A Study of a New Certified Reference Material for Accurate Determination of the Main Fusarium Mycotoxins in Whole-Wheat Flour

被引:0
|
作者
Li, Li [1 ]
Li, Peng [1 ]
Wu, Yu [1 ]
Ye, Jin [1 ]
Li, Zongwang [1 ,2 ]
Wang, Songxue [1 ]
机构
[1] Acad Natl Food & Strateg Reserv Adm, Beijing 100037, Peoples R China
[2] Univ Shanghai Sci & Technol, Sch Hlth Sci & Engn, Shanghai 200093, Peoples R China
基金
国家重点研发计划;
关键词
certified reference material; Fusarium mycotoxins in whole-wheat flour; ID-LC/MS/MS; characterization; homogeneity and stability study; uncertainty evaluation; DEOXYNIVALENOL; ZEARALENONE; FRACTIONS; PROVINCE; CEREALS; BLIGHT; IRON;
D O I
10.3390/foods12234358
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
Matrix certified reference materials (CRMs) play a critical role in analytical method validation and the assurance of reliable measurement results. A certified reference material (GBW(E)100813) for whole-wheat flour was developed to ensure an accurate and reliable measurement of the main Fusarium mycotoxins (deoxynivalenol (DON), nivalenol (NIV), deoxynivalenol-3-glucoside (DON-3G), and zearalenone (ZEN)). CRM candidates were prepared using sun-drying, grinding, sieving, homogenising, packaging, and gamma irradiation. The final produced CRM was packaged at 50 g per unit and stored at 20 degrees C. Certification was performed using isotope dilution-liquid chromatography-tandem mass spectrometry. CRM characterization was performed in eight laboratories in accordance with the requirements of ISO Guide 35. The certified values and expanded uncertainties (at a confidence of 95%, k = 2) for DON, NIV, DON-3G, and ZEN were determined to be 0.98 +/- 0.12 mg/kg, 1.37 +/- 0.20 mg/kg, 242 +/- 35 mu g/g, and 382 +/- 50 mu g/g. The CRM was sufficiently homogeneous between and within bottles, and remained stable for up to 12 months at 20 degrees C and 9 days below 40 degrees C for transportation. Thus, CRM can be used for quality control and method validation to ensure the accurate and reliable quantification of the main Fusarium mycotoxins in whole-wheat flour.
引用
收藏
页数:15
相关论文
共 47 条
  • [31] Study of the Stability and Homogeneity of Powdered Egg Matrix as a Candidate for Certified Reference Material for the Determination of Centesimal Composition
    Lopes, Tiago Antonio M.
    Chiavelli, Lucas Ulisses R.
    dos Santos, Patricia Daniele S.
    V. Visentainer, Jesui
    Santos, Oscar O.
    JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2024, 35 (06)
  • [32] A new marine sediment certified reference material (CRM) for the determination of persistent organic contaminants: IAEA-459
    Imma Tolosa
    Roberto Cassi
    David Huertas
    Environmental Science and Pollution Research, 2019, 26 : 7347 - 7355
  • [34] A new marine sediment certified reference material (CRM) for the determination of persistent organic contaminants: IAEA-459
    Tolosa, Imma
    Cassi, Roberto
    Huertas, David
    ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2019, 26 (08) : 7347 - 7355
  • [35] PRODUCTION OF CERTIFIED REFERENCE MATERIAL - THE ACCURATE DETERMINATION OF CARBON IN STEELS IN THE RANGE OF 11 TO 2,561 MU-G/G
    STAATS, G
    FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1984, 317 (07): : 761 - 764
  • [36] A pilot study on the feasibility of the preparation of a new certified reference material based on the Antarctic scallop Adamussium colbecki
    Caimi, S
    Senofonte, O
    Kramer, GN
    Robouch, P
    Caroli, S
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2004, 84 (6-7) : 551 - 557
  • [37] Value Assignment Study on a New Certified Reference Material of Cyclovirobuxine D by Differential Scanning Calorimetry Method
    Zhang, Li
    Lu, Yang
    Guo, Yonghui
    Xu, Wei
    Jin, Guimin
    Du, Guanhua
    CURRENT ANALYTICAL CHEMISTRY, 2016, 12 (06) : 568 - 572
  • [38] Determination of the Fusarium mycotoxins nivalenol, deoxynivalenol, 3-acetyldeoxynivalenol, and 15-O-acetyl-4-deoxynivalenol in contaminated whole wheat flour by liquid chromatography with diode array detection and gas chromatography with electron capture detection
    Walker, F
    Meier, B
    JOURNAL OF AOAC INTERNATIONAL, 1998, 81 (04) : 741 - 748
  • [39] Study of a new matrix certified reference material for simultaneous measurement of two plant growth regulators residues in tomato
    Chen, Wenwen
    Shi, Haochuan
    Yang, Yangzhongfu
    Yan, Jingjing
    Wang, Min
    Zhou, Jian
    Li, Liang
    Yang, Mengrui
    MICROCHEMICAL JOURNAL, 2024, 202
  • [40] Potential candidates of certified reference material for determination of hydrogen concentration with glow discharge optical emission spectrometry (GD-OES) -: a feasibility study
    Hodoroaba, Vasile-Dan
    Klemm, Denis
    Reinholz, Uwe
    Strub, Erik
    Roehrich, Joerg
    Bohne, Wolfgang
    Hoffmann, Volker
    Wetzig, Klaus
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2008, 23 (04) : 460 - 462