A novel fully-automated method to measure steroids in serum by liquid chromatography-tandem mass spectrometry

被引:8
|
作者
Fraissinet, Francois [1 ]
Pereira, Tony [1 ]
Violin, Alizee [2 ]
Feugray, Guillaume [1 ,3 ]
Bach-Ngohou, Kalyane [2 ,4 ]
Brunel, Valery [1 ]
机构
[1] Rouen Univ Hosp, Dept Gen Biochem, F-76000 Rouen, France
[2] Nantes Univ, Dept Biol, Lab Biochem, CHU Nantes, F-44000 Nantes, France
[3] Normandie Univ, UNIROUEN, INSERM U1096, Rouen, France
[4] Nantes Univ, CHU Nantes, INSERM, Enter Nervous Syst Gut & Brain Disorders,IMAD, F-44000 Nantes, France
关键词
Radioimmunoassay; Liquid chromatography tandem mass; spectrometry; Automation; Testosterone; Steroids; CANDIDATE REFERENCE METHOD; TOTAL TESTOSTERONE; ANDROSTENEDIONE; QUANTIFICATION; PROFILE; PLASMA; ASSAY;
D O I
10.1016/j.jmsacl.2022.12.004
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: Steroids play a key role in numerous physiological processes. Steroid determination is a useful tool to explore various endocrine diseases. Because of its specificity, mass spectrometry is considered to be a reference method for the determination of steroids in serum compared to radioimmunoassay. This technology could progress towards more automation for the optimal organization of clinical laboratories and ultimately for the benefit of patients.Methods: A fully automated ultra-high-performance liquid chromatography-tandem mass spectrometry method was developed and fully validated to determine five steroids in serum. Sample preparation was based on protein precipitation with filtration followed by online solid phase extraction. Chromatographic separation was performed using a biphenyl stationary phase.Results: The method was successfully validated according to European Medicine Agency guidelines. Coefficients of variation did not exceed, respectively, 8.4% and 8.1% for intra-and inter-assay precision. Method comparison with radioimmunoassay showed a proportional bias for all compounds, except for testosterone in men. Comparison with another LC-MS/MS method demonstrated acceptable concordance for all steroids, although a small bias was observed for androstenedione.Conclusion: The novelty of this method is that it has been fully automated. Automation provides benefits in traceability and allows significant savings in cost and time.
引用
收藏
页码:24 / 32
页数:9
相关论文
共 50 条
  • [21] Determination of anabolic steroids in bovine urine by liquid chromatography-tandem mass spectrometry
    Kaklamanos, George
    Theodoridis, Georgios
    Dabalis, Themistoklis
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2009, 877 (23): : 2330 - 2336
  • [22] Determination of anabolic steroids in muscle tissue by liquid chromatography-tandem mass spectrometry
    Kaklamanos, George
    Theodoridis, Georgios
    Dabalis, Themistoklis
    JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (46) : 8072 - 8079
  • [23] Determination of anabolic steroids in dietary supplements by liquid chromatography-tandem mass spectrometry
    Van Poucke, C.
    Detavernier, C.
    Van Cauwenberghe, R.
    Van Peteghem, C.
    ANALYTICA CHIMICA ACTA, 2007, 586 (1-2) : 35 - 42
  • [24] Confirmatory analysis of steroids in muscle using liquid chromatography-tandem mass spectrometry
    Pedersen, Mikael
    Andersen, Jens Hinge
    FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT, 2011, 28 (04): : 428 - 437
  • [25] An automated screening method for drugs and toxic compounds in human serum and urine using liquid chromatography-tandem mass spectrometry
    Sturm, Stefan
    Hammann, Felix
    Drewe, Juergen
    Maurer, Hans H.
    Scholer, Andre
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2010, 878 (28): : 2726 - 2732
  • [26] A fully automated on-line preconcentration and liquid chromatography-tandem mass spectrometry method for the analysis of anti-infectives in wastewaters
    Segura, Pedro A.
    Gagnon, Christian
    Sauve, Sebastien
    ANALYTICA CHIMICA ACTA, 2007, 604 (02) : 147 - 157
  • [27] Liquid chromatography-tandem mass spectrometry for the quantification of total testosterone in serum
    Shi, H.
    Carlow, D.
    CLINICAL CHEMISTRY, 2008, 54 (06) : A15 - A16
  • [28] Analysis of thyroid hormones in serum by liquid chromatography-tandem mass spectrometry
    Wang, Dongli
    Stapleton, Heather M.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2010, 397 (05) : 1831 - 1839
  • [29] Analysis of thyroid hormones in serum by liquid chromatography-tandem mass spectrometry
    Dongli Wang
    Heather M. Stapleton
    Analytical and Bioanalytical Chemistry, 2010, 397 : 1831 - 1839
  • [30] Determination of Lamotrigine in Human Serum By Liquid Chromatography-Tandem Mass Spectrometry
    Lee, W.
    Yoon, S.
    Park, Y.
    Suh, B.
    Kwon, O. H.
    CLINICAL CHEMISTRY, 2009, 55 (06) : A261 - A261