Representative-Based Cold Start for Adaptive SSVEP-BCI

被引:11
|
作者
Shi, Nanlin [1 ]
Li, Xiang [1 ]
Liu, Bingchuan [1 ]
Yang, Chen [2 ]
Wang, Yijun [3 ]
Gao, Xiaorong [1 ]
机构
[1] Tsinghua Univ, Sch Med, Dept Biomed Engn, Beijing 100084, Peoples R China
[2] Beijing Univ Posts & Telecommun, Sch Elect Engn, Beijing 100876, Peoples R China
[3] Chinese Acad Sci, Inst Semicond, State Key Lab Integrated Optoelect, Beijing 100083, Peoples R China
基金
中国国家自然科学基金;
关键词
Brain modeling; Data models; Adaptation models; Optimization; Transfer learning; Training; Standards; User dependent BCI; user independent BCI; cold start problem; adaptive BCI;
D O I
10.1109/TNSRE.2023.3245654
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective: The tradeoff between calibration effort and model performance still hinders the user experience for steady-state visual evoked brain-computer interfaces (SSVEP-BCI). To address this issue and improve model generalizability, this work investigated the adaptation from the cross-dataset model to avoid the training process, while maintaining high prediction ability. Methods: When a new subject enrolls, a group of user-independent (UI) models is recommended as the representative from a multi-source data pool. The representative model is then augmented with online adaptation and transfer learning techniques based on user-dependent (UD) data. The proposed method is validated on both offline (N=55) and online (N=12) experiments. Results: Compared with the UD adaptation, the recommended representative model relieved approximately 160 trials of calibration efforts for a new user. In the online experiment, the time window decreased from 2 s to 0.56 +/- 0.2 s, while maintaining high prediction accuracy of 0.89-0.96. Finally, the proposed method achieved the average information transfer rate (ITR) of 243.49 bits/min, which is the highest ITR ever reported in a complete calibration-free setting. The results of the offline result were consistent with the online experiment. Conclusion: Representatives can be recommended even in a cross-subject/device/session situation. With the help of represented UI data, the proposed method can achieve sustained high performance without a training process. Significance: This work provides an adaptive approach to the transferable model for SSVEP-BCIs, enabling a more generalized, plug-and-play and high-performance BCI free of calibrations.
引用
收藏
页码:1521 / 1531
页数:11
相关论文
共 50 条
  • [41] Towards in SSVEP-BCI Systems for Assistance in Decision-Making
    Hubner, Rodrigo
    Ruiz Aylon, Linnyer Beatryz
    Barreto, Gilmar
    PROCEEDINGS OF THE FUTURE TECHNOLOGIES CONFERENCE (FTC) 2018, VOL 1, 2019, 880 : 1 - 18
  • [42] Design of a Control Platform for Mobile Robot with SSVEP-BCI System
    Liu, Yang
    Li, Xinyang
    Yang, Chenguang
    PROCEEDINGS OF THE IEEE 2019 9TH INTERNATIONAL CONFERENCE ON CYBERNETICS AND INTELLIGENT SYSTEMS (CIS) ROBOTICS, AUTOMATION AND MECHATRONICS (RAM) (CIS & RAM 2019), 2019, : 198 - 203
  • [43] The Combination of CCA and PSDA Detection Methods in a SSVEP-BCI System
    Wang, Ruimin
    Wu, Wen
    Iramina, Keiji
    Ge, Sheng
    2014 11TH WORLD CONGRESS ON INTELLIGENT CONTROL AND AUTOMATION (WCICA), 2014, : 2424 - 2427
  • [44] Independent component analysis for a low-channel SSVEP-BCI
    Izabela Rejer
    Łukasz Cieszyński
    Pattern Analysis and Applications, 2019, 22 : 47 - 62
  • [45] An embedded lightweight SSVEP-BCI electric wheelchair with hybrid stimulator
    Na, Rui
    Hu, Chun
    Sun, Ying
    Wang, Shuai
    Zhang, Shuailei
    Han, Mingzhe
    Yin, Wenhan
    Zhang, Jun
    Chen, Xinlei
    Zheng, Dezhi
    DIGITAL SIGNAL PROCESSING, 2021, 116
  • [46] Assisted closed-loop optimization of SSVEP-BCI efficiency
    Fernandez-Vargas, Jacobo
    Pfaff, Hanns U.
    Rodriguez, Francisco B.
    Varona, Pablo
    FRONTIERS IN NEURAL CIRCUITS, 2013, 7
  • [47] Optimization of SSVEP-BCI Virtual Reality Stereo Stimulation Parameters Based on Knowledge Graph
    Zhu, Shixuan
    Yang, Jingcheng
    Ding, Peng
    Wang, Fan
    Gong, Anmin
    Fu, Yunfa
    BRAIN SCIENCES, 2023, 13 (05)
  • [48] Humanoid Robot Walking in Maze Controlled by SSVEP-BCI Based on Augmented Reality Stimulus
    Zhang, Shangen
    Gao, Xiaorong
    Chen, Xiaogang
    FRONTIERS IN HUMAN NEUROSCIENCE, 2022, 16
  • [49] A high-frequency SSVEP-BCI system based on a 360 Hz refresh rate
    Liu, Ke
    Yao, Zhaolin
    Zheng, Li
    Wei, Qingguo
    Pei, Weihua
    Gao, Xiaorong
    Wang, Yijun
    JOURNAL OF NEURAL ENGINEERING, 2023, 20 (04)
  • [50] Statistical evaluation of a novel SSVEP-BCI stimulation setup based on depth-of-field
    Cotrina, Anibal
    Benevides, Alessandro Botti
    Castillo-Garcia, Javier
    Ferreira, Andre
    Bastos Filho, Teodiano Freire
    Revista Brasileira de Engenharia Biomedica, 2015, 31 (04): : 295 - 306