39 (02): : 185 - 193
  • [49] Diagnostic accuracy of lung ultrasound for pulmonary embolism: a systematic review and meta-analysis
    Squizzato, A.
    Rancan, E.
    Dentali, F.
    Bonzini, M.
    Guasti, L.
    Steidl, L.
    Mathis, G.
    Ageno, W.
    JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2013, 11 : 601 - 601
  • [50] Diagnostic accuracy of ultrasound for small bowel obstruction: A systematic review and meta-analysis
    Lin, You-Cheng
    Yu, Yi-Chung
    Huang, Yu-Ting
    Wu, Yun-Yu
    Wang, Ting-Cheng
    Huang, Wen-Cheng
    Yang, Meng-Duo
    Hsu, Yuan-Pin
    EUROPEAN JOURNAL OF RADIOLOGY, 2021, 136