Personalized colorectal cancer screening: study protocol of a mixed-methods study on the effectiveness of tailored intervals based on prior f-Hb concentration in a fit-based colorectal cancer screening program (PERFECT-FIT)

被引:10
|
作者
Breekveldt, Emilie C. H. [1 ,2 ]
Toes-Zoutendijk, Esther [1 ]
de Jonge, Lucie [1 ]
Spaander, Manon C. W. [3 ]
Dekker, Evelien [4 ]
van Kemenade, Folkert J. [5 ]
van Vuuren, Anneke J. [3 ]
Ramakers, Christian R. B. [6 ]
Nagtegaal, Iris D. [7 ]
van Leerdam, Monique E. [2 ,8 ]
Lansdorp-Vogelaar, Iris [1 ]
机构
[1] Erasmus MC Univ Med Ctr, Dept Publ Hlth, Dr Molewaterplein 40, NL-3015 GD Rotterdam, Netherlands
[2] Antoni Leeuwenhoek Hosp, Netherlands Canc Inst, Dept Gastroenterol & Hepatol, Amsterdam, Netherlands
[3] Univ Med Ctr Rotterdam, Erasmus MC, Dept Gastroenterol & Hepatol, Rotterdam, Netherlands
[4] Amsterdam Univ Med Ctr, Dept Gastroenterol & Hepatol, Locat AMC, Amsterdam, Netherlands
[5] Univ Med Ctr Rotterdam, Erasmus MC, Dept Pathol, Rotterdam, Netherlands
[6] Univ Med Ctr Rotterdam, Erasmus MC, Dept Clin Chem, Rotterdam, Netherlands
[7] Radboud Univ Nijmegen, Med Ctr, Dept Pathol, Nijmegen, Netherlands
[8] Leiden Univ, Med Ctr, Dept Gastroenterol & Hepatol, Leiden, Netherlands
关键词
Colorectal cancer; Colorectal neoplasia; Colonoscopy; Colorectal cancer screening; Fecal immunochemical testing; FECAL HEMOGLOBIN CONCENTRATION; RISK STRATIFICATION; NEOPLASIA; TESTS;
D O I
10.1186/s12876-023-02670-1
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background In 2014, the national population-based colorectal cancer (CRC) screening program was implemented in the Netherlands. Biennial fecal immunochemical testing (FIT) for hemoglobin (Hb) is used at a cut-off of 47 mu g Hb per gram feces. The CRC screening program successfully started, with high participation rates and yield of screening. Now that the program has reached a steady state, there is potential to further optimize the program. Previous studies showed that prior fecal Hb (f-Hb) concentrations just below the FIT cut-off are associated with a higher risk for detection of advanced neoplasia (AN) at subsequent screening rounds. We aim to achieve a better balance between the harms and benefits of CRC screening by offering participants tailored invitation intervals based on prior f-Hb concentrations after negative FIT. Methods This mixed-methods study will be performed within the Dutch national CRC screening program and will consist of: (1) a randomized controlled trial (RCT), (2) focus group studies, and (3) decision modelling. The primary outcome is the yield of AN per screened individual in personalized screening vs. uniform screening. Secondary outcomes are perspectives on, acceptability of and adherence to personalized screening, as well as long-term outcomes of personalized vs. uniform screening. The RCT will include 20,000 participants of the Dutch CRC screening program; 10,000 in the intervention and 10,000 in the control arm. The intervention arm will receive a personalized screening interval based on the prior f-Hb concentration (1, 2 or 3 years). The control arm will receive a screening interval according to current practice (2 years). The focus group studies are designed to understand individuals' perspectives on and acceptability of personalized CRC screening. Results of the RCT will be incorporated into the MISCAN-Colon model to determine long-term benefits, harms, and costs of personalized vs. uniform CRC screening. Discussion The aim of this study is to evaluate the yield, feasibility, acceptability and (cost-) effectiveness of personalized CRC screening through tailored invitation intervals based on prior f-Hb concentrations. This knowledge may be of guidance for health policy makers and may provide evidence for implementing personalized CRC screening in The Netherlands and/or other countries using FIT as screening modality.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Personalized colorectal cancer screening: study protocol of a mixed-methods study on the effectiveness of tailored intervals based on prior f-Hb concentration in a fit-based colorectal cancer screening program (PERFECT-FIT)
    Emilie C. H. Breekveldt
    Esther Toes-Zoutendijk
    Lucie de Jonge
    Manon C. W. Spaander
    Evelien Dekker
    Folkert J. van Kemenade
    Anneke J. van Vuuren
    Christian R. B. Ramakers
    Iris D. Nagtegaal
    Monique E. van Leerdam
    Iris Lansdorp-Vogelaar
    BMC Gastroenterology, 23
  • [2] Quality Monitoring of a FIT-Based Colorectal Cancer Screening Program
    Toes-Zoutendijk, Esther
    Bonfrer, Johannes M. G.
    Ramakers, Christian
    Thelen, Marc
    Spaander, Manon C. W.
    Dekker, Evelien
    van der Meulen, Miriam P.
    Buskermolen, Maaike
    van Vuuren, Anneke J.
    Kuipers, Ernst J.
    van Kemenade, Folkert J.
    van Velthuysen, Marie-Louise F.
    Thomeer, Maarten G. J.
    van Veldhuizen, Harriet
    van Ballegooijen, Marjolein
    de Koning, Harry J.
    van Leerdam, Monique E.
    Lansdorp-Vogelaar, Iris
    CLINICAL CHEMISTRY, 2019, 65 (03) : 419 - 426
  • [3] COMPARISON OF FIT-BASED COLORECTAL CANCER SCREENING PROGRAMS
    Toes-Zoutendijk, Esther
    Portillo, Isabel
    Hoeck, Sarah
    Opstal-van Winden, Annemieke
    Peterse, Elisabeth F.
    Perrin, Philippe
    Dubois, Catherine
    Osoro, Caroline
    Lansdorp-Vogelaar, Iris
    Bardou, Marc
    GASTROENTEROLOGY, 2018, 154 (06) : S570 - S570
  • [4] Results of the FIT-based National Colorectal Cancer Screening Program in Slovenia
    Tepes, Bojan
    Bracko, Matej
    Mlakar, Dominika Novak
    Stefanovic, Milan
    Stabuc, Borut
    Grazio, Snjezana Frkovic
    Zakotnik, Jozica Maucec
    JOURNAL OF CLINICAL GASTROENTEROLOGY, 2017, 51 (06) : E52 - E59
  • [5] POST-COLONOSCOPY MORTALITY IN A FIT-BASED COLORECTAL CANCER SCREENING PROGRAM
    Kooyker, Arthur I.
    Toes-Zoutendijk, Esther
    Opstal-van Winden, Annemieke
    Spaander, Manon
    Dekker, Evelien
    Buskermolen, Maaike
    van Vuuren, Anneke
    Kuipers, Ernst J.
    van Kemenade, Folkert J.
    van Veldhuizen, Harriet
    Thomeer, Maarten G.
    Nagtegaal, Iris D.
    Ramakers, Christian
    van Ballegooijen, Marjolein
    De Koning, Harry
    Lansdorp-Vogelaar, Iris
    van Leerdam, Monique
    GASTROENTEROLOGY, 2019, 156 (06) : S20 - S20
  • [6] COLONOSCOPY QUALITY ASSURANCE IN AN ORGANIZED FIT-BASED COLORECTAL CANCER SCREENING PROGRAM
    Spaander, Manon
    Wisse, Pieter
    der Boer, S. Y.
    den Hartog, B.
    Pool, M. Oudkerk
    Droste, Jochim S. Terhaar Sive
    Verveer, C.
    van Maaren-Meijer, Frejanne G.
    Dekker, Evelien
    GASTROINTESTINAL ENDOSCOPY, 2020, 91 (06) : AB463 - AB464
  • [7] Positive Predictive Value Increases With Age in a FIT-Based Colorectal Cancer Screening Program
    Wieten, Els
    Grobbee, Elisabeth J.
    Hansen, Bettina E.
    Bruno, Marco J.
    Kuipers, Ernst J.
    Lansdorp-Vogelaar, Iris
    Spaander, Manon C.
    GASTROENTEROLOGY, 2015, 148 (04) : S760 - S760
  • [8] The performance indicator of colonic intubation (PICI) in a FIT-based colorectal cancer screening program
    Lund, Martin
    Erichsen, Rune
    Njor, Sisse Helle
    Laurberg, Soren
    Valori, Roland
    Andersen, Berit
    Ljungmann, Ken
    Kannerup, Anne-Sofie
    Madsen, Gunnar
    Jensen, Thomas Moller
    Nielsen, Knud Thygesen
    Lyhne, Soren
    Jepsen, Mogens Harrits
    Pahle, Einar
    Thode, Dorrit
    SCANDINAVIAN JOURNAL OF GASTROENTEROLOGY, 2019, 54 (09) : 1176 - 1181
  • [9] The optimal cut-off value in fit-based colorectal cancer screening: An observational study
    Njor, Sisse Helle
    Andersen, Berit
    Friis-Hansen, Lennart
    de Haas, Niels
    Linnemann, Dorte
    Norgaard, Henrik
    Roikjaer, Ole
    Sondergaard, Bo
    Rasmussen, Morten
    CANCER MEDICINE, 2021, 10 (05): : 1872 - 1879
  • [10] Effect of a FIT-Based Colorectal Cancer Screening Program on Mortality Estimated by the Regression Discontinuity Design
    Thomsen, Mette K.
    Nicolaisen, Sia K.
    Pedersen, Lars
    Lash, Timothy L.
    Erichsen, Rune
    Sorensen, Henrik Toft
    Mikkelsen, Ellen M.
    AMERICAN JOURNAL OF EPIDEMIOLOGY, 2023, 192 (09) : 1475 - 1484