In the emergency department, the diameter of the inferior vena cava and aorta with ultrasonography in upper gi bleeding

被引:0
|
作者
Deniz, Muhammed Saltuk [1 ]
Tanriverdi, Fatih [2 ]
Yildirim, Cagdas [2 ]
Gunaydin, Gul Pamukcu [2 ]
Ergin, Mehmet [2 ]
Gok, Alper [1 ]
Kivrakoglu, Fatih [3 ]
Ersoy, Osman [4 ]
机构
[1] Ankara Res & Training Hosp, Dept Emergency Med, Ankara, Turkiye
[2] Ankara Yildirim Beyazit Univ, Fac Med, Dept Emergency Med, Ankara, Turkiye
[3] Osmaniye State Hosp, Dept Internal Med, Osmaniye, Turkiye
[4] Ankara Yildirim Beyazit Univ, Fac Med, Dept Internal Med, Ankara, Turkiye
来源
关键词
Gastrointestinal Bleeding; VCI Diameter; Aortic Diameter; USG;
D O I
10.4328/ACAM.21405
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aim: It was aimed to to investigate the use of USG imaging of the inferior vena cava (vci) and aortic diameter in predicting hospitalization in patients diagnosed with upper gi bleeding. Material And Methods: Forty-five patients over the age of 18 with upper gi bleeding who applied to the emergency department between 01/02/2019 and 01/10/2019, and 45 volunteers without hypovolemia as the control group were included in the study. VCI and aortic diameters of the patients were recorded prospectively using USG. Results: While the mean age in the patient group was 67 +/- 19 years, it was calculated as 74 +/- 9 years for the control group. The mean values of VCI expiratory, inspiratory diameters and VCI collapse index in the control group and patient group were respectively 18.47 +/- 2.5 mm, 15.2 +/- 2.4 mm and 0.18 +/- 0.06; 15.56 +/- 3.6 mm, 13.2 +/- 3 mm and 0.15-0.12. The mean values of aortic suprarenal and infrarenal diameters in the control group and patient group were respectively 24.3 +/- 2.2 mm and 21.7 +/- 2.3 mm; 19.0 +/- 3.6 mm, 17.0 +/- 3.4 mm. When all these parameters were compared with the control group, statistically significantly lower values were recorded in the patient group (p<0.001). Discussion: In our study, vci diameter, aortic diameter, and vci collapsibility index values were lower in patients with upper gi bleeding, and although they can be used as an aid in the diagnosis of the disease in the emergency department, these low values were not found to be associated with the hospitalization or discharge decision of the patients.
引用
收藏
页码:35 / 39
页数:5
相关论文
共 50 条
  • [31] Duplication of the inferior vena cava with a bridge over the infrarenal aorta
    Novo Martinez, Gloria Maria
    Ballesteros Pomar, Marta
    Alonso Argueeso, Gonzalo
    Zorita Calvo, Andres Manuel
    CIRUGIA ESPANOLA, 2015, 93 (04): : E23 - E23
  • [32] Disseminated embolization of an inferior vena cava filter with penetration of the aorta
    Brugger, Marcus
    Gaa, Jochen
    Bergmann, Katharina
    EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2024, 25 (10) : e253 - e253
  • [33] Value of inferior vena cava diameter and inferior vena cava collapse index in the evaluation of peripartum volume: A prospective cohort study
    Chong, Yiwen
    Yu, Yang
    Zhao, Yangyu
    Zhang, Yan
    EUROPEAN JOURNAL OF OBSTETRICS & GYNECOLOGY AND REPRODUCTIVE BIOLOGY, 2023, 285 : 69 - 73
  • [34] Emergency interruption of the inferior vena cava: a debatable issue
    Ricco, JB
    Bouin-Pineau, MH
    Camiade, C
    Blecha, LM
    Reynaud, P
    Faroy, F
    Marchand, C
    CARDIOVASCULAR SURGERY, 2000, 8 (06): : 411 - 421
  • [35] Measurement of vena cava inferior diameter in hemorrhagic shock diagnosis
    DR Akıllı
    A Bayır
    MD Cander
    DR Kara
    Critical Care, 12 (Suppl 2):
  • [36] Inferior vena cava ultrasonography in the assessment of intravascular volume status and fluid responsiveness in the emergency department and intensive care unit: A critical analysis review
    Spiliotaki, Eleni
    Saranteas, Theodosios
    Moschovaki, Nefeli
    Panagouli, Konstantina
    Pistioli, Efstathia
    Kitsinelis, Vasilios
    Briasoulis, Panagiotis
    Papadimos, Thomas
    JOURNAL OF CLINICAL ULTRASOUND, 2022, 50 (05) : 733 - 744
  • [37] Usefulness of ultrasonography of inferior vena cava and bioelectrical impedance against NT-proBNP for the diagnosis of acute descompensated heart failure in an emergency department
    Jose Curbelo, J.
    Gil, P.
    Mesado, D.
    Cadinanos, J.
    EUROPEAN JOURNAL OF HEART FAILURE, 2015, 17 : 8 - 8
  • [38] Inferior Vena Cava Diameter as a Predictor of Mortality in Septic Shock
    Yasser, Muhammad
    Mawri, Alsafadi Sagger
    Shah, Jainil
    Jain, Tarun
    Dirani, George
    Nakhle, Asaad
    Abdelrahim, Elsheikh
    Michaels, Alexander
    Huda, Najia
    Ananthasubramaniam, Karthik
    CHEST, 2016, 150 (04) : 366A - 366A
  • [39] Correlation of the Inferior Vena Cava Diameter With the Central Venous Pressure
    Arthur, Mary E.
    Castresana, Manuel R.
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2008, 22 (06) : 942 - 942
  • [40] PRESSURE-DIAMETER RELATIONSHIP FOR THE INFERIOR VENA-CAVA
    KOYANAGI, S
    IMAIZUMI, T
    YAMAMOTO, K
    TAKESHITA, A
    CIRCULATION, 1986, 74 (04) : 454 - 454