The use of intraoperative technology (IT), such as computer-assisted navigation (CAN) and robot-assisted surgery (RA), in total knee arthroplasty (TKA) is increasingly popular due to its ability to enhance surgical precision and reduce radiographic outliers. There is disputing evidence as to whether IT leads to better clinical outcomes and reduced postoperative pain. The purpose of this study was to determine if use of CAN or RA in TKA improves pain outcomes. This is a retrospective review of a multicenter randomized control trial of 327 primary TKAs. Demographics, surgical time, IT use (CAN/RA), length of stay (LOS), and opioid consumption (in morphine milligram equivalents) were collected. Analysis was done by comparing IT ( n =110) to a conventional TKA cohort ( n =217). When accounting for demographic differences and the use of a tourniquet, the IT cohort had shorter surgical time (88.77 +/- 18.57 vs. 98.12 +/- 22.53minutes; p =0.005). While postoperative day 1 pain scores were similar ( p =0.316), the IT cohort has less opioid consumption at 2 weeks ( p =0.006) and 1 month ( p =0.005) postoperatively, but not at 3 months ( p =0.058). When comparing different types of IT, CAN, and RA, we found that they had similar surgical times ( p =0.610) and pain scores ( p =0.813). Both cohorts had similar opioid consumption at 2 weeks ( p =0.092), 1 month ( p =0.058), and 3 months ( p =0.064) postoperatively. The use of IT in TKA does not yield a clinically significant reduction in pain outcomes. There was also no difference in pain or perioperative outcomes between CAN and RA technology used in TKA.
引用
收藏
页码:439 / 444
页数:6
相关论文
共 50 条
  • [21] Robotic-assisted technology does not influence functional outcomes among obese and morbidly obese total knee arthroplasty patients
    Brian P. McCormick
    Sarah Trent
    Xue Geng
    Ji Won Lee
    Henry R. Boucher
    Journal of Experimental Orthopaedics, 10
  • [22] Robotic-assisted technology does not influence functional outcomes among obese and morbidly obese total knee arthroplasty patients
    McCormick, Brian P. P.
    Trent, Sarah
    Geng, Xue
    Lee, Ji Won
    Boucher, Henry R. R.
    JOURNAL OF EXPERIMENTAL ORTHOPAEDICS, 2023, 10 (01)
  • [23] Individualized Functional Knee Alignment in Total Knee Arthroplasty: A Robotic-assisted Technique
    Clark, Gavin W.
    Esposito, Christina, I
    Wood, David
    TECHNIQUES IN ORTHOPAEDICS, 2022, 37 (03) : 185 - 191
  • [24] Robotic-assisted Unicompartmental Knee Arthroplasty
    Tamam, Cuneyt
    Poehling, Gary G.
    SPORTS MEDICINE AND ARTHROSCOPY REVIEW, 2014, 22 (04): : 219 - 222
  • [25] Does computer-assisted surgical navigation total knee arthroplasty reduce venous thromboembolism compared with conventional total knee arthroplasty?
    Ooi, L. H.
    Lo, N. N.
    Yeo, S. J.
    Ong, B. C.
    Ding, Z. P.
    Lefi, A.
    SINGAPORE MEDICAL JOURNAL, 2008, 49 (08) : 610 - 614
  • [26] Aetiology of patient dissatisfaction following primary total knee arthroplasty in the era of robotic-assisted technology
    Gardner, J.
    Roman, E. R.
    Bhimani, R.
    Mashni, S. J.
    Whitaker, J. E.
    Smith, L. S.
    Swiergosz, A.
    Malkani, A. L.
    BONE & JOINT OPEN, 2024, 5 (09): : 758 - 765
  • [27] Robotic-assisted total knee arthroplasty is associated with the use of thinner polyethylene liners compared to navigation-guided and manual techniques
    Cheng, Ryan
    Kim, Billy
    Taylor, Walter L.
    Westrich, Geoffrey H.
    Shen, Tony S.
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2024, 32 (09) : 2290 - 2296
  • [28] Use of intraoperative technology in total knee arthroplasty is not associated with reductions in postoperative pain
    Andrew G. Kim
    Zachary Bernhard
    Alexander J. Acuña
    Victoria S. Wu
    Atul F. Kamath
    Knee Surgery, Sports Traumatology, Arthroscopy, 2023, 31 : 1370 - 1381
  • [29] Use of intraoperative technology in total knee arthroplasty is not associated with reductions in postoperative pain
    Kim, Andrew G.
    Bernhard, Zachary
    Acuna, Alexander J.
    Wu, Victoria S.
    Kamath, Atul F.
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2023, 31 (04) : 1370 - 1381
  • [30] Letter to the Editor: Not All Robotic-Assisted Total Knee Arthroplasty Are the Same
    Plaskos, Christopher
    Lawrence, Jeffrey M.
    JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2022, 30 (03) : E313 - E314