Updating approach for lexicographic optimization-based planning to improve cervical cancer plan quality

被引:1
|
作者
Caricato, Paolo [1 ,2 ]
Trivellato, Sara [1 ]
Pellegrini, Roberto [3 ]
Montanari, Gianluca [1 ]
Daniotti, Martina Camilla [1 ,2 ]
Bordigoni, Bianca [1 ,4 ]
Faccenda, Valeria [1 ,2 ]
Panizza, Denis [1 ,5 ]
Meregalli, Sofia [5 ,6 ]
Bonetto, Elisa [6 ]
Voet, Peter [7 ]
Arcangeli, Stefano [5 ,6 ]
De Ponti, Elena [1 ,5 ]
机构
[1] Fdn IRCCS San Gerardo Tintori, Med Phys Dept, Monza, Italy
[2] Univ Milan, Dept Phys, Milan, Italy
[3] Elekta AB, Med Affairs, Stockholm, Sweden
[4] Univ Milano Bicocca, Dept Phys, Milan, Italy
[5] Univ Milano Bicocca, Sch Med & Surg, Milan, Italy
[6] Fdn IRCCS San Gerardo Tintori, Dept Radiat Oncol, Monza, Italy
[7] Elekta AB, Res Clin Liaison, Stockholm, Sweden
关键词
Lexicographic optimization; Automated planning; Cervical cancer; VMAT; Plan quality; Plan comparison; MODULATED ARC THERAPY; PRECLINICAL VALIDATION; VMAT; GENERATION;
D O I
10.1007/s12672-023-00800-5
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
BackgroundTo investigate the capability of a not-yet commercially available fully automated lexicographic optimization (LO) planning algorithm, called mCycle (Elekta AB, Stockholm, Sweden), to further improve the plan quality of an already-validated Wish List (WL) pushing on the organs-at-risk (OAR) sparing without compromising target coverage and plan delivery accuracy.Material and MethodsTwenty-four mono-institutional consecutive cervical cancer Volumetric-Modulated Arc Therapy (VMAT) plans delivered between November 2019 and April 2022 (50 Gy/25 fractions) have been retrospectively selected. In mCycle the LO planning algorithm was combined with the a-priori multi-criterial optimization (MCO). Two versions of WL have been defined to reproduce manual plans (WL01), and to improve the OAR sparing without affecting minimum target coverage and plan delivery accuracy (WL02). Robust WLs have been tuned using a subset of 4 randomly selected patients. The remaining plans have been automatically re-planned by using the designed WLs. Manual plans (MP) and mCycle plans (mCP01 and mCP02) were compared in terms of dose distributions, complexity, delivery accuracy, and clinical acceptability. Two senior physicians independently performed a blind clinical evaluation, ranking the three competing plans. Furthermore, a previous defined global quality index has been used to gather into a single score the plan quality evaluation.ResultsThe WL tweaking requests 5 and 3 working days for the WL01 and the WL02, respectively. The re-planning took in both cases 3 working days. mCP01 best performed in terms of target coverage (PTV V95% (%): MP 98.0 [95.6-99.3], mCP01 99.2 [89.7-99.9], mCP02 96.9 [89.4-99.5]), while mCP02 showed a large OAR sparing improvement, especially in the rectum parameters (e.g., Rectum D50% (Gy): MP 41.7 [30.2-47.0], mCP01 40.3 [31.4-45.8], mCP02 32.6 [26.9-42.6]). An increase in plan complexity has been registered in mCPs without affecting plan delivery accuracy. In the blind comparisons, all automated plans were considered clinically acceptable, and mCPs were preferred over MP in 90% of cases. Globally, automated plans registered a plan quality score at least comparable to MP.ConclusionsThis study showed the flexibility of the Lexicographic approach in creating more demanding Wish Lists able to potentially minimize toxicities in RT plans.
引用
收藏
页数:17
相关论文
共 50 条
  • [41] Structural damage identification using optimization-based FE model updating
    Lamperova, K.
    Lehky, D.
    Slowik, O.
    CURRENT PERSPECTIVES AND NEW DIRECTIONS IN MECHANICS, MODELLING AND DESIGN OF STRUCTURAL SYSTEMS, 2022, : 643 - 644
  • [42] Path planning with limited numbers of maneuvers for automatic guided vehicles: An optimization-based approach
    Micelli, Piero
    Consolini, Luca
    Locatelli, Marco
    2017 25th Mediterranean Conference on Control and Automation, MED 2017, 2017, : 204 - 209
  • [43] Plan quality and treatment efficiency assurance of two VMAT optimization for cervical cancer radiotherapy
    Huang, Sijuan
    Mai, Xiuying
    Liu, Hongdong
    Sun, Wenzhao
    Zhu, Jinhan
    Du, Jinlong
    Lin, Xi
    Du, Yujie
    Zhang, Kang
    Yang, Xin
    Huang, Xiaoyan
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2023, 24 (10):
  • [44] Generative Modeling of Pedestrian Behavior: A Receding Horizon Optimization-Based Trajectory Planning Approach
    Gupta, Saumya
    Zaki, Mohamed H.
    Vela, Adan
    IEEE ACCESS, 2022, 10 : 81624 - 81641
  • [45] Multi-center dosimetric predictions to improve plan quality for brachytherapy for cervical cancer treatment
    Reijtenbagh, Dominique M. W.
    Godart, Jeremy
    de Leeuw, Astrid A. C.
    Jurgenliemk-Schulz, Ina M.
    Mens, Jan-Willem M.
    Huge, Michele
    Hoogeman, Mischa S.
    RADIOTHERAPY AND ONCOLOGY, 2023, 182
  • [46] Automated planning through explicit optimization of plan quality
    Engberg, L.
    Eriksson, K.
    Forsgren, A.
    RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S1025 - S1026
  • [47] An Optimization-Based Receding Horizon Trajectory Planning Algorithm
    Bergman, Kristoffer
    Ljungqvist, Oskar
    Glad, Torkel
    Axehill, Daniel
    IFAC PAPERSONLINE, 2020, 53 (02): : 15550 - 15557
  • [48] Environment Modeling for the Application in Optimization-based Trajectory Planning
    Lienke, Christian
    Keller, Martin
    Glander, Karl-Heinz
    Bertram, Torsten
    2018 IEEE INTELLIGENT VEHICLES SYMPOSIUM (IV), 2018, : 498 - 503
  • [49] Optimization-based analysis of collaborative airport arrival planning
    Andersson, K
    Hall, W
    Atkins, S
    Feron, E
    TRANSPORTATION SCIENCE, 2003, 37 (04) : 422 - 433
  • [50] Optimization-Based Hierarchical Motion Planning for Autonomous Racing
    Vazquez, Jose L.
    Bruehlmeier, Marius
    Liniger, Alexander
    Rupenyan, Alisa
    Lygeros, John
    2020 IEEE/RSJ INTERNATIONAL CONFERENCE ON INTELLIGENT ROBOTS AND SYSTEMS (IROS), 2020, : 2397 - 2403