Effect of Electrocautery and Laser Treatment on the Composition and Morphology of Surface-Modified Titanium Implants

被引:2
|
作者
Lee, Jin-Seok [1 ]
Son, Keunbada [2 ]
Hwang, Sung-Min [1 ]
Son, Young-Tak [2 ,3 ]
Kim, Yong-Gun [1 ]
Suh, Jo-Young [1 ]
Hwang, Jun Ho [4 ]
Kwon, Sung-Min [4 ]
Lee, Jong Hoon [4 ]
Kim, Hyun Deok [5 ]
Lee, Kyu-Bok [6 ]
Lee, Jae-Mok [1 ]
机构
[1] Kyungpook Natl Univ, Sch Dent, Dept Periodontol, Daegu 41940, South Korea
[2] Kyungpook Natl Univ, Adv Dent Device Dev Inst A3DI, Daegu 41940, South Korea
[3] Kyungpook Natl Univ, Grad Sch, Dept Dent Sci, Daegu 41940, South Korea
[4] Kyungpook Natl Univ, Inst Adv Convergence Technol, Daegu 41061, South Korea
[5] Kyungpook Natl Univ, Sch Elect Engn, Daegu 41566, South Korea
[6] Kyungpook Natl Univ, Sch Dent, Dept Prosthodont, Daegu 41940, South Korea
来源
BIOENGINEERING-BASEL | 2023年 / 10卷 / 11期
基金
新加坡国家研究基金会;
关键词
dental implant; electrocautery treatment; laser treatment; surface roughness;
D O I
10.3390/bioengineering10111251
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
The purpose of this study was to investigate the effects of different peri-implantitis treatment methods (Er,Cr:YSGG laser, diode laser, and electrocautery) on various titanium implant surfaces: machined; sandblasted, large-grit, and acid-etched; and femtosecond laser-treated surfaces. Grade 4 titanium (Ti) disks, with a diameter of 10 mm and a thickness of 1 mm, were fabricated and treated using the aforementioned techniques. Subsequently, each treated group of disks underwent different peri-implantitis treatment methods: Er,Cr:YSGG laser (Biolase, Inc., Foothill Ranch, CA, USA), diode laser (Biolase, Inc., Foothill Ranch, CA, USA), and electrocautery (Ellman, Hicksville, NY, USA). Scanning electron microscopy, energy-dispersive X-ray spectroscopy, and wettability were used to characterize the chemical compositions and surfaces of the treated titanium surfaces. Significant changes in surface roughness were observed in both the electrocautery (Sa value of machined surface = 0.469, SLA surface = 1.569, femtosecond laser surface = 1.741, and p = 0.025) and Er,Cr:YSGG laser (Ra value of machined surface = 1.034, SLA surface = 1.380, femtosecond laser surface = 1.437, and p = 0.025) groups. On femtosecond laser-treated titanium implant surfaces, all three treatment methods significantly reduced the surface contact angle (control = 82.2 degrees, diode laser = 74.3 degrees, Er,Cr:YSGG laser = 73.8 degrees, electrocautery = 76.2 degrees, and p = 0.039). Overall, Er,Cr:YSGG laser and electrocautery treatments significantly altered the surface roughness of titanium implant surfaces. As a result of surface composition after different peri-implantitis treatment methods, relative to the diode laser and electrocautery, the Er,Cr:YSGG laser increased oxygen concentration. The most dramatic change was observed after Er:Cr;YSGG laser treatment, urging caution for clinical applications. Changes in surface composition and wettability were observed but were not statistically significant. Further research is needed to understand the biological implications of these peri-implantitis treatment methods.
引用
收藏
页数:14
相关论文
共 50 条
  • [31] Oxidation behavior of surface-modified titanium for titanium-ceramic restorations
    Wang, RR
    Fung, KK
    JOURNAL OF PROSTHETIC DENTISTRY, 1997, 77 (04): : 423 - 434
  • [32] Deposition of magnesium on surface-modified titanium for biomedical applications
    Prantik Roy Chowdhury
    Sahar Vahabzadeh
    Journal of Materials Research, 2022, 37 : 2635 - 2644
  • [33] Effect of surface treatment on unalloyed titanium implants: Spectroscopic analyses
    Kilpadi, DV
    Raikar, GN
    Liu, J
    Lemons, JE
    Vohra, Y
    Gregory, JC
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1998, 40 (04): : 646 - 659
  • [34] Corrosion Electrochemical Behavior of Surface-Modified Titanium Alloys
    V. I. Pokhmurs’kyi
    O. S. Kalakhan
    H. H. Okhota
    Materials Science, 2005, 41 : 1 - 6
  • [35] Deposition of magnesium on surface-modified titanium for biomedical applications
    Chowdhury, Prantik Roy
    Vahabzadeh, Sahar
    JOURNAL OF MATERIALS RESEARCH, 2022, 37 (16) : 2635 - 2644
  • [36] Corrosion electrochemical behavior of surface-modified titanium alloys
    Pokhmurs'kyi, VI
    Kalakhan, OS
    Okhota, HH
    MATERIALS SCIENCE, 2005, 41 (01) : 1 - 6
  • [37] In vitro biocompatibility evaluation of surface-modified titanium alloys
    Treves, Cristina
    Martinesi, Maria
    Stio, Maria
    Gutierrez, Alejandro
    Antonio Jimenez, Jose
    Francisca Lopez, Maria
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2010, 92A (04) : 1623 - 1634
  • [38] ELECTROCHEMICAL CORROSION ANALYSES AND CHARACTERIZATION OF SURFACE-MODIFIED TITANIUM
    ONG, JL
    LUCAS, LC
    RAIKAR, GN
    GREGORY, JC
    APPLIED SURFACE SCIENCE, 1993, 72 (01) : 7 - 13
  • [39] Surface composition and topography of titanium alloy implants
    Wieland, M
    Sittig, C
    Textor, M
    Schenk, V
    Ha, SW
    Keller, BA
    Wintermantel, E
    Spencer, ND
    ECASIA 97: 7TH EUROPEAN CONFERENCE ON APPLICATIONS OF SURFACE AND INTERFACE ANALYSIS, 1997, : 139 - 142
  • [40] Corneal epithelialisation on surface-modified hydrogel implants Artificial cornea
    Ma, Aihua
    Zhao, Bojun
    Bentley, Adam J.
    Brahma, Arun
    MacNeil, Sheila
    Martin, Francis L.
    Rimmer, Stephen
    Fullwood, Nigel J.
    JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2011, 22 (03) : 663 - 670