Value of micro-flow imaging and high-definition micro-flow imaging in differentiating malignant and benign breast lesions

被引:1
|
作者
Luo, R. [1 ,2 ]
Zhang, Y. [2 ]
Jiang, W. [2 ]
Wang, Y. [2 ]
Luo, Y. [2 ]
机构
[1] Yangzhou Univ, Med Coll, Yangzhou, Jiangsu, Peoples R China
[2] Chinese Peoples Liberat Army Gen Hosp, Div Med Ctr 1, Dept Ultrasound, 28 Fuxing Rd, Beijing 100853, Peoples R China
关键词
DOPPLER; CANCER; VASCULARITY; PARAMETERS; MASSES;
D O I
10.1016/j.crad.2023.10.007
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
AIM: To evaluate the value of non-contrast micro-flow imaging (MFI) and high-definition micro-flow imaging (HD-MFI) in differentiating malignant and benign breast lesions.MATERIALS AND METHODS: One hundred and thirty-three patients with 138 breast lesions (80 benign and 58 malignant lesions) were examined using colour Doppler flow imaging (CDFI), MFI, and HD-MFI before biopsy, with blood flow signals graded into four types (grade 0, 1, 2, and 3) and penetrating vessels evaluated. The micro-vascular patterns of MFI and HD-MFI were evaluated and classified into five patterns: avascular, line-like, tree-like, root hair-like, and crab claw-like pattern. The diagnostic efficiency of micro-vascular patterns was ana-lysed. Moreover, ultrasound Breast Imaging Reporting and Data System (BI-RADS) 4A lesions were also re-assessed according to the micro-vascular patterns of MFI or HD-MFI. RESULTS: The capability of detecting blood flow and penetrating vessels from high to low was HD-MFI, MFI, and CDFI, respectively (p<0.05). Rich blood flow signals, penetrating vessels, and root hair-like or crab claw-like pattern were more likely in malignant breast lesions, while few blood flow signals, tree-like pattern were mostly in benign lesions (p<0.05). The diag-nostic efficiency of HD-MFI and MFI were higher than CDFI (p>0.05). MFI could reduce un-necessary biopsy of 52 US BI-RADS 4A lesions but with two malignancies missed, while 56 ultrasound BI-RADS 4A lesions could be downgraded by HD-MFI with none malignancies missed.CONCLUSIONS: MFI and HD-MFI can detect more blood flow in breast lesions than CDFI, and could help distinguish benign and malignant breast lesions. HD-MFI could reduce the un-necessary biopsy of US BI-RADS 4A lesions without missed malignancy.(c) 2023 Published by Elsevier Ltd on behalf of The Royal College of Radiologists.
引用
收藏
页码:e48 / e56
页数:9
相关论文
共 50 条
  • [21] Hydrodynamic focusing investigation in a micro-flow cytometer
    Yang, An-Shik
    Hsieh, Wen-Hsin
    BIOMEDICAL MICRODEVICES, 2007, 9 (02) : 113 - 122
  • [22] Micro-Flow Imaging: Flow Microscopy Applied to Sub-visible Particulate Analysis in Protein Formulations
    Sharma, Deepak K.
    King, Dave
    Oma, Peter
    Merchant, Clark
    AAPS JOURNAL, 2010, 12 (03): : 455 - 464
  • [23] Capillary Micro-Flow Through a Fiber Bundle(Ⅰ)
    祝颖丹
    Journal of Wuhan University of Technology-Materials Science, 2004, (02) : 94 - 97
  • [24] High performance micro-flow cytometer based on optical fibres
    S. Etcheverry
    A. Faridi
    H. Ramachandraiah
    T. Kumar
    W. Margulis
    F. Laurell
    A. Russom
    Scientific Reports, 7
  • [25] Micro-flow reaction systems for combinatorial syntheses
    Kikutani, Y
    Kitamori, T
    MACROMOLECULAR RAPID COMMUNICATIONS, 2004, 25 (01) : 158 - 168
  • [26] Heart-Like Micro-Flow Mixer
    Wang, Chin-Tsan
    Chen, Yan-Ming
    Chen, Shih-Syun
    INTERNATIONAL JOURNAL OF CHEMICAL REACTOR ENGINEERING, 2016, 14 (01) : 343 - 349
  • [27] Convection and diffusion in a micro-flow injection system
    van Akker, EB
    Bos, M
    van der Linden, WE
    ANALYTICA CHIMICA ACTA, 1998, 373 (2-3) : 227 - 239
  • [28] Development of a gas micro-flow transfer standard
    Barbe, J.
    Boineau, F.
    Mace, T.
    Otal, P.
    FLOW MEASUREMENT AND INSTRUMENTATION, 2015, 44 : 43 - 50
  • [29] Flowing thermal lens micro-flow velocimeter
    Kikutani, Yoshikuni
    Mawatari, Kazuma
    Katayama, Kenji
    Tokeshi, Manabu
    Fukuzawa, Takashi
    Kitaok, Mitsuo
    Kitamori, Takehiko
    SENSORS AND ACTUATORS B-CHEMICAL, 2008, 133 (01) : 91 - 96
  • [30] XM-flow: An extensible micro-flow for multimodal interaction
    Li, Li
    Chou, Wu
    Liu, Feng
    Cao, Fei
    2006 IEEE WORKSHOP ON MULTIMEDIA SIGNAL PROCESSING, 2006, : 497 - +