Numerical investigation on two-phase oscillating flow and heat transfer enhancement for a cooling channel with ribs

被引:7
|
作者
Xie, Guangyi [1 ]
Lei, Jilin [1 ,2 ]
Deng, Xiwen [1 ,2 ]
Wang, Jinkun [1 ]
Chen, Hao [1 ]
机构
[1] Kunming Univ Sci & Technol, Yunnan Key Lab Internal Combust Engines, Kunming 650500, Peoples R China
[2] Kunming Yunnei Power Co Ltd, Yunnan Key Lab Plateau Emiss Internal Combust Engi, Kunming 650200, Peoples R China
基金
中国国家自然科学基金;
关键词
Two-phase oscillating flow; Heat transfer; Cooling channel; Rib structure; Numerical investigation; GALLERY; SURFACE; OIL; PERFORMANCE; NANOFLUIDS; SIMULATION; MODEL;
D O I
10.1016/j.ijthermalsci.2023.108191
中图分类号
O414.1 [热力学];
学科分类号
摘要
Rib structures can enhance heat transfer in single-phase flows. In order to investigate the influence of semi-circular rib structures on the two-phase oscillating flow and heat transfer characteristics, two-dimensional computational fluid dynamics (CFD) models were established for the cooling channels with rib diameters of 2, 4, 6, and 8 mm. The shear stress transportation (SST) k-omega turbulence model and the Volume of Fluid (VOF) symbolscript-Set model were used to simulate the flow pattern and predict the two-phase flow interface. A visual experiment was performed to validate the CFD models. The results showed that during the reciprocating motion of the channel, both sides of the rib were impinged and flushed continuously by the cooling oil. Therefore, the heat transfer on the both sides of the rib was enhanced, and the peak value of the heat transfer coefficient (HTC) increased by 100.5% when the rib diameter was 2 mm compared to the channel without ribs. The rib diameter increase had little influence on the peak value of the cycle-average HTC near the rib and the left wall. However, the oil flow velocity on the flat wall and the impingement intensity on the top wall were weakened due to the rib structure, resulting in a reduction in the cycle-average HTCs of the flat wall and the top wall. Furthermore, the larger the rib diameter, the more reduction in the cycle-average HTCs of the flat wall and the top wall. When the rib diameter was 8 mm, the reductions in the cycle-average HTCs on the flat wall and the top wall were the most obvious, reaching 10.7% and 8.3%, respectively. The numerical results in this study can provide design guidance for heat transfer enhancement of cooling channels during reciprocating motions.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Numerical investigation of heat transfer enhancement of graphene nanofluid in turbulent flow conditions using the Lagrangian two-phase model
    Fujimoto, Kotaro
    Shibata, Aima
    Torii, Shuichi
    MATERIALS TODAY-PROCEEDINGS, 2022, 66 : 1591 - 1597
  • [22] Two-phase magnetohydrodynamic flow and heat transfer in an inclined channel
    Malashetty, MS
    Umavathi, JC
    INTERNATIONAL JOURNAL OF MULTIPHASE FLOW, 1997, 23 (03) : 545 - 560
  • [23] Heat transfer enhancement by mist/air two-phase flow in a high-temperature channel
    Cao, Junxian
    Ye, Mengqi
    Li, Haiwang
    Wang, Tianyou
    Che, Zhizhao
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2022, 193
  • [24] Heat transfer enhancement by mist/air two-phase flow in a high-temperature channel
    Cao, Junxian
    Ye, Mengqi
    Li, Haiwang
    Wang, Tianyou
    Che, Zhizhao
    International Journal of Heat and Mass Transfer, 2022, 193
  • [25] Study on the effect of inclination angle on two-phase oscillating flow and heat transfer characteristics of piston cooling galleries
    Xie, Guangyi
    Lei, Jilin
    Deng, Xiwen
    Jia, Dewen
    Deng, Wei
    Jiang, Xiangsen
    Wen, Jun
    CASE STUDIES IN THERMAL ENGINEERING, 2022, 38
  • [26] Numerical study of heat transfer enhancement in a channel flow using an oscillating vortex generator
    Yang, SJ
    HEAT AND MASS TRANSFER, 2003, 39 (03) : 257 - 265
  • [27] Experimental investigation on hydrodynamics and heat transfer of fluid flow into channel for cooling of rectangular ribs by passive and EHD active enhancement methods
    Alamghohlou, A.
    Esmaeilzadeh, E.
    EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2012, 38 : 61 - 73
  • [28] Numerical study of heat transfer enhancement in a channel flow using an oscillating vortex generator
    S.-J. Yang
    Heat and Mass Transfer, 2003, 39 : 257 - 265
  • [29] Effect of spray cooling on heat transfer in a two-phase helium flow
    Perraud, S.
    Puech, L.
    Thibault, P.
    Rousset, B.
    Wolf, P. E.
    CRYOGENICS, 2013, 57 : 74 - 87
  • [30] NUMERICAL INVESTIGATION OF TWO PHASE FLOW AND HEAT TRANSFER CHARACTERISTICS OF PASSIVE CONTAINMENT COOLING SYSTEM
    Deng, Jia-Jia
    Pan, Liang-Ming
    Kang, Mei-Qiang
    PROCEEDINGS OF THE 21ST INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING - 2013, VOL 3, 2014,