Overcoming the Impedance Range Limitations of Portable Bioelectrical Impedance Spectroscopy Clinical Devices

被引:0
|
作者
Montalibet, Amalric [1 ]
Massot, Bertrand [1 ]
Gehin, Claudine [1 ]
McAdams, Eric [1 ]
机构
[1] Univ Lyon, INSA Lyon, ECL, CNRS,UCBL,CPE Lyon,INL,UMR5270,DSE Team,Biomed Se, F-69621 Villeurbanne, France
来源
2023 45TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE & BIOLOGY SOCIETY, EMBC | 2023年
关键词
D O I
10.1109/EMBC40787.2023.10340265
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Several portable commercial bioimpedance spectroscopy (BIS) devices are used in clinical research, but are limited by their reduced impedance measuring range to less demanding four-electrode configuration measurements. Some of these devices provide raw bioimpedance data for research purposes. The SFB7 device from ImpediMed (R) is a typical portable clinical device which perform 256 measurement points from 3 kHz to 1 MHz, providing for each point the resistance R and the reactance X. Its main drawback is its impedance range, limited to only 1100 Omega, making it less suitable for more demanding, higher impedance, two-electrode measurements which are potentially of great clinical interest. Some benchtop reference devices have larger frequency and impedance ranges than the SFB7 but are not portable and are not designed specifically for BIS measurement on humans. This article proposes a method to overcome the impedance range limitation of the SFB7 by connecting in parallel to the investigated bioimpedance a fixed and known impedance, whose value (and hence that of the total measured impedance) is within the device's range. The investigated impedance is then calculated by eliminating the contribution of the known impedance via a post processing of the data. This concept has been successfully tested on a physical model, and an in vivo example has validated the practicality of performing demanding two-electrode measurements on individuals using a SFB7, with relative errors of R and X inferior to 2.5% and 7% respectively.
引用
收藏
页数:4
相关论文
共 50 条
  • [1] A Prototype Portable System for Bioelectrical Impedance Spectroscopy
    He, Jian-xin
    Wang, Zhong-yi
    Shi, Yu-ling
    Qin, Yang
    Zhao, Dong-jie
    Huang, Lan
    SENSOR LETTERS, 2011, 9 (03) : 1151 - 1156
  • [2] Design of the Portable Instrument for Bioelectrical Impedance
    Chen, Bo
    Wu, Jinfeng
    Gao, Xiu-e
    Zheng, Qingguo
    2016 9TH INTERNATIONAL CONGRESS ON IMAGE AND SIGNAL PROCESSING, BIOMEDICAL ENGINEERING AND INFORMATICS (CISP-BMEI 2016), 2016, : 1626 - 1631
  • [3] Design of a Portable Bioelectrical Impedance Measurement System
    Lu, Yi
    Huo, Chengyu
    He, Aijun
    FUTURE MATERIALS ENGINEERING AND INDUSTRY APPLICATION, 2012, 365 : 409 - +
  • [4] Repeatability of Bioelectrical Impedance Spectroscopy in Preterm Infants for Clinical Use
    Kanazawa, Hoshinori
    Kawai, Masahiko
    Iwanaga, Kougorou
    Yamada, Yosuke
    Heike, Toshio
    INTERNATIONAL JOURNAL OF OBESITY, 2011, 35 : S60 - S60
  • [5] Bioelectrical impedance spectroscopy and body composition
    Chumlea, WC
    Siervogel, RM
    Wu, YX
    Hall, G
    Guo, SS
    IN VIVO BODY COMPOSITION STUDIES, 2000, 904 : 210 - 213
  • [6] THE CALIBRATION OF A BIOELECTRICAL IMPEDANCE SPECTROSCOPY DEVICE
    Choi, JungHun
    PROCEEDINGS OF THE 2021 DESIGN OF MEDICAL DEVICES CONFERENCE (DMD2021), 2021,
  • [7] Assessment of lymphedema by bioelectrical impedance spectroscopy
    Ward, Leigh C.
    JAPAN JOURNAL OF NURSING SCIENCE, 2011, 8 (01) : 108 - 108
  • [8] Portable devices for periodic monitoring of bioelectrical impedance along meridian pathways in healthy individuals
    Xu, Yu-Chen
    Cao, Xiu-Yan
    Liu, Shuai
    Liu, Bo
    Chen, Hao
    Cheng, Min
    Ye, Wei-Hua
    BIOMEDICAL ENGINEERING ONLINE, 2025, 24 (01)
  • [9] Analysis of concordance between the bioelectrical impedance vector analysis and the bioelectrical impedance spectroscopy in haemodialysis patients
    Teruel-Briones, Jose L.
    Fernandez-Lucas, Milagros
    Ruiz-Roso, Gloria
    Sanchez-Ramirez, Humberto
    Rivera-Gorrin, Maite
    Gomis-Couto, Antonio
    Rodriguez-Mendiola, Nuria
    Quereda, Carlos
    NEFROLOGIA, 2012, 32 (03): : 389 - 395
  • [10] PORTABLE ANALYZER FOR IMPEDANCE SPECTROSCOPY
    Hoja, Jerzy
    Lentka, Grzegorz
    XIX IMEKO WORLD CONGRESS: FUNDAMENTAL AND APPLIED METROLOGY, PROCEEDINGS, 2009, : 497 - 502