Carbon enhanced cementitious coatings: Alternative anode materials for impressed current cathodic protection systems intended for reinforced concrete

被引:0
|
作者
Jansson, Helen [1 ]
Zhang, Xiaoyan [2 ]
Ye, Lilei [3 ]
Tang, Luping [1 ]
Mohammadi, Amir Saeid [1 ]
Babaahmadi, Arezou [1 ,4 ]
机构
[1] Chalmers Univ Technol, Dept Architecture & Civil Engn, Gothenburg, Sweden
[2] Chalmers Univ Technol, Dept Chem & Chem Engn, Gothenburg, Sweden
[3] Chalmers Industriteknik, Gothenburg, Sweden
[4] Chalmers Univ Technol, Dept Architecture & Civil Engn, S-41296 Gothenburg, Sweden
来源
MATERIALS AND CORROSION-WERKSTOFFE UND KORROSION | 2024年 / 75卷 / 06期
关键词
accelerated durability test; conductive anode material; conductive coating; graphene; graphite; impressed current cathodic protection (ICCP); long-term performance; scanning electron spectroscopy; ELECTROCHEMICAL INVESTIGATIONS; CONDUCTIVE COATINGS; SERVICE LIFE; IMPACT; DEGRADATION;
D O I
10.1002/maco.202314178
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
In this study, the functionality of self-formulated carbon-based conductive coatings (CBCCs) with incorporation of graphite as the anode in an impressed current cathodic protection system is studied. The anode materials are tested and evaluated for long-term durability and performance by an accelerated durability test method. The results show that the functional time is highly dependent on the acceleration factor, and thus the charge passed through the material during testing, as well as the material composition. From the results, there are also indications that the addition of graphene into the CBCC matrix has a positive effect on the homogeneity of the material, but without any major influence on the conductivity and performance. Novel carbon-based conductive coatings, containing micro-graphite and a small amount of graphene, have been developed for use as the anode in an impressed current cathodic protection (ICCP) system. By an accelerated test method, with different acceleration factors, the long-term durability and performance have been investigated, and it is shown that the anode materials can withstand relatively high applied current densities thus making them suitable as the anode in an ICPP system.image
引用
收藏
页码:705 / 718
页数:14
相关论文
共 32 条
  • [21] LABORATORY PERFORMANCE OF ZINC ANODES FOR IMPRESSED CURRENT CATHODIC PROTECTION OF REINFORCED-CONCRETE
    BROUSSEAU, R
    ARNOTT, M
    BALDOCK, B
    CORROSION, 1995, 51 (08) : 639 - 644
  • [22] Protection current distribution in reinforced concrete cathodic protection systems
    Hassanein, AM
    Glass, GK
    Buenfeld, NR
    CEMENT & CONCRETE COMPOSITES, 2002, 24 (01): : 159 - 167
  • [23] Effect of the paste-anode interface under impressed current cathodic protection in concrete structures
    Zhang, Emma Q.
    Tang, Luping
    Bernin, Diana
    Jansson, Helen
    MATERIALS AND CORROSION-WERKSTOFFE UND KORROSION, 2018, 69 (08): : 1104 - 1116
  • [24] Corrosion behavior of carbon fiber reinforced polymer anode in simulated impressed current cathodic protection system with 3% NaCl solution
    Sun, Hongfang
    Wei, Liangliang
    Zhu, Miaochang
    Han, Ningxu
    Zhu, Ji-Hua
    Xing, Feng
    CONSTRUCTION AND BUILDING MATERIALS, 2016, 112 : 538 - 546
  • [25] Impressed-current cathodic protection of steel reinforced concrete filings: Protection criteria and the threshold for hydrogen embrittlement
    Enos, DG
    Williams, AJ
    Clemena, GG
    Scully, JR
    CORROSION, 1998, 54 (05) : 389 - 402
  • [26] Laboratory evaluation of sacrificial anode materials for cathodic protection of reinforced concrete bridges
    Whiting, DA
    Nagi, MA
    Broomfield, JP
    CORROSION, 1996, 52 (06) : 472 - 479
  • [27] Impressed Current Cathodic Protection (ICCP) on reinforced concrete drilled piles buried in soil, Furth, Germany
    Esteves, H.
    Mayer, S.
    CONCRETE SOLUTIONS, 2016, : 131 - 134
  • [28] Current distribution in reinforced concrete cathodic protection system with conductive mortar overlay anode
    Xu, Jing
    Yao, Wu
    CONSTRUCTION AND BUILDING MATERIALS, 2009, 23 (06) : 2220 - 2226
  • [29] STUDY AND APPLICATION OF IMPRESSED CURRENT CATHODIC PROTECTION TECHNIQUE FOR ATMOSPHERICALLY EXPOSED SALT-CONTAMINATED REINFORCED-CONCRETE STRUCTURES
    HONG, DH
    FAN, WG
    LUO, DK
    GE, Y
    ZHU, YX
    ACI MATERIALS JOURNAL, 1993, 90 (01) : 3 - 7
  • [30] Microstructure and interface analyses of novel external anode mortar incorporated calcined hydrotalcite nanoparticles towards an enhanced impressed current cathodic protection
    Mohamed, Ibrahim M. A.
    Wu, Xian-Yang
    Zhu, Ji-Hua
    Abd El-Lateef, Hany M.
    Mousa, Hamouda M.
    Xing, Feng
    JOURNAL OF THE TAIWAN INSTITUTE OF CHEMICAL ENGINEERS, 2023, 145