A Novel Method for Developing Thin Resin Scintillator Screens and Application in an X-ray CMOS Imaging Sensor

被引:0
|
作者
Linardatos, Dionysios [1 ]
Fountos, George [1 ]
Valais, Ioannis [1 ]
Michail, Christos [1 ]
机构
[1] Univ West Attica, Dept Biomed Engn, Radiat Phys Mat Technol & Biomed Imaging Lab, Athens 12210, Greece
关键词
CMOS sensors; X-ray; Gd2O2S; Tb; non-destructive testing; DQE; scintillators; epoxy resin; sedimentation; graphite; 3D printing; PERFORMANCE; NOISE; PHOSPHORS; QUANTUM;
D O I
10.3390/s23146588
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Scintillating screens for X-ray imaging applications are prepared with various methods. Among them, the classic sedimentation method presents certain weak points. In this context, a novel fabrication process was developed that offers simplicity, economy of resources and time, while the screens exhibit adequate durability and image quality performance. The proposed technique involves a resin mixture that contains the phosphor in powder form (Gd2O2S:Tb in the present work) and graphite. The novel method was optimized and validated by coupling the screens to a complementary metal oxide semiconductor (CMOS) X-ray sensor. Indicatively, screens of two surface densities were examined; 34 mg/cm(2) and 70 mg/cm(2). Various established image quality metrics were calculated following the IEC 62220-1 international standard, including the detective quantum efficiency (DQE). Comparisons were carried out under the same conditions, with a sedimentation screen reported previously and a screen of wide commercial circulation (Carestream Min-R 2190). The novel screens exhibit has comparable or even better performance in image-quality metrics. The 34 mg/cm(2) screen achieves a DQE 15-20% greater than its comparison counterpart, and its limiting resolution was 5.3 cycles/mm. The detector coupled to the 70 mg/cm(2) screen achieved a DQE 10-24% greater than its own counterpart, and its limiting resolution was found to be 5.4 cycles/mm.
引用
收藏
页数:18
相关论文
共 50 条
  • [31] Cascade modeling of pixelated scintillator detectors for x-ray imaging
    Kim, Ho Kyung
    Yun, Seung Man
    Ko, Jong Soo
    Cho, Gyuseong
    Graeve, Thorsten
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2008, 55 (03) : 1357 - 1366
  • [32] A new large area scintillator screen for X-ray imaging
    Nagarkar, VV
    Miller, SR
    Tipnis, SV
    Lempicki, A
    Brecher, C
    Lingertat, H
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2004, 213 : 250 - 254
  • [33] Bright Semiconductor Scintillator for High Resolution X-Ray Imaging
    Nagarkar, Vivek V.
    Gaysinskiy, Valeriy
    Ovechkina, Olena
    Miller, Stuart
    Singh, Bipin
    Guo, Liang
    Irving, Thomas
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 2387 - +
  • [34] Performance of an X-ray imaging detector based on a structured scintillator
    Svenonius, Olof
    Sahlholm, Anna
    Wiklund, Per
    Linnros, Jan
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 607 (01): : 138 - 140
  • [35] An X-ray imaging detector based on pixel structured scintillator
    Kim, Byoung-Jik
    Cho, Gyuseong
    Cha, Bo Kyung
    Kang, Bosun
    RADIATION MEASUREMENTS, 2007, 42 (08) : 1415 - 1418
  • [36] Bright Semiconductor Scintillator for High Resolution X-Ray Imaging
    Nagarkar, Vivek V.
    Gaysinskiy, Valeriy
    Ovechkina, Olena E.
    Miller, Stuart
    Singh, Bipin
    Guo, Liang
    Irving, Thomas
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2010, 57 (03) : 923 - 930
  • [37] Rubidium copper chloride scintillator for X-ray imaging screen
    Naewthong, Worakit
    Juntapo, Waridsaraporn
    Amarit, Ratthasart
    Duangkanya, Kamonchanok
    Sumriddetchkajorn, Sarun
    Rungseesumran, Thiti
    Kamwang, Natthaporn
    Tariwong, Yaowaluk
    Kaewkhao, Jakrapong
    Kopwitthaya, Atcha
    OPTICAL MATERIALS EXPRESS, 2022, 12 (01): : 308 - 316
  • [38] Direct Deposition of Microcolumnar Scintillator on CMOS SSPM Array: Toward a Photon Counting Detector for X-Ray/Gamma Ray Imaging
    Prekas, G.
    Breen, M.
    Sabet, H.
    Bhandari, H.
    Derderian, G.
    Robertson, F., Jr.
    Stapels, C. J.
    Christian, J.
    Cool, S.
    Nagarkar, V. V.
    APPLICATIONS OF NUCLEAR TECHNIQUES: ELEVENTH INTERNATIONAL CONFERENCE, 2011, 1412
  • [39] Fast frame rate rodent cardiac X-ray imaging using scintillator lens coupled to CMOS camera
    Lakshmi, Swathi B.
    Varsha, M. K. N. Sai
    Kumar, Ashwin N.
    Dixit, Madhulika
    Krishnamurthi, Ganapathy
    MEDICAL IMAGING 2017: PHYSICS OF MEDICAL IMAGING, 2017, 10132
  • [40] Investigation of the Performance of Scintillator-Based CMOS Flat Panel Detectors for X-Ray and Thermal Neutron Imaging
    Cha, Bo Kyung
    Kim, Jong Yul
    Kim, Tae Joo
    Kim, Yikyung
    Sim, Cheulmuu
    Lee, Seung Wook
    Cho, Gyuseong
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2010, 57 (03) : 1409 - 1413