Multivariate Optimization and Validation of a Modified QuEChERS Method for Determination of PAHs and PCBs in Grilled Meat by GC-MS

被引:5
|
作者
Ostadgholami, Mahsa [1 ]
Zeeb, Mohsen [1 ]
Amirahmadi, Maryam [2 ,3 ]
Daraei, Bahram [4 ]
机构
[1] Islamic Azad Univ, Fac Sci, Dept Appl Chem, South Tehran Branch, Tehran 1777613651, Iran
[2] Minist Hlth & Med Educ, Iran Food & Drug Adm IFDA, Food & Drug Reference Control Lab FDRCL, Tehran 1113615911, Iran
[3] Minist Hlth & Med Educ, Iran Food & Drug Adm IFDA, Food & Drug Lab Res Ctr FDLRC, Tehran 1113615911, Iran
[4] Shahid Beheshti Univ Med Sci, Sch Pharm, Dept Toxicol & Pharmacol, Tehran 1996835113, Iran
关键词
central composite design; contaminants analysis; gas chromatography-mass spectrometry; grilled meat; PAHs; PCBs; POLYCYCLIC AROMATIC-HYDROCARBONS; PRESSURE GAS-CHROMATOGRAPHY; POLYCHLORINATED-BIPHENYLS; ENVIRONMENTAL CONTAMINANTS; MASS-SPECTROMETRY; EXTRACTION METHOD; PESTICIDES; FOOD; PRODUCTS; EXPOSURE;
D O I
10.3390/foods13010143
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
Polycyclic aromatic hydrocarbons (PAHs) and polychlorinated biphenyls (PCBs) are recognized as carcinogens and mutagenic food contaminants that threaten public health. As for food safety aspects, control of these contaminants in processed and fatty food is necessary. In this study, eleven factors were screened by the Plackett-Burman design, and four variables were chosen to optimize with the central composite design (CCD) for the improvement of extraction and cleanup procedures of these food contaminants. The optimized variables include 5 g of sample, 2 mL mixture of 2/2/1 ethyl acetate/acetone/isooctane, 1.6 g of ammonium formate, 0.9 g of sodium chloride, and 0.25 g of sorbent Z-Sep+. A 5 min cleanup vortex time with the spike calibration curve strategy, analyzed by gas chromatography-mass spectrometry (GC-MS), led to the validated limits of quantification (LOQs) for 16 PAHs and 36 PCBs of 0.5-2 and 0.5-1 ng/g, respectively, and recoveries of 72-120%, with an average relative standard deviation (%RSD) of 17, for PAHs, and 80-120%, with an %RSD of 3, for PCBs. The method introduces excellent accuracy, precision, and efficiency, and minimizes matrix effects, and ensures a control procedure, adopted with international standards, for food authorities to determine the contaminants of interest in processed meat, and consequently, prevent food-borne disease to improve public health indices.
引用
收藏
页数:20
相关论文
共 50 条
  • [31] Optimization of a Multi-Residue Analytical Method during Determination of Pesticides in Meat Products by GC-MS/MS
    Lee, Sang-Hyeob
    Kwak, Se-Yeon
    Sarker, Aniruddha
    Moon, Joon-Kwan
    Kim, Jang-Eok
    FOODS, 2022, 11 (19)
  • [32] High-throughput determination of valproate in human samples by modified QuEChERS extraction and GC-MS/MS
    Mizuno, Shun
    Lee, Xiao-Pen
    Fujishiro, Masaya
    Matsuyama, Takaaki
    Yamada, Miho
    Sakamoto, Yuki
    Kusano, Maiko
    Zaitsu, Kei
    Hasegawa, Chika
    Hasegawa, Iwao
    Kumazawa, Takeshi
    Ishii, Akira
    Sato, Keizo
    LEGAL MEDICINE, 2018, 31 : 66 - 73
  • [33] Validation of GC-MS method for determination of varroacide residues in propolis
    Cvek, J.
    Fingler, S.
    Tomic, S.
    Medic-Saric, M.
    PLANTA MEDICA, 2009, 75 (09) : 991 - 992
  • [34] Determination of 2 Phthalic Acid Esters in Fermented Grains by GC-MS/MS Coupled with Modified QuEChERS
    Jiang, Lili
    Shang, Yuhao
    Li, Fuxiao
    Tian, Dongwei
    Zhu, Xiajian
    Hu, Feng
    Cheng, Pingyan
    Hu, Jianfeng
    FOOD ANALYTICAL METHODS, 2024, 17 (04) : 574 - 584
  • [35] Determination of 16 phthalate esters in tea samples using a modified QuEChERS sample preparation method combined with GC-MS/MS
    Yin, Peng
    Liu, Xin
    Chen, Hongping
    Pan, Rong
    Ma, Guicen
    FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT, 2014, 31 (08): : 1406 - 1413
  • [36] Validation of a modified QuEChERS extraction/GC-MS methodology for quantification of drugs of abuse in human samples
    Alves, E.
    Agonia Ferreira, A. S.
    Afonso, C. M.
    Cravo, S. M.
    Duarte Pereira Netto, A.
    Carvalho, F.
    Dinis-Oliveira, R. J.
    TOXICOLOGY LETTERS, 2015, 238 (02) : S376 - S376
  • [37] OPTIMIZATION AND VALIDATION OF A METHOD USING MODIFIED QuEChERS AND LC-ESI-MS/MS FOR THE DETERMINATION OF PESTICIDES IN ONION
    Rodrigues, Sherol Acosta
    Caldas, Sergiane Souza
    Furlong, Eliana Badiale
    Primel, Ednei Gilberto
    Zanella, Renato
    QUIMICA NOVA, 2011, 34 (05): : 780 - U62
  • [38] Determination of hydroxy derivatives of PAHs in sewage sludge by GC-MS/ MS
    Frydel, Laura
    Prus, Zuzanna
    Cwynar, Karolina
    Pamula, Justyna
    Pyssa, Justyna
    Rego, Rosa
    Styszko, Katarzyna
    DESALINATION AND WATER TREATMENT, 2025, 321
  • [39] Application of the QuEChERS method for the determination of pesticides, PAHs and PCBs in fish in Senegal
    Dione, Cheikh Tidiane
    Delhomme, Olivier
    Diagne, Ibrahima
    Diebakate, Cheikhna
    Ndiaye, Birame
    Cisse, Dame
    Hane, Maoudo
    Dione, Mame Mor
    Diouf, Sitor
    Diop, Abdoulaye
    Ndiaye, Momar
    Millet, Maurice
    JOURNAL OF ENVIRONMENTAL SCIENCE AND HEALTH PART A-TOXIC/HAZARDOUS SUBSTANCES & ENVIRONMENTAL ENGINEERING, 2022, 57 (10): : 869 - 879
  • [40] Determination of Organochlorine Pesticides in Serum via QuEChERS and GC-MS
    Wang, Xiaoyan
    LC GC NORTH AMERICA, 2015, : 9 - 9