Safety and Efficacy of OPN Balloon in Patients With Calcified Coronary Artery Disease

被引:5
|
作者
Senguttuvan, Nagendra Boopathy [1 ,4 ]
Singh, Harsimran [1 ]
Kumar, Balakrishnan Vinod [1 ]
Kongara, Rahul Chowdary [1 ]
Abdulkader, Rizwan Suliankatchi [2 ]
Anandaram, Asuwin [3 ]
Krishnamurthy, Preetam [1 ]
Balasubramaniyan, Jayanthy Venkata [1 ]
Sadhanandham, Shanmugasundram [1 ]
Ramesh, Sankaran [1 ]
Manokar, Panchanatham [1 ]
Muralidharan, Thoddi Ramamurthy [1 ]
Murthy, Jayanthy S. N. [1 ]
Thanikachalam, Sadagopan [1 ]
机构
[1] Sri Ramachandra Inst Higher Educ & Res SRIHER, Dept Cardiol, 1 Ramachandra Nagar,Porur, Chennai 600116, Tamil Nadu, India
[2] Natl Inst Epidemiol, ICMR, Scientist D, Chennai, India
[3] Sri Ramachandra Inst Higher Educ & Res SRIHER, Dept Clin Res, 1,Ramachandra Nagar,Porur, Chennai 600116, Tamil Nadu, India
[4] SRIHER, Dept Cardiol, Chennai, India
关键词
OPN balloon; Calcified lesions; Stent expansion; CAD; SIROLIMUS-ELUTING STENTS; LESIONS;
D O I
10.1016/j.carrev.2023.02.018
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Patients with symptomatic calcified coronary lesions have poor outcomes. Such lesions require additional atherectomy devices for bed preparation. Aim: To assess the safety and efficacy of OPN balloon in patients with calcified coronary lesions.Methods: This is an investigator-initiated, prospective, observational study. The primary outcome of the study was a procedural success.Results: We studied 71 patients (133 lesions). Maximum lesions were located in LAD [46.6 %]. The OPN balloon was used for pre-dilatation alone in 28.6 % (Pre-stent OPN group), post-dilatation alone in 63.2 % of lesions (Post-stent OPN group), and in both situations in 8.3 % of lesions with procedural success in 98.5 % of patients. Further dilatation with different NC balloons was required in both groups (30 %). The median (IQR) OPN balloon diameter in the pre-and post-stent OPN group were 2.5 (2.5, 3.0) and 3.0 (3.0,3.0) mm (p = 0.001), respectively. The difference between the diameter of the stent and OPN balloon used in pre-stent OPN group was 0.5 (0.2, 0.5) mm while it was 0.0 (0.0,0.2) mm in the post-stent OPN group (p < 0.001). Eight complications and two deaths occured. Distal shaft rupture was also noticed. Conclusion: OPN balloon is safe, and effective in treating calcified coronary lesions. We propose to undersize the balloon by 0.5 mm for pre-dilatation followed by 0.25 mm larger NC balloon if needed. In the post-dilatation group, use a 1:1 size balloon in a non-tortuous straight segment. Use imaging especially when (1) the pressure taken more than the rated burst pressure, (2) an OPN balloon size is >= 3 mm (3) using 1:1 size OPN balloon in a tortuous segment.(c) 2023 Elsevier Inc. All rights reserved.
引用
收藏
页码:25 / 30
页数:6
相关论文
共 50 条
  • [1] SAFETY AND EFFICACY OF CORONARY INTRAVASCULAR LITHOTRIPSY FOR CALCIFIED CORONARY ARTERY DISEASE
    Alraies, M. Chadi
    Sattar, Yasar
    Suleiman, Abdul-Rahman
    Ullah, Waqas
    Ahmad, Bachar
    Zghouzi, Mohamed
    Doshi, Rajkumar
    Gardi, Delair
    Ali, Omar
    Hakim, Zaher
    Asfour, Abedelrahim
    Aljaroudi, Wael
    Qureshi, Waqas
    Elgendy, Islam
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2021, 77 (18) : 1218 - 1218
  • [2] Procedural Safety and Efficacy of Super-High Pressure OPN Balloon in Patients With Moderate to Severely Calcified Coronary Artery Disease - A Single-Centre, Real-World Experience
    Senguttuvan, Nagendra Boopathy
    Singh, Harsimran
    Balakrishnan, Vinodkumar
    Balasubramanian, J. V.
    Sankaran, Ramesh
    Shanmugasundaram, Sadhanandham
    Panchanantham, Manokar
    Muralidharan, T. R.
    JACC-CARDIOVASCULAR INTERVENTIONS, 2023, 16 (04) : S23 - S24
  • [3] EFFICACY AND SAFETY OF INTRAVASCULAR LITHOTRIPSY IN CALCIFIED CORONARY ARTERY DISEASE; A SYSTEMATIC REVIEW AND METAANALYSIS
    Mhanna, Mohammed
    Beran, Azizullah
    Nazir, Salik
    Sajdeya, Omar
    Srour, Omar
    Eltahawy, Ehab
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2021, 77 (18) : 910 - 910
  • [4] Safety and efficacy of bariatric surgery in patients with coronary artery disease
    Lopez-Jimenez, F
    Bhatia, S
    Collazo-Clavell, ML
    Sarr, MG
    Somers, VK
    MAYO CLINIC PROCEEDINGS, 2005, 80 (09) : 1157 - 1162
  • [5] SAFETY AND EFFICACY OF INTRAVASCULAR LITHOTRIPSY IN UNPROTECTED CALCIFIED LEFT MAIN CORONARY ARTERY
    Arshad, Muhammad Muneeb
    Shahid, Farhan
    Hesse, Kerrick
    Ahmed, Javed M.
    HEART, 2023, 109 : A63 - A65
  • [6] Safety and efficacy of chocolate balloon in the treatment of infrapopliteal artery disease
    Wu, Ridong
    Yang, Qingqi
    Wang, Mian
    Li, Zilun
    Yao, Chen
    Chang, Guangqi
    CVIR ENDOVASCULAR, 2025, 8 (01)
  • [7] Safety and efficacy of exercise training after coronary stenting in patients with stable coronary artery disease
    Soga, Y.
    Ando, K.
    Shirai, S.
    Sakai, K.
    Kondo, K.
    Yokoi, H.
    Iwabuchi, M.
    Nobuyoshi, M.
    EUROPEAN HEART JOURNAL, 2011, 32 : 492 - 492
  • [8] Safety and Efficacy of Exercise Training After Coronary Stenting in Patients with Stable Coronary Artery Disease
    Soga, Yoshimitsu
    Yokoi, Hiroyoshi
    Ando, Kenji
    Shirai, Shinichi
    Sakai, Koyu
    Kondo, Katsuhiro
    Iwabuchi, Masashi
    Nobuyoshi, Masakiyo
    CIRCULATION, 2011, 124 (21)
  • [9] Safety and Efficacy of Exercise Training After Coronary Stenting in Patients With Stable Coronary Artery Disease
    Soga, Yoshimitsu
    Yokoi, Hiroyoshi
    Amemiya, Kisaki
    Iwabuchi, Masashi
    Nobuyoshi, Masakiyo
    CIRCULATION JOURNAL, 2011, 75 (10) : 2379 - 2386
  • [10] Safety and efficacy of a novel calcified plaque modification technique - Shockwave Intravascular Lithotripsy - in patients with coronary artery disease: Mid-term outcomes
    Rola, Piotr
    Furtan, Lukasz
    Wlodarczak, Szymon
    Barycki, Mateusz
    Kedzierska, Michalina
    Doroszko, Adrian
    Wlodarczak, Adrian
    Lesiak, Maciej
    KARDIOLOGIA POLSKA, 2023, 81 (09) : 878 - 885