A novel fully-automated method to measure steroids in serum by liquid chromatography-tandem mass spectrometry

被引:8
|
作者
Fraissinet, Francois [1 ]
Pereira, Tony [1 ]
Violin, Alizee [2 ]
Feugray, Guillaume [1 ,3 ]
Bach-Ngohou, Kalyane [2 ,4 ]
Brunel, Valery [1 ]
机构
[1] Rouen Univ Hosp, Dept Gen Biochem, F-76000 Rouen, France
[2] Nantes Univ, Dept Biol, Lab Biochem, CHU Nantes, F-44000 Nantes, France
[3] Normandie Univ, UNIROUEN, INSERM U1096, Rouen, France
[4] Nantes Univ, CHU Nantes, INSERM, Enter Nervous Syst Gut & Brain Disorders,IMAD, F-44000 Nantes, France
关键词
Radioimmunoassay; Liquid chromatography tandem mass; spectrometry; Automation; Testosterone; Steroids; CANDIDATE REFERENCE METHOD; TOTAL TESTOSTERONE; ANDROSTENEDIONE; QUANTIFICATION; PROFILE; PLASMA; ASSAY;
D O I
10.1016/j.jmsacl.2022.12.004
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: Steroids play a key role in numerous physiological processes. Steroid determination is a useful tool to explore various endocrine diseases. Because of its specificity, mass spectrometry is considered to be a reference method for the determination of steroids in serum compared to radioimmunoassay. This technology could progress towards more automation for the optimal organization of clinical laboratories and ultimately for the benefit of patients.Methods: A fully automated ultra-high-performance liquid chromatography-tandem mass spectrometry method was developed and fully validated to determine five steroids in serum. Sample preparation was based on protein precipitation with filtration followed by online solid phase extraction. Chromatographic separation was performed using a biphenyl stationary phase.Results: The method was successfully validated according to European Medicine Agency guidelines. Coefficients of variation did not exceed, respectively, 8.4% and 8.1% for intra-and inter-assay precision. Method comparison with radioimmunoassay showed a proportional bias for all compounds, except for testosterone in men. Comparison with another LC-MS/MS method demonstrated acceptable concordance for all steroids, although a small bias was observed for androstenedione.Conclusion: The novelty of this method is that it has been fully automated. Automation provides benefits in traceability and allows significant savings in cost and time.
引用
收藏
页码:24 / 32
页数:9
相关论文
共 50 条
  • [1] A rapid and fully-automated method for the quantitation of tricyclic antidepressants in serum using turbulent-flow liquid chromatography-tandem mass spectrometry
    Breaud, Autumn R.
    Harlan, Robert
    Di Bussolo, Joseph M.
    McMillin, Gwendolyn A.
    Clarke, William
    CLINICA CHIMICA ACTA, 2010, 411 (11-12) : 825 - 832
  • [2] Determination of anabolic steroids in bovine serum by liquid chromatography-tandem mass spectrometry
    Kaklamanos, George
    Theodoridis, Georgios A.
    Dabalis, Themistoldis
    Papadoyannis, Ioannis
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2011, 879 (02): : 225 - 229
  • [4] Liquid chromatography-tandem mass spectrometry of some anabolic steroids
    Joos, PE
    Van Ryckeghem, M
    ANALYTICAL CHEMISTRY, 1999, 71 (20) : 4701 - 4710
  • [5] A rapid method to measure melatonin in biological fluids (milk and serum) with liquid chromatography-tandem mass spectrometry
    Yao, Songyang
    Liu, Xuening
    Fu, Yao
    Guan, Shengyu
    Liu, Yunjie
    Yan, Laiqing
    He, Pingli
    Liu, Guoshi
    FOOD CHEMISTRY, 2023, 404
  • [6] A fully automated turbulent-flow liquid chromatography-tandem mass spectrometry technique for monitoring antidepressants in human serum
    Sauvage, FL
    Gaulier, JM
    Lachâtre, G
    Marquet, P
    THERAPEUTIC DRUG MONITORING, 2006, 28 (01) : 123 - 130
  • [7] Determination of endogenous steroids in urine by liquid chromatography-tandem mass spectrometry
    Wang Mengye
    Xiang Ping
    Yan Hui
    Shen Baohua
    Shen Min
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2008, 26 (01) : 10 - 14
  • [8] Mucopolysaccharides quantitation in serum by liquid chromatography-tandem mass spectrometry
    Raymond, Kimiyo
    Lacey, Jean M.
    Dimitar, Gavrilov
    Matern, Dietrich
    Oglesbee, Devin
    Rinaldo, Piero
    Tortorelli, Silvia
    MOLECULAR GENETICS AND METABOLISM, 2018, 123 (02) : S123 - S123
  • [9] Determination of serum amantadine by liquid chromatography-tandem mass spectrometry
    Arndt, T
    Guessregen, B
    Hohl, A
    Reis, J
    CLINICA CHIMICA ACTA, 2005, 359 (1-2) : 125 - 131
  • [10] Determination of testosterone in serum by liquid chromatography-tandem mass spectrometry
    Turpeinen, U.
    Linko, S.
    Itkonen, O.
    Hamalainen, E.
    SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 2008, 68 (01): : 50 - 57