共 50 条
Safety and Efficacy of OPN Balloon in Patients With Calcified Coronary Artery Disease
被引:5
|作者:
Senguttuvan, Nagendra Boopathy
[1
,4
]
Singh, Harsimran
[1
]
Kumar, Balakrishnan Vinod
[1
]
Kongara, Rahul Chowdary
[1
]
Abdulkader, Rizwan Suliankatchi
[2
]
Anandaram, Asuwin
[3
]
Krishnamurthy, Preetam
[1
]
Balasubramaniyan, Jayanthy Venkata
[1
]
Sadhanandham, Shanmugasundram
[1
]
Ramesh, Sankaran
[1
]
Manokar, Panchanatham
[1
]
Muralidharan, Thoddi Ramamurthy
[1
]
Murthy, Jayanthy S. N.
[1
]
Thanikachalam, Sadagopan
[1
]
机构:
[1] Sri Ramachandra Inst Higher Educ & Res SRIHER, Dept Cardiol, 1 Ramachandra Nagar,Porur, Chennai 600116, Tamil Nadu, India
[2] Natl Inst Epidemiol, ICMR, Scientist D, Chennai, India
[3] Sri Ramachandra Inst Higher Educ & Res SRIHER, Dept Clin Res, 1,Ramachandra Nagar,Porur, Chennai 600116, Tamil Nadu, India
[4] SRIHER, Dept Cardiol, Chennai, India
关键词:
OPN balloon;
Calcified lesions;
Stent expansion;
CAD;
SIROLIMUS-ELUTING STENTS;
LESIONS;
D O I:
10.1016/j.carrev.2023.02.018
中图分类号:
R5 [内科学];
学科分类号:
1002 ;
100201 ;
摘要:
Background: Patients with symptomatic calcified coronary lesions have poor outcomes. Such lesions require additional atherectomy devices for bed preparation. Aim: To assess the safety and efficacy of OPN balloon in patients with calcified coronary lesions.Methods: This is an investigator-initiated, prospective, observational study. The primary outcome of the study was a procedural success.Results: We studied 71 patients (133 lesions). Maximum lesions were located in LAD [46.6 %]. The OPN balloon was used for pre-dilatation alone in 28.6 % (Pre-stent OPN group), post-dilatation alone in 63.2 % of lesions (Post-stent OPN group), and in both situations in 8.3 % of lesions with procedural success in 98.5 % of patients. Further dilatation with different NC balloons was required in both groups (30 %). The median (IQR) OPN balloon diameter in the pre-and post-stent OPN group were 2.5 (2.5, 3.0) and 3.0 (3.0,3.0) mm (p = 0.001), respectively. The difference between the diameter of the stent and OPN balloon used in pre-stent OPN group was 0.5 (0.2, 0.5) mm while it was 0.0 (0.0,0.2) mm in the post-stent OPN group (p < 0.001). Eight complications and two deaths occured. Distal shaft rupture was also noticed. Conclusion: OPN balloon is safe, and effective in treating calcified coronary lesions. We propose to undersize the balloon by 0.5 mm for pre-dilatation followed by 0.25 mm larger NC balloon if needed. In the post-dilatation group, use a 1:1 size balloon in a non-tortuous straight segment. Use imaging especially when (1) the pressure taken more than the rated burst pressure, (2) an OPN balloon size is >= 3 mm (3) using 1:1 size OPN balloon in a tortuous segment.(c) 2023 Elsevier Inc. All rights reserved.
引用
收藏
页码:25 / 30
页数:6
相关论文