Magnetic resonance guided high intensity focused ultrasound for uterine fibroids and adenomyosis has no effect on ovarian reserve

被引:11
|
作者
Otonkoski, Saara [1 ,2 ,5 ]
Sainio, Teija [3 ,4 ]
Mattila, Sami [4 ]
Sequieros, Roberto Blanco [2 ,3 ]
Perheentupa, Antti [1 ,2 ]
Komar, Gaber [2 ,3 ]
Joronen, Kirsi [1 ,2 ]
机构
[1] Turku Univ Hosp, Dept Obstet & Gynecol, Turku, Finland
[2] Univ Turku, Turku, Finland
[3] Turku Univ Hosp, Dept Radiol, Turku, Finland
[4] Turku Univ Hosp, Dept Med Phys, Turku, Finland
[5] Turku Univ Hosp, Dept Obstet & Gynecol, Kiinamyllynkatu 4-8, Turku 20521, Finland
关键词
Fibroid; MR-HIFU; AMH; ovarian reserve; thermal ablation; ANTI-MULLERIAN HORMONE; ARTERY EMBOLIZATION; HYSTERECTOMY; MYOMECTOMY; MARKERS; IMPACT; WOMEN;
D O I
10.1080/02656736.2022.2154575
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Introduction: Uterine fibroids are the most common benign tumors in healthy women. High Intensity Focused Ultrasound (HIFU) is a modern, noninvasive thermal ablation method for treating uterine fibroids. There is increasing evidence that ultrasound guided HIFU (US-HIFU) has no adverse impact on ovarian reserve but little data exists on magnetic resonance guided HIFU (MR-HIFU). There are different options to estimate ovarian reserve, perhaps the most reliable being the measurement of serum Anti-Mullerian hormone (AMH). Material and methods: Seventy-four (74) premenopausal women with serum AMH 0.1 ug/L or over, aged 24-48 and with fibroids or adenomyosis treated with MR-HIFU were enrolled in our study. AMH levels were analyzed before and 3 months after the MR-HIFU treatment. Correlations between AMH level changes and position of fibroids, fibroid volume, non-perfused volume ratio, and treatment energies were studied. Results: The median AMH level before the HIFU treatment was 1.20 (range: 0.1-7.75 ug/L) and after the treatment 1.23 (range: 0.1-8.51 ug/L). No significant change was detected (p = .90). The patients were divided in three subgroups depending on the baseline AMH levels. The changes were not significant in any of the subgroups. Neither did the location of the treated fibroid affect the change of AMH levels nor the total energy used during treatment. Conclusions: MR-HIFU does not compromise the ovarian reserve. Neither the location of the treated fibroid nor the total energy used during MR-HIFU had any effect on the change of AMH levels.
引用
收藏
页数:6
相关论文
共 50 条
  • [21] Effect of Paracervical Block Before Ultrasound Guided High Intensity Focused Ultrasound Treatment in Uterine Fibroids and Adenomyosise
    Lee, Jae-Seong
    Lee, Kye-Hwa
    Kim, Tae-Eung
    CLINICAL AND EXPERIMENTAL OBSTETRICS & GYNECOLOGY, 2022, 49 (08):
  • [22] Efficacy, Efficiency, and Safety of Magnetic Resonance-Guided High-Intensity Focused Ultrasound for Ablation of Uterine Fibroids: Comparison with Ultrasound-Guided Method
    Wang, Yi
    Wang, Zhi-Biao
    Xu, Yong-Hua
    KOREAN JOURNAL OF RADIOLOGY, 2018, 19 (04) : 724 - 732
  • [23] Cost-effectiveness of magnetic resonance guided focused ultrasound for the treatment of uterine fibroids
    O'Sullivan, Amy K.
    Thompson, David
    Chu, Paula
    Lee, David W.
    Stewart, Elizabeth A.
    Weinstein, Milton C.
    INTERNATIONAL JOURNAL OF TECHNOLOGY ASSESSMENT IN HEALTH CARE, 2009, 25 (01) : 14 - 25
  • [24] ECONOMIC EVALUATION OF MAGNETIC RESONANCE GUIDED FOCUSED ULTRASOUND IN PATIENTS WITH UTERINE FIBROIDS IN GERMANY
    Alvarez-Ossorio, L.
    Burkowitz, J.
    Nackunstz, I
    Brueggenjuergen, B.
    VALUE IN HEALTH, 2011, 14 (07) : A261 - A262
  • [25] Magnetic Resonance-Guided Focused Ultrasound Surgery (MRgFUS) of Uterine Fibroids in Singapore
    Han, Nian-Lin R.
    Ong, Chiou Li
    ANNALS ACADEMY OF MEDICINE SINGAPORE, 2014, 43 (11) : 550 - 558
  • [26] Targeted Vessel Ablation for More Efficient Magnetic Resonance-Guided High-Intensity Focused Ultrasound Ablation of Uterine Fibroids
    Voogt, Marianne J.
    van Stralen, Marijn
    Ikink, Marlijne E.
    Deckers, Roel
    Vincken, Koen L.
    Bartels, Lambertus W.
    Mali, Willem P. Th M.
    van den Bosch, Maurice A. A. J.
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2012, 35 (05) : 1205 - 1210
  • [27] Targeted Vessel Ablation for More Efficient Magnetic Resonance-Guided High-Intensity Focused Ultrasound Ablation of Uterine Fibroids
    Marianne J. Voogt
    Marijn van Stralen
    Marlijne E. Ikink
    Roel Deckers
    Koen L. Vincken
    Lambertus W. Bartels
    Willem P. Th. M. Mali
    Maurice A. A. J. van den Bosch
    CardioVascular and Interventional Radiology, 2012, 35 : 1205 - 1210
  • [28] An image-guided high intensity focused ultrasound device for uterine fibroids treatment
    Chan, AH
    Fujimoto, VY
    Moore, DE
    Martin, RW
    Vaezy, S
    MEDICAL PHYSICS, 2002, 29 (11) : 2611 - 2620
  • [29] MRI parameters for predicting the effect of ultrasound-guided high-intensity focused ultrasound in the ablation of uterine fibroids
    Liao, L.
    Xu, Y. H.
    Bai, J.
    Zhan, P.
    Zhou, J.
    Li, M. X.
    Zhang, Y.
    CLINICAL RADIOLOGY, 2023, 78 (01) : 61 - 69
  • [30] Magnetic resonance imaging parameters in predicting the ablative efficiency of high-intensity focused ultrasound for uterine fibroids
    Gong, Chunmei
    Lin, Zhenjiang
    Lv, Fajin
    Zhang, Lian
    Wang, Zhibiao
    INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2021, 38 (01) : 523 - 531