Design and Implementation of a Ku-Band High-Precision Blackbody Calibration Target

被引:2
|
作者
Liu, Jie [1 ]
Sun, Zhenlin [1 ]
Sun, Guangmin [1 ]
Li, Yu [1 ]
Cao, Tong [1 ]
Tang, Wenjie [1 ]
机构
[1] Beijing Univ Technol, Fac Informat Technol, Beijing 100124, Peoples R China
基金
中国国家自然科学基金;
关键词
blackbody calibration target; high emissivity; high temperature uniformity; finite element method; EMISSIVITY; SCATTERING; ARRAY;
D O I
10.3390/mi14010018
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Microwave radiometers can be used in human tissue temperature measurement scenarios due to the advantages of non-destructive and non-contact temperature measurement. However, their accuracy often cannot meet the needs of practical applications. In this paper, a Ku-Band high-precision blackbody calibration target is designed to provide calibration for microwave radiometers and meet the requirements of a high temperature-measurement accuracy and high temperature-measurement resolution. From a practical application point of view, the blackbody calibration target needs to have the characteristics of high emissivity and high temperature uniformity. However, previous studies on blackbody calibration targets often focused on the scattering characteristics or temperature uniformity of the calibration target separately, and thus lack a comprehensive consideration of the two characteristics. In this paper, the electromagnetic scattering model and the temperature-distribution model of the calibration target are established through the multi-physical simulation combined with the Finite Element Method. Then, according to the simulation results of the two characteristic models, the structural parameters and composition of the coated cone array are continuously optimized. In addition, to achieve high-precision temperature control of the blackbody calibration target, this paper studies three PID controller parameter self-tuning algorithms, namely, BP-PID, PSO-PID and Fuzzy-PID for the optimal parameter tuning problem of traditional PID algorithms and determines the optimal temperature-control algorithm by comparing the performance of heating and cooling processes. Then, the blackbody calibration target is processed and manufactured. The arch test system is used to validate the reflectance of the calibration target, the emissivity is calculated indirectly, and the temperature-distribution uniformity of the temperature-control panel of the calibration target is tested by a multi-point distribution method. Finally, the uncertainty of the brightness temperature of the blackbody calibration target is analyzed.
引用
收藏
页数:19
相关论文
共 50 条
  • [41] High-precision camera calibration based on a 1D target
    Duan, Yi
    Yu, Youlong
    Li, Peng
    Jiang, Shengyuan
    OPTICS EXPRESS, 2022, 30 (20) : 36873 - 36888
  • [42] Design of Ku-band MIMO Array Satellite Antenna
    Huang, Chung-Hao
    Xu, Chao-Chin
    Hsu, Chang-Chen
    2024 IEEE INTERNATIONAL WORKSHOP ON ELECTROMAGNETICS: APPLICATIONS AND STUDENT INNOVATION COMPETITION, IWEM 2024, 2024,
  • [43] Ground Calibration System Design of High-precision Star Sensor
    Duan, Jie
    An, Zhiyong
    Sun, Xiangyang
    MANUFACTURING PROCESS AND EQUIPMENT, PTS 1-4, 2013, 694-697 : 1068 - +
  • [44] Research of optimizing the microwave wide band blackbody calibration target
    Nian Feng
    Yang Yujie
    Wang Wei
    JOURNAL OF SYSTEMS ENGINEERING AND ELECTRONICS, 2009, 20 (01) : 6 - 12
  • [45] System Characterization and Polarimetric Calibration of the Ku-Band Advanced Polarimetric Interferometer
    Baffelli, Simone
    Frey, Othmar
    Werner, Charles
    Hajnsek, Irena
    11TH EUROPEAN CONFERENCE ON SYNTHETIC APERTURE RADAR (EUSAR 2016), 2016, : 735 - 740
  • [46] Design of a Compact Dual Band Microstrip Antenna for Ku-Band Application
    Misran, Norbahiah
    Islam, Mohammad Tariqul
    Yusob, Nurmahirah Muhamad
    Mobashsher, Ahmed Toaha
    2009 INTERNATIONAL CONFERENCE ON ELECTRICAL ENGINEERING AND INFORMATICS, VOLS 1 AND 2, 2009, : 670 - 673
  • [47] Research of optimizing the microwave wide band blackbody calibration target
    Nian Feng1
    2. Beijing Inst. of Radio Metrology & Measurement
    Journal of Systems Engineering and Electronics, 2009, 20 (01) : 6 - 12
  • [48] Design and implementation of high-precision voltage measurement system based on Kalman filter and automatic calibration technology
    Hu, Hongjun
    Shen, Haikuo
    Pu, Qian
    MEASUREMENT, 2022, 204
  • [49] A High efficiency Ku-band Printed Monopulse Array
    Jahagirdar, D. R.
    Borkar, V. G.
    2010 IEEE ANTENNAS AND PROPAGATION SOCIETY INTERNATIONAL SYMPOSIUM, 2010,
  • [50] High Aperture Efficiency Profiled Horn at Ku-Band
    Kumar, Ashok
    Jyoti, Rajeev
    2017 IEEE INTERNATIONAL CONFERENCE ON ANTENNA INNOVATIONS & MODERN TECHNOLOGIES FOR GROUND, AIRCRAFT AND SATELLITE APPLICATIONS (IAIM), 2017,