Fault-tolerant control strategy of six-phase permanent magnet synchronous motor based on deadbeat current prediction

被引:1
|
作者
Gao, Hanying [1 ]
Chen, Qi [1 ]
Liang, Shenghan [1 ]
Dong, Yao [1 ]
机构
[1] Harbin Univ Sci & Technol, Sch Elect & Elect Engn, Harbin, Peoples R China
来源
PLOS ONE | 2023年 / 18卷 / 07期
基金
中国国家自然科学基金;
关键词
TORQUE CONTROL; OPERATION;
D O I
10.1371/journal.pone.0288728
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
The fault-tolerant control after phase loss is crucial in the studies of the six-phase permanent magnet synchronous motor (PMSM), and the one phase loss is the most frequent phase loss fault. To improve the system instability caused by nonlinear and time-varying perturbations of inductance parameters in a double-Y phase shifted 30 & DEG; six-phase PMSM, an improved deadbeat predictive current fault-tolerant control (DPC-FTC) method is proposed in this study. The transformation matrix after single-phase open-phase is first reduced and reconstructed, and the reduced-dimensional voltage equation is derived. Based on this equation, the deadbeat current predictive control is then used to predict the expected voltage using the current feedback value and the reference value, so as to shorten the response time and improve the overall control effect. The voltage equation after parameter perturbation is rewritten, and the current discrete transfer function under constant expected voltage before and after parameter perturbation is calculated. Afterwards, to further improve the low stability of fault-tolerant control after phase loss, which is caused by the inductance parameter perturbation of the control system, the weight coefficient is introduced in order to enhance the deadbeat predictive current control so that it splits and optimizes the direct-quadrature axis current. The stability of the system is then analyzed. By changing the weight coefficient, the fault-tolerant control system has a wider stable working range. Finally, the simulation model and experimental platform are completed. The results show that the improved DPC-FTC method improves the permissible inductor parameter uptake range by a factor of 1/& beta;, reduces the current static difference by 32.05% and 46.02% when the inductor parameter is mismatched by a factor of 2, reduces the current oscillation and effectively reduces the sensitivity of system stability to inductor parameter uptake.
引用
收藏
页数:29
相关论文
共 50 条
  • [41] Fault-Tolerant Control of Five-Phase Permanent Magnet Synchronous Hub Motor Based on Improved Model Predictive Current Control
    Li, Teng
    Yao, Ming
    Sun, Xiaodong
    JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY, 2023, 19 (01) : 247 - 257
  • [42] Fault-Tolerant Control of Five-Phase Permanent Magnet Synchronous Hub Motor Based on Improved Model Predictive Current Control
    Teng Li
    Ming Yao
    Xiaodong Sun
    Journal of Electrical Engineering & Technology, 2024, 19 : 247 - 257
  • [43] Sensorless Fault-Tolerant Control of Dual Three-Phase Permanent Magnet Synchronous Motor
    Cao, Fan
    Lu, Haifeng
    Meng, Yonggang
    Gao, Dawei
    WORLD ELECTRIC VEHICLE JOURNAL, 2021, 12 (04):
  • [44] Fault-Tolerant Control of a Five-Phase Permanent Magnet Synchronous Motor for Industry Applications
    Tian, Bing
    Mirzaeva, Galina
    An, Qun-Tao
    Sun, Li
    Semenov, Dmitry
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2018, 54 (04) : 3943 - 3952
  • [45] Investigation on Slot and Pole Combination Schemes for Six-phase Fault-Tolerant Permanent Magnet Rim Driven Motor
    Ma, Rui
    Zhu, Jingwei
    Lin, Qianhong
    Xu, Xiaohui
    2018 1ST IEEE STUDENT CONFERENCE ON ELECTRIC MACHINES AND SYSTEMS (IEEE SCEMS), 2018,
  • [46] Fault-tolerant Control for Dual Permanent Magnet Synchronous Motor Drive Based on Improved Current Hysteresis Algorithm
    Lin, Hai
    Xia, Dengkai
    Li, Feng
    Zhou, Xiwei
    Li, Jie
    Zhao, Fei
    2019 22ND INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS (ICEMS 2019), 2019, : 5145 - 5148
  • [47] Six-phase ten-pole fault tolerant permanent magnet machine and its control strategy
    Hao, Zhengyang
    Hu, Yuwen
    Huang, Wenxin
    Yu, Wentao
    Xu, Shun
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2010, 30 (30): : 81 - 86
  • [48] Research on Open-circuit Fault Tolerant Control of Six-phase Permanent Magnet Synchronous Machine Based on Fifth Harmonic Current Injection
    Zhifeng Zhang
    Yue Wu
    Hequn Su
    Quanzeng Sun
    CES Transactions on Electrical Machines and Systems, 2022, 6 (03) : 306 - 314
  • [49] Control Strategy for a Four-Phase Fault-Tolerant Permanent-Magnet Synchronous Machine
    Zhou, Haisong
    Yu, Bin
    Lin, Zhanxi
    Wang, Haipeng
    Li, Xiaopeng
    Zheng, Ping
    2014 17TH INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS (ICEMS), 2014, : 1213 - 1218
  • [50] Research on Open-circuit Fault Tolerant Control of Six-phase Permanent Magnet Synchronous Machine Based on Fifth Harmonic Current Injection
    Zhang, Zhifeng
    Wu, Yue
    Su, Hequn
    Sun, Quanzeng
    CES TRANSACTIONS ON ELECTRICAL MACHINES AND SYSTEMS, 2022, 6 (03) : 306 - 314