Personalized colorectal cancer screening: study protocol of a mixed-methods study on the effectiveness of tailored intervals based on prior f-Hb concentration in a fit-based colorectal cancer screening program (PERFECT-FIT)

被引:10
|
作者
Breekveldt, Emilie C. H. [1 ,2 ]
Toes-Zoutendijk, Esther [1 ]
de Jonge, Lucie [1 ]
Spaander, Manon C. W. [3 ]
Dekker, Evelien [4 ]
van Kemenade, Folkert J. [5 ]
van Vuuren, Anneke J. [3 ]
Ramakers, Christian R. B. [6 ]
Nagtegaal, Iris D. [7 ]
van Leerdam, Monique E. [2 ,8 ]
Lansdorp-Vogelaar, Iris [1 ]
机构
[1] Erasmus MC Univ Med Ctr, Dept Publ Hlth, Dr Molewaterplein 40, NL-3015 GD Rotterdam, Netherlands
[2] Antoni Leeuwenhoek Hosp, Netherlands Canc Inst, Dept Gastroenterol & Hepatol, Amsterdam, Netherlands
[3] Univ Med Ctr Rotterdam, Erasmus MC, Dept Gastroenterol & Hepatol, Rotterdam, Netherlands
[4] Amsterdam Univ Med Ctr, Dept Gastroenterol & Hepatol, Locat AMC, Amsterdam, Netherlands
[5] Univ Med Ctr Rotterdam, Erasmus MC, Dept Pathol, Rotterdam, Netherlands
[6] Univ Med Ctr Rotterdam, Erasmus MC, Dept Clin Chem, Rotterdam, Netherlands
[7] Radboud Univ Nijmegen, Med Ctr, Dept Pathol, Nijmegen, Netherlands
[8] Leiden Univ, Med Ctr, Dept Gastroenterol & Hepatol, Leiden, Netherlands
关键词
Colorectal cancer; Colorectal neoplasia; Colonoscopy; Colorectal cancer screening; Fecal immunochemical testing; FECAL HEMOGLOBIN CONCENTRATION; RISK STRATIFICATION; NEOPLASIA; TESTS;
D O I
10.1186/s12876-023-02670-1
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background In 2014, the national population-based colorectal cancer (CRC) screening program was implemented in the Netherlands. Biennial fecal immunochemical testing (FIT) for hemoglobin (Hb) is used at a cut-off of 47 mu g Hb per gram feces. The CRC screening program successfully started, with high participation rates and yield of screening. Now that the program has reached a steady state, there is potential to further optimize the program. Previous studies showed that prior fecal Hb (f-Hb) concentrations just below the FIT cut-off are associated with a higher risk for detection of advanced neoplasia (AN) at subsequent screening rounds. We aim to achieve a better balance between the harms and benefits of CRC screening by offering participants tailored invitation intervals based on prior f-Hb concentrations after negative FIT. Methods This mixed-methods study will be performed within the Dutch national CRC screening program and will consist of: (1) a randomized controlled trial (RCT), (2) focus group studies, and (3) decision modelling. The primary outcome is the yield of AN per screened individual in personalized screening vs. uniform screening. Secondary outcomes are perspectives on, acceptability of and adherence to personalized screening, as well as long-term outcomes of personalized vs. uniform screening. The RCT will include 20,000 participants of the Dutch CRC screening program; 10,000 in the intervention and 10,000 in the control arm. The intervention arm will receive a personalized screening interval based on the prior f-Hb concentration (1, 2 or 3 years). The control arm will receive a screening interval according to current practice (2 years). The focus group studies are designed to understand individuals' perspectives on and acceptability of personalized CRC screening. Results of the RCT will be incorporated into the MISCAN-Colon model to determine long-term benefits, harms, and costs of personalized vs. uniform CRC screening. Discussion The aim of this study is to evaluate the yield, feasibility, acceptability and (cost-) effectiveness of personalized CRC screening through tailored invitation intervals based on prior f-Hb concentrations. This knowledge may be of guidance for health policy makers and may provide evidence for implementing personalized CRC screening in The Netherlands and/or other countries using FIT as screening modality.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] OPTIMAL CUT-OFF VALUE IN A FIT-BASED COLORECTAL CANCER-SCREENING PROGRAM: A PROSPECTIVE STUDY IN A MEXICAN POPULATION
    Jimenez, Beatriz Sanchez
    Torrecilla, Wilmer
    Guerrero, Angelica I. Hernandez
    Del Monte, Julio Sanchez
    Macias, Jorge Perez
    Castellon, Genoveva Salgado
    GASTROINTESTINAL ENDOSCOPY, 2023, 97 (06) : AB475 - AB475
  • [22] EFFECT OF COLONOSCOPY HISTORY ON OUTCOMES OF FIT-BASED COLORECTAL CANCER SCREENING: A DANISH POPULATION-BASED COHORT STUDY
    Birindwa, Guilian
    Wheler, Jannik H.
    Troelsen, Frederikke Schonfeldt
    Thomsen, Mette K.
    Erichsen, Rune
    Bretthauer, Michael
    Sorensen, Henrik Toft
    GASTROENTEROLOGY, 2024, 166 (05) : S45 - S45
  • [23] Interval Cancers in a Colorectal Cancer Population Screening Fit-Based: Result of Two Rounds
    Crotta, Sergio
    Paganin, Simona
    Dagnes, Bruna
    Lolli, Roberto
    GASTROENTEROLOGY, 2012, 142 (05) : S513 - S513
  • [24] Second-Look Colonoscopies and the Impact on Capacity in FIT-Based Colorectal Cancer Screening
    Grobbee, Esmee J.
    Kapidzic, Atija
    van Vuuren, Anneke J.
    van Leerdam, Monique
    Lansdorp-Vogelaar, Iris
    Looman, Caspar W. N.
    Bruno, Marco J.
    Kuipers, Ernst J.
    Spaander, Manon C. W.
    AMERICAN JOURNAL OF GASTROENTEROLOGY, 2015, 110 (07): : 1072 - 1077
  • [25] Optimizing Screening Programs by Real-Time Monitoring: Outcomes of the National Colorectal Cancer FIT-Based Screening Program of the Netherlands
    Toes-Zoutendijk, Esther
    van Leerdam, Monique
    Dekker, Evelien
    van Hees, Frank
    van Kemenade, Folkert
    van der Meulen, Miriam P.
    van Vuuren, Anneke
    Kuipers, Ernst J.
    Bonfrer, Johannes M. G.
    Biermann, Katharina
    Thomeer, Maarten
    van Veldhuizen, Harriet
    de Koning, Harry
    Spaander, Manon
    Lansdorp-Vogelaar, Iris
    GASTROENTEROLOGY, 2016, 150 (04) : S757 - S758
  • [26] ADENOMA DETECTION RATE IS NOT ASSOCIATED WITH COLORECTAL CANCER INCIDENCE AND MORTALITY IN AN ORGANISED FIT-BASED CRC SCREENING PROGRAM
    Antonelli, G.
    Battagello, J.
    Zorzi, M.
    Hassan, C.
    DIGESTIVE AND LIVER DISEASE, 2021, 53 : S100 - S100
  • [27] First local results of the Finnish FIT-based colorectal cancer screening program - high yield, low complications
    Relander, Pyry
    Rauhaniemi, Elli
    Loyttyniemi, Eliisa
    Salminen, Kimmo
    Carpelan, Anu
    Koffert, Jukka
    SCANDINAVIAN JOURNAL OF GASTROENTEROLOGY, 2025, 60 (03) : 219 - 224
  • [28] INTERVAL CANCERS IN A COLORECTAL CANCER POPULATION SCREENING FIT-BASED: PRELIMINARY RESULT OF THREE EXAMINATIONS
    Crotta, S.
    Senore, C.
    Paganin, S.
    Lolli, R.
    Cerrato, C.
    Dagnes, B.
    DIGESTIVE AND LIVER DISEASE, 2014, 46 : S21 - S21
  • [29] Participation, yield, and interval carcinomas in three rounds of biennial FIT-based colorectal cancer screening
    Stegeman, I.
    van Doorn, S. C.
    Mundt, M. W.
    Mallant-Hent, R. C.
    Bongers, E.
    Elferink, M. A. G.
    Fockens, P.
    Stroobants, A. K.
    Bossuyt, P. M.
    Dekker, E.
    CANCER EPIDEMIOLOGY, 2015, 39 (03) : 388 - 393
  • [30] Nationwide participation in FIT-based colorectal cancer screening in Denmark during the COVID-19 pandemic: An observational study
    Olesen, Tina Bech
    Jensen, Henry
    Moller, Henrik
    Jensen, Jens Winther
    Andersen, Berit
    Rasmussen, Morten
    ELIFE, 2023, 12