Nonenhanced Photon Counting CT of the Head Impact of the keV Level, Iterative Reconstruction and Calvaria on Image Quality in Monoenergetic Images

被引:4
|
作者
Michael, Arwed Elias [1 ,3 ]
Schoenbeck, Denise [1 ]
Woeltjen, Matthias Michael [1 ]
Boriesosdick, Jan [1 ]
Kroeger, Jan Robert [1 ]
Moenninghoff, Christoph [1 ]
Horstmeier, Sebastian [1 ]
Niehoff, Julius Henning [1 ]
Kabbasch, Christoph [2 ]
Goertz, Lukas [2 ]
Borggrefe, Jan [1 ]
机构
[1] Ruhr Univ Bochum, Johannes Wesling Univ Hosp, Dept Radiol Neuroradiol & Nucl Med, Bochum, Germany
[2] Univ Hosp Cologne, Dept Radiol & Neuroradiol, Cologne, Germany
[3] Johannes Wesling Univ Hosp Muehlenkreiskliniken Ao, Hans Nolte Str 1, D-32429 Minden, Germany
关键词
Computed tomography; Photon counting detector; Nonenhanced CT of the head; Virtual monoenergetic images; Iterative reconstruction; Quantum iterative reconstruction; DETECTOR CT; REDUCTION; ARTIFACTS;
D O I
10.1007/s00062-023-01331-w
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
PurposeNonenhanced computed tomography (CT) of the head is among the most commonly performed CT examinations. The spectral information acquired by photon counting CT (PCCT) allows generation of virtual monoenergetic images (VMI). At the same time, image noise can be reduced using quantum iterative reconstruction (QIR). In this study, the image quality of VMI was evaluated depending on the keV level and the QIR level. Furthermore, the influence of the cranial calvaria was investigated to determine the optimal reconstruction for clinical application.MethodsA total of 51 PCCT (NAEOTOM Alpha, Siemens Healthineers, Erlangen, Germany) of the head were retrospectively analyzed. In a quantitative analysis, gray and white matter ROIs were evaluated in different brain areas at all available keV levels and QIR levels with respect to signal, noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR). The distance to the cranial calvaria of the ROIs was included in the analysis. This was followed by a qualitative reading by five radiologists including experienced neuroradiologists.ResultsIn most ROIs, signal and noise varied significantly between keV levels (p < 0.0001). The CNR had a focal maximum at 66 keV and an absolute maximum at higher keV, slightly differently located depending on ROI and QIR level. With increasing QIR level, a significant reduction in noise was achieved (p < 0.0001) except just beneath the cranial calvaria. The cranial calvaria had a strong effect on the signal (p < 0.0001) but not on gray and white matter noise. In the qualitative reading, the 60 keV VMI was rated best.ConclusionIn nonenhanced PCCT of the head the selected keV level of the VMI and the QIR level have a crucial influence on image quality in VMI. The 60 keV and 66 keV VMI with high QIR level provided optimal subjective and objective image quality for clinical use. The cranial calvaria has a significant influence on the visualization of the adjacent brain matter; currently, this substantially limits the use of low keV VMIs (< 60 keV).
引用
收藏
页码:75 / 83
页数:9
相关论文
共 50 条
  • [21] Image-Quality Assessment of Polyenergetic and Virtual Monoenergetic Reconstructions of Unenhanced CT Scans of the Head: Initial Experiences with the First Photon-Counting CT Approved for Clinical Use
    Michael, Arwed Elias
    Boriesosdick, Jan
    Schoenbeck, Denise
    Woeltjen, Matthias Michael
    Saeed, Saher
    Kroeger, Jan Robert
    Horstmeier, Sebastian
    Lennartz, Simon
    Borggrefe, Jan
    Niehoff, Julius Henning
    DIAGNOSTICS, 2022, 12 (02)
  • [22] The impact of iterative reconstruction on image quality and radiation dose in thoracic and abdominal CT
    Kalmar, Peter I.
    Quehenberger, Franz
    Steiner, Juergen
    Lutfi, Andre
    Bohlsen, Dennis
    Talakic, Emina
    Hassler, Eva Maria
    Schoellnast, Helmut
    EUROPEAN JOURNAL OF RADIOLOGY, 2014, 83 (08) : 1416 - 1420
  • [23] Improved Discriminability of Severe Lung Injury and Atelectasis in Thoracic Trauma at Low keV Virtual Monoenergetic Images from Photon-Counting Detector CT
    Kaatsch, Hanns Leonhard
    Voellmecke, Maximilian Franz
    Becker, Benjamin V.
    Dillinger, Daniel
    Kubitscheck, Laura
    Woehler, Aliona
    Schaaf, Sebastian
    Piechotka, Joel
    Schreyer, Christof
    Schwab, Robert
    Overhoff, Daniel
    Waldeck, Stephan
    DIAGNOSTICS, 2024, 14 (19)
  • [24] Quantum Iterative Reconstruction for Abdominal Photon-counting Detector CT Improves Image Quality (Feb, 10.1148/radiol.211931, 2022)
    Sartoretti, Thomas
    Landsmann, Anna
    Nakhostin, Dominik
    Eberhard, Matthias
    Roeren, Christian
    Mergen, Victor
    Higashigaito, Kai
    Raupach, Rainer
    Alkadhi, Hatem
    Euler, Andre
    RADIOLOGY, 2022, 304 (03) : E55 - E55
  • [25] Photon Counting Detector CT-Based Virtual Noniodine Reconstruction Algorithm for In Vitro and In Vivo Coronary Artery Calcium Scoring: Impact of Virtual Monoenergetic and Quantum Iterative Reconstructions
    Fink, Nicola
    Zsarnoczay, Emese
    Schoepf, U. Joseph
    Griffith III, Joseph P. P.
    Wolf, Elias V.
    O'Doherty, Jim
    Suranyi, Pal
    Baruah, Dhiraj
    Kabakus, Ismail M.
    Ricke, Jens
    Varga-Szemes, Akos
    Emrich, Tilman
    INVESTIGATIVE RADIOLOGY, 2023, 58 (09) : 673 - 680
  • [26] Impact of iterative reconstruction on image quality of low-dose CT of the lumbar spine
    Alshamari, Muhammed
    Geijer, Mats
    Norrman, Eva
    Liden, Mats
    Krauss, Wolfgang
    Jendeberg, Johan
    Magnuson, Anders
    Geijer, Hakan
    ACTA RADIOLOGICA, 2017, 58 (06) : 702 - 709
  • [27] Application of machine-learning models to improve the image quality of photon-counting CT images
    Toyoda, T.
    Sato, S.
    Kiji, H.
    Kataoka, J.
    Kotoku, J.
    Taki, M.
    JOURNAL OF INSTRUMENTATION, 2021, 16 (05)
  • [28] Statistical Iterative Material Image Reconstruction with Patch based Enhanced 3DTV Regularization for Photon Counting CT
    Li, Danyang
    Li, Sui
    Zeng, Dong
    Bian, Zhaoying
    Ma, Jianhua
    15TH INTERNATIONAL MEETING ON FULLY THREE-DIMENSIONAL IMAGE RECONSTRUCTION IN RADIOLOGY AND NUCLEAR MEDICINE, 2019, 11072
  • [29] Ultra-high resolution coronary CT angiography on photon-counting detector CT: bi-centre study on the impact of quantum iterative reconstruction on image quality and accuracy of stenosis measurements
    Vecsey-Nagy, Milan
    Varga-Szemes, Akos
    Schoepf, U. Joseph
    Tremamunno, Giuseppe
    Fink, Nicola
    Zsarnoczay, Emese
    Szilveszte, Balint
    Graafen, Dirk
    Halfmann, Moritz C.
    Vattay, Borbala
    Boussoussou, Melinda
    O'Doherty, Jim
    Suranyi, Pal Spruill
    Maurovich-Horvat, Pal
    Emrich, Tilman
    EUROPEAN JOURNAL OF RADIOLOGY, 2024, 176
  • [30] The influence of iterative reconstruction level on image quality and radiation dose in CT pulmonary angiography examinations
    Harun, H.H.
    Karim, M.K.A.
    Abbas, Z.
    Sabarudin, A.
    Muniandy, S.C.
    Razak, H.R.A.
    Ng, K.H.
    Radiation Physics and Chemistry, 2021, 178