PROPORTIONAL DETECTORS OF GAMMA-RADIATION BASED ON HIGH PURITY XENON GAS FOR RADIATION MONITORING

被引:0
|
作者
Sokolov, S. A. [1 ]
Kosinov, A. V. [1 ]
Pudov, A. O. [1 ]
Kutny, V. E. [1 ]
Rybka, A. V. [1 ]
Kovtun, K. V. [1 ]
Melnikov, S. I. [1 ]
Timchenko, I. S. [1 ]
Olejnik, S. N. [1 ]
机构
[1] Natl Sci Ctr Kharkov Inst Phys & Technol, Kharkiv, Ukraine
关键词
HIGH-PRESSURE XENON;
D O I
10.46813/2023-147-146
中图分类号
O57 [原子核物理学、高能物理学];
学科分类号
070202 ;
摘要
This article is dedicated to a detailed investigation of properties of a proportional counter based on the Xe+2%CH4 mixture. A setup for filling the detectors with high purity Xe gas and Xe-based gas mixtures was designed and made. An optimized design of the proportional counters was developed and investigated. The design parameters, such as the material and diameter of the anode, the number and material of the gas mixture inlets, composition and pressure of the gas were improved. The operating regimes of the proportional counters, as well as their thermal stability, were investigated.
引用
收藏
页码:146 / 151
页数:6