Results of new-generation balloon vs. self-expandable transcatheter heart valves for bicuspid aortic valve stenosis

被引:1
|
作者
Deutsch, Oliver [1 ]
Vitanova, Keti [1 ]
Ruge, Hendrik [1 ]
Erlebach, Magdalena [1 ]
Krane, Markus [2 ]
Lange, Ruediger [1 ]
机构
[1] German Heart Ctr Munich, Dept Cardiovasc Surg, Munich, Germany
[2] Yale Sch Med, Dept Surg, Div Cardiac Surg, New Haven, CT USA
来源
关键词
TAVR - transcatheter aortic valve replacement; bicuspid aortic valve (BAV); balloon-expandable valve; self-expandable valve; retrospective cohort study; END-POINT DEFINITIONS; PARAVALVULAR REGURGITATION; REPLACEMENT; IMPLANTATION; ECHOCARDIOGRAPHY; CLASSIFICATION; CALCIFICATION; OUTCOMES; ANNULUS;
D O I
10.3389/fcvm.2023.1252163
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BackgroundData comparing new-generation self-expandable (SEV, Evolut R/PRO) vs. balloon-expandable (BEV, SAPIEN 3/3Ultra) transcatheter heart valve replacement (TAVR) in bicuspid aortic valve stenosis (BAV) is limited. Our aim was to compare 30-day results of SEV and BEV implantations in patients with BAV.MethodsA total of 2009 patients underwent TAVR between April 2015 and June 2021 at our Centre. From our institutional registry, we identified 106 consecutive patients with BAV who underwent TAVR using SEV and BEV.ResultsA 106 patients (n = 68 BEV; n = 38 SEV) were included. Mean age was 74.6 & PLUSMN; 8.8 years (BEV) vs.75.3 & PLUSMN; 8.7 years (SEV) (p = 0.670) and Society of Thoracic Surgeons score was 2.6 & PLUSMN; 1.9 (BEV) vs. 2.6 & PLUSMN; 1.6 (SEV) (p = 0.374), respectively. Device landing zone calcium volume (DLZ-CV) was 1168 & PLUSMN; 811 vs. 945 & PLUSMN; 850 mm3 (p = 0.192). Valve Academic Research Consortium (VARC)-3 device success at 30 days was similar (BEV 80.9% vs. SEV 86.8%; p = 0.433). More post-dilatations were performed in SEVs (23.5% BEV vs. 52.6% SEV; p = 0.002). Overall mean gradient at 30 days follow-up was 11.9 & PLUSMN; 4.6 mmHG (BEV) vs. 9.2 & PLUSMN; 3.0 mmHG (SEV) (p = 0.002). A mild-moderate degree of paravalvular leak (PVL) was detected more often in the SEV group (7.4% vs. 13.2%; p = 0.305). A trend towards higher rate of permanent pacemaker implantation was observed in SEV (11.8% vs. 23.7%; p = 0.109).ConclusionsTreatment of BAV revealed similar performance using BEV and SEV. In this retrospective cohort study, hemodynamics were more favorable with the SEV, although there was a trend toward more PVL and significantly more post-dilations.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] REPLY: Outcomes After Transcatheter Aortic Valve Replacement With Balloon-Expandable Versus Self-Expandable Valves CHOICE Trial Results
    Abdel-Wahab, Mohamed
    Richardt, Gert
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2016, 67 (02) : 236 - 237
  • [42] Differences in Pressure Recovery Between Balloon Expandable and Self-expandable Transcatheter Aortic Valves
    Hoda Hatoum
    Rebecca T. Hahn
    Scott Lilly
    Lakshmi Prasad Dasi
    Annals of Biomedical Engineering, 2020, 48 : 860 - 867
  • [43] Observed New Onset of Heart Block in the Self-Expandable and Balloon-Expandable Transcatheter Aortic Valve Implantation.
    Liang, Michael
    Devlin, Gerard
    Pasupati, Sanjeevan
    AMERICAN JOURNAL OF CARDIOLOGY, 2011, 107 (8A): : 17A - 17A
  • [44] Impact of balloon aortic valvuloplasty on transcatheter aortic valve implantation with self-expandable valve
    Vavuranakis, Manolis
    Lavda, Maria
    Vrachatis, Dimitrios
    Papaioannou, Theodore G.
    Kalogeras, Konstantinos
    Kolokathis, Angelos-Michail
    Kariori, Maria
    Lilly, Scott
    Siasos, Gerasimos
    Oikonomou, Evangelos
    Toutouzas, Konstantinos
    Stasinopoulou, Myrsini
    Deliveliotis, Konstantinos
    Tousoulis, Dimitrios
    JOURNAL OF CARDIOLOGY, 2017, 69 (1-2) : 245 - 252
  • [45] New-generation Myval transcatheter heart valve in severe aortic stenosis
    Akodad, Mariama
    Gall, Emmanuel
    LANCET, 2024, 403 (10445): : 2664 - 2665
  • [46] CLINICAL OUTCOMES OF THE BALLOON-EXPANDABLE VS SELF-EXPANDABLE VALVES IN PATIENTS UNDERGOING TRANSCATHETER AORTIC VALVE REPLACEMENT - A META-ANALYSIS
    Gan, Eugene
    Keh, Yann Shan
    Fei, Gao
    Ewe, See Hooi
    Amanullah, Mohammed Rizwan
    Chao, Victor
    Lim, Soo Teik
    Ho, Kay Woon
    Yap, Jonathan
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2022, 79 (09) : 685 - 685
  • [47] Comparison of Balloon-Expandable vs Self-expandable Valves in Patients Undergoing Transcatheter Aortic Valve Replacement The CHOICE Randomized Clinical Trial
    Abdel-Wahab, Mohamed
    Mehilli, Julinda
    Frerker, Christian
    Neumann, Franz-Josef
    Kurz, Thomas
    Toelg, Ralph
    Zachow, Dirk
    Guerra, Elena
    Massberg, Steffen
    Schaefer, Ulrich
    El-Mawardy, Mohamed
    Richardt, Gert
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2014, 311 (15): : 1503 - 1514
  • [48] Balloon-expandable or self-expandable transcatheter heart valves. Which are best?
    Webb, John
    Wood, David
    Sathananthan, Janarthanan
    Landes, Uri
    EUROPEAN HEART JOURNAL, 2020, 41 (20) : 1900 - 1902
  • [49] Differences in blood flow dynamics between balloon- and self-expandable valves in patients with aortic stenosis undergoing transcatheter aortic valve replacement
    Yuki Takahashi
    Kiwamu Kamiya
    Toshiyuki Nagai
    Satonori Tsuneta
    Noriko Oyama-Manabe
    Takeshi Hamaya
    Sho Kazui
    Yutaro Yasui
    Kohei Saiin
    Seiichiro Naito
    Yoshifumi Mizuguchi
    Sakae Takenaka
    Atsushi Tada
    Suguru Ishizaka
    Yuta Kobayashi
    Kazunori Omote
    Takuma Sato
    Yasushige Shingu
    Kohsuke Kudo
    Satoru Wakasa
    Toshihisa Anzai
    Journal of Cardiovascular Magnetic Resonance, 25
  • [50] Meta-Analysis Comparing Transcatheter Aortic Valve Implantation With Balloon Versus Self-Expandable Valves
    Osman, Mohammed
    Ghaffar, Yasir Abdul
    Saleem, Maryam
    Kheiri, Babikir
    Osman, Khansa
    Munir, Muhammad Bilal
    Alkhouli, Mohamad
    AMERICAN JOURNAL OF CARDIOLOGY, 2019, 124 (08): : 1252 - 1256