SPECTROPHOTOMETRIC DETERMINATION OF AMOXICILLIN IN PHARMACEUTICAL FORMULATIONS USING NORMAL AND REVERSE FLOW INJECTION ANALYSIS SYSTEMS: A COMPARISON STUDY

被引:3
|
作者
Mohammed, Tabarak [1 ]
Hadi, Hind [1 ]
机构
[1] Univ Baghdad, Coll Sci, Dept Chem, Baghdad, Iraq
关键词
Amoxicillin; Normal FIA; Reverse FIA; p-Toluidine; Diazotization reaction; ACID; EXTRACTION;
D O I
10.4314/bcse.v38i3.3
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
. The combination of flow injection technique and spectrophotometric detection can be employed for the rapid and low-cost methods for antibiotic assay. In this work, two flow injection analysis (FIA) systems, normal and reverse (nFIA and rFIA), combined with UV-Vis spectrophotometric technique were used for amoxicillin determination in its pure and pharmaceutical preparations. A colorimetric coupling reaction between amoxicillin and diazotized p-toluidine produced a bright yellow azo dye and quantified at a maximum wavelength of 426 nm. For nFIA and rFIA procedures, the amoxicillin calibration graphs had an RSD of less than 2% and were linear in the ranges of 5-200 and 1-140 mu g/mL, respectively. The limits of detection and quantification were 1.41 and 4.71 mu g/mL of amoxicillin for nFIA and 0.39 and 1.31 mu g/mL for rFIA, respectively. The physical and chemical factors that could influence color sensitivity were investigated. Various commercial formulations containing different amounts of amoxicillin were successfully tested using the developed approaches, which demonstrated to be easy, rapid, reproducible, and interference-free.
引用
收藏
页码:577 / 590
页数:14
相关论文
共 50 条
  • [41] Ultrasensitive determination of amoxicillin using chemiluminescence with flow injection analysis
    Xie, XF
    Song, ZH
    SPECTROSCOPY-AN INTERNATIONAL JOURNAL, 2006, 20 (01): : 37 - 43
  • [42] Spectrophotometric determination of sulphide using flow injection analysis
    Yaqoob, M
    Nabi, A
    Wahab, A
    Bano, A
    Shah, SH
    Achakzai, AKK
    JOURNAL OF THE CHEMICAL SOCIETY OF PAKISTAN, 1998, 20 (03): : 214 - 216
  • [43] Reverse flow injection spectrophotometric for determination of aluminium(III)
    Norfun, Poachanee
    Pojanakaroon, Teraboon
    Liawraungrath, Saisunee
    TALANTA, 2010, 82 (01) : 202 - 207
  • [44] Double injection–single detector flow injection spectrophotometric method for simultaneous determination of ascorbic acid and paracetamol in pharmaceutical formulations
    Hunar Yasin Muhammad
    Azad Tawfiq Faizullah
    Journal of the Iranian Chemical Society, 2020, 17 : 111 - 118
  • [45] Flow-injection analysis spectrophotometric determination of bismuth in environmental and pharmaceutical samples
    Agrawal, K
    Mundhara, GL
    Patel, KS
    Hoffmann, P
    ANALYTICAL LETTERS, 2004, 37 (10) : 2163 - 2174
  • [46] The spectrophotometric determination of hydroperoxide and peroxide in a lipid pharmaceutical product by flow injection analysis
    Bloomfield, MS
    ANALYST, 1999, 124 (12) : 1865 - 1871
  • [47] Optimized and validated flow-injection spectrophotometric analysis of topiramate, piracetam and levetiracetam in pharmaceutical formulations
    Hadad, Ghada M.
    Abdel-Salam, Randa A.
    Emara, Samy
    ACTA PHARMACEUTICA, 2011, 61 (04) : 377 - 389
  • [48] FLOW-INJECTION SPECTROPHOTOMETRIC DETERMINATION OF TETRACYCLINE AND DOXYCYCLINE IN PHARMACEUTICAL FORMULATIONS USING CHLORAMINE-T AS OXIDIZING AGENT.
    Rufino, Jose L.
    Weinert, Patricia L.
    Pezza, Helena R.
    Pezza, Leonardo
    QUIMICA NOVA, 2009, 32 (07): : 1764 - U93
  • [49] Flow-injection spectrophotometric determination of dipyrone in pharmaceutical formulations using a solid-phase reactor with copper(II) phosphate
    Bonifacio, Viviane G.
    Fatibello Filho, Orlando
    Marcolino-Junior, Luiz H.
    CENTRAL EUROPEAN JOURNAL OF CHEMISTRY, 2013, 11 (11): : 1830 - 1836
  • [50] Reverse flow injection spectrophotometric determination of iron(III) using chlortetracycline reagent
    Ruengsitagoon, Wirat
    TALANTA, 2008, 74 (05) : 1236 - 1241