Structural behavior of axially loaded high strength concrete columns reinforced longitudinally with glass fibre reinforced polymer bars

被引:5
|
作者
Sasikumar, P. [1 ]
Manju, R. [1 ]
机构
[1] Anna Univ, Kumaraguru Coll Technol, Coimbatore, India
来源
REVISTA DE LA CONSTRUCCION | 2023年 / 22卷 / 02期
关键词
GFRP bar; stiffness; ductility; finite element model; high strength concrete; axial load; displacement; GFRP BARS; COMPRESSIVE BEHAVIOR;
D O I
10.7764/RDLC.22.2.293
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This study investigated the behaviour of axially loaded high strength concrete columns reinforced longitudinally with glass fibre reinforced polymer bars. Total six Reinforced Concrete (RC) columns and six Glass Fibre Reinforced Polymer (GFRP) reinforced concrete columns made with High Strength Concrete (HSC) with the addition of 1.20% of Alkali Resistant Glass Fibre (ARGF). The columns were cast with 1000 mm height and cross-sectional area is 150 mm x 150 mm and were tested under axial loading. The main objective of this study including to increase axial load carrying capacity and stiffness and reduce the ductility, mode of failure, and axial load-displacement response of columns. The RC columns are compared to the GFRP RC columns, and the GFRP RC columns are only carried 90% of the axial load compared to the RC columns. The Finite Element Model (FEM) was used to analyses all columns, and FEM helps predict the axial load.
引用
收藏
页码:293 / 305
页数:13
相关论文
共 50 条
  • [31] Strength and Deformation of Axially Loaded Fiber-Reinforced Polymer Sheet Confined Concrete Columns
    李静
    钱稼茹
    蒋剑彪
    TsinghuaScienceandTechnology, 2004, (02) : 130 - 137
  • [32] Performance evaluation of high strength concrete and steel fibre high strength concrete columns reinforced with GFRP bars and helices
    Hasan, Hayder Alaa
    Sheikh, M. Neaz
    Hadi, Muhammad N. S.
    CONSTRUCTION AND BUILDING MATERIALS, 2017, 134 : 297 - 310
  • [33] Strength Model for Concrete Columns Reinforced with Fiber-Reinforced Polymer Bars and Ties
    Tobbi, Hany
    Farghaly, Ahmed Sabry
    Benmokrane, Brahim
    ACI STRUCTURAL JOURNAL, 2014, 111 (04) : 789 - 798
  • [34] Behaviour of fibre reinforced high strength concrete columns
    Foster, SJ
    Attard, MM
    MECHANICS OF STRUCTURES AND MATERIALS, 1999, : 201 - 206
  • [36] Mechanical behavior of electronic waste concrete columns reinforced with structural fibers and glass fiber reinforced polymer bars: Experimental and analytical investigation
    Khan, Qaiser Uz Zaman
    El Ouni, Mohamed Hechmi
    Raza, Ali
    Alomayri, Thamer
    ADVANCES IN STRUCTURAL ENGINEERING, 2022, 25 (02) : 374 - 391
  • [37] Strength of biaxially loaded high strength reinforced concrete columns
    Dundar, Cengiz
    Tokgoz, Serkan
    STRUCTURAL ENGINEERING AND MECHANICS, 2012, 44 (05) : 649 - 661
  • [38] Experimental study of the seismic behavior of obliquely loaded concrete columns reinforced with high-strength steel bars
    Liu, Chunyang
    Yu, Guixin
    Li, Fei
    Guo, Changqun
    Fan, Xisen
    STRUCTURAL CONCRETE, 2021, 22 (03) : 1396 - 1409
  • [39] Evaluation of the flexural strength and serviceability of geopolymer concrete beams reinforced with glass-fibre-reinforced polymer (GFRP) bars
    Maranan, G. B.
    Manalo, A. C.
    Benmokrane, B.
    Karunasena, W.
    Mendis, P.
    ENGINEERING STRUCTURES, 2015, 101 : 529 - 541
  • [40] Inelastic design of low-axially loaded high-strength reinforced concrete columns
    Ho, JCM
    Pam, HJ
    ENGINEERING STRUCTURES, 2003, 25 (08) : 1083 - 1096