Overcoming the Impedance Range Limitations of Portable Bioelectrical Impedance Spectroscopy Clinical Devices

被引:0
|
作者
Montalibet, Amalric [1 ]
Massot, Bertrand [1 ]
Gehin, Claudine [1 ]
McAdams, Eric [1 ]
机构
[1] Univ Lyon, INSA Lyon, ECL, CNRS,UCBL,CPE Lyon,INL,UMR5270,DSE Team,Biomed Se, F-69621 Villeurbanne, France
来源
2023 45TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE & BIOLOGY SOCIETY, EMBC | 2023年
关键词
D O I
10.1109/EMBC40787.2023.10340265
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Several portable commercial bioimpedance spectroscopy (BIS) devices are used in clinical research, but are limited by their reduced impedance measuring range to less demanding four-electrode configuration measurements. Some of these devices provide raw bioimpedance data for research purposes. The SFB7 device from ImpediMed (R) is a typical portable clinical device which perform 256 measurement points from 3 kHz to 1 MHz, providing for each point the resistance R and the reactance X. Its main drawback is its impedance range, limited to only 1100 Omega, making it less suitable for more demanding, higher impedance, two-electrode measurements which are potentially of great clinical interest. Some benchtop reference devices have larger frequency and impedance ranges than the SFB7 but are not portable and are not designed specifically for BIS measurement on humans. This article proposes a method to overcome the impedance range limitation of the SFB7 by connecting in parallel to the investigated bioimpedance a fixed and known impedance, whose value (and hence that of the total measured impedance) is within the device's range. The investigated impedance is then calculated by eliminating the contribution of the known impedance via a post processing of the data. This concept has been successfully tested on a physical model, and an in vivo example has validated the practicality of performing demanding two-electrode measurements on individuals using a SFB7, with relative errors of R and X inferior to 2.5% and 7% respectively.
引用
收藏
页数:4
相关论文
共 50 条
  • [21] The bioelectrical impedance analysis and sarcopenia: Devices & standardization protocols
    Catikkas, Nezahat Muge
    Safer, Umut
    CLINICAL NUTRITION, 2023, 42 (12) : 2484 - 2485
  • [22] Competency in home body fat monitoring by portable devices based on bioelectrical impedance analysis: A pilot study
    Mondal, Himel
    Mondal, Shaikat
    Baidya, Chayan
    JOURNAL OF EDUCATION AND HEALTH PROMOTION, 2019, 8 (01)
  • [23] Limitations and validation of bioelectrical impedance analysis in morbidly obese patients
    Coppini, LZ
    Waitzberg, DL
    Campos, ACL
    CURRENT OPINION IN CLINICAL NUTRITION AND METABOLIC CARE, 2005, 8 (03): : 329 - 332
  • [24] Clinimetrics: Bioelectrical Impedance Analysis in Clinical Practice
    Ferguson, Clare E.
    Lambell, Kate J.
    JOURNAL OF PHYSIOTHERAPY, 2022, 68 (04) : 280 - 280
  • [25] Bioelectrical impedance in the clinical evaluation of liver disease
    Schloerb, PR
    Forster, J
    Delcore, R
    Kindscher, JD
    AMERICAN JOURNAL OF CLINICAL NUTRITION, 1996, 64 (03): : 510 - 514
  • [26] Clinical usefulness of segmental bioelectrical impedance analysis
    Sakamoto, Y
    Sakamoto, N
    Ikeda, Y
    Nishizawa, M
    Heymsfield, SB
    OBESITY RESEARCH, 2000, 8 : 111S - 111S
  • [27] Circuit Architecture for Electrical Impedance Spectroscopy Instrumentation to Address Electrode Impedance Mismatch in Clinical Devices
    Healey, T. Jamie
    Billinge, Emily Rose
    Alix, James J. P.
    Kadirkamanathan, Visakan
    Kemp, Charlotte R.
    IEEE SENSORS JOURNAL, 2021, 21 (20) : 22258 - 22269
  • [28] Assessment of Bilateral Limb Lymphedema by Bioelectrical Impedance Spectroscopy
    Ward, Leigh
    Winall, Ann
    Isenring, Elizabeth
    Hills, Andrew
    Czerniec, Sharon
    Dylke, Elizabeth
    Kilbreath, Sharon
    INTERNATIONAL JOURNAL OF GYNECOLOGICAL CANCER, 2011, 21 (02) : 409 - 418
  • [29] Variability of k terms in bioelectrical impedance spectroscopy -: Reply
    Ellis, KJ
    AMERICAN JOURNAL OF CLINICAL NUTRITION, 2000, 71 (06): : 1617 - 1618
  • [30] BroadBand Excitation for Bioelectrical Impedance Spectroscopy: A Comparative Study
    Universidade de Coimbra