Impact of radiation dose reduction and iterative image reconstruction on CT-guided spine biopsies

被引:1
|
作者
Paprottka, Karolin J. [1 ]
Kupfer, Karina [1 ]
Schultz, Vivian [1 ]
Beer, Meinrad [3 ]
Zimmer, Claus [1 ,2 ]
Baum, Thomas [1 ]
Kirschke, Jan S. [1 ,2 ]
Sollmann, Nico [1 ,2 ,3 ]
机构
[1] Tech Univ Munich, Sch Med, Dept Diagnost & Intervent Neuroradiol, Klinikum Rechts Isar, Munich, Germany
[2] Tech Univ Munich, TUM Neuroimaging Ctr, Klinikum Rechts Isar, Munich, Germany
[3] Univ Hosp Ulm, Dept Diagnost & Intervent Radiol, Ulm, Germany
关键词
SUSPECTED INFECTION; LESION BIOPSIES; TUBE CURRENT; PATIENT; FEASIBILITY; YIELD; MDCT;
D O I
10.1038/s41598-023-32102-9
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
This study aimed to systematically evaluate the impact of dose reduction on image quality and confidence for intervention planning and guidance regarding computed tomography (CT)-based intervertebral disc and vertebral body biopsies. We retrospectively analyzed 96 patients who underwent multi-detector CT (MDCT) acquired for the purpose of biopsies, which were either derived from scanning with standard dose (SD) or low dose (LD; using tube current reduction). The SD cases were matched to LD cases considering sex, age, level of biopsy, presence of spinal instrumentation, and body diameter. All images for planning (reconstruction: "IMR1") and periprocedural guidance (reconstruction: "iDose4") were evaluated by two readers (R1 and R2) using Likert scales. Image noise was measured using attenuation values of paraspinal muscle tissue. The dose length product (DLP) was statistically significantly lower for LD scans regarding the planning scans (SD: 13.8 +/- 8.2 mGy*cm, LD: 8.1 +/- 4.4 mGy*cm, p < 0.01) and the interventional guidance scans (SD: 43.0 +/- 48.8 mGy*cm, LD: 18.4 +/- 7.3 mGy*cm, p < 0.01). Image quality, contrast, determination of the target structure, and confidence for planning or intervention guidance were rated good to perfect for SD and LD scans, showing no statistically significant differences between SD and LD scans (p > 0.05). Image noise was similar between SD and LD scans performed for planning of the interventional procedures (SD: 14.62 +/- 2.83 HU vs. LD: 15.45 +/- 3.22 HU, p = 0.24). Use of a LD protocol for MDCT-guided biopsies along the spine is a practical alternative, maintaining overall image quality and confidence. Increasing availability of model-based iterative reconstruction in clinical routine may facilitate further radiation dose reductions.
引用
收藏
页数:11
相关论文
共 50 条
  • [11] Percutaneous CT-guided biopsy of the spine: results of 430 biopsies
    Rimondi, Eugenio
    Staals, Eric L.
    Errani, Costantino
    Bianchi, Giuseppe
    Casadei, Roberto
    Alberghini, Marco
    Malaguti, Maria Cristina
    Rossi, Giuseppe
    Durante, Stefano
    Mercuri, Mario
    EUROPEAN SPINE JOURNAL, 2008, 17 (07) : 975 - 981
  • [12] First experiences of a low-dose protocol for CT-guided musculoskeletal biopsies combining different radiation dose reduction techniques
    Alagic, Zlatan
    Alagic, Haris
    Bujila, Robert
    Srivastava, Subhash
    Jasim, Saif
    Lindqvist, Maria
    Wick, Marius C.
    ACTA RADIOLOGICA, 2020, 61 (01) : 28 - 36
  • [13] Percutaneous CT-guided biopsy of the spine: results of 430 biopsies
    Eugenio Rimondi
    Eric L. Staals
    Costantino Errani
    Giuseppe Bianchi
    Roberto Casadei
    Marco Alberghini
    Maria Cristina Malaguti
    Giuseppe Rossi
    Stefano Durante
    Mario Mercuri
    European Spine Journal, 2008, 17 : 975 - 981
  • [14] Radiation Dose and Procedure Time for 994 CT-guided Spine Pain Control Procedures
    Lazarus, Matthew S.
    Forman, Rebecca B.
    Brook, Allan L.
    Miller, Todd S.
    PAIN PHYSICIAN, 2017, 20 (04) : E585 - E591
  • [15] Iterative Reconstruction for Head CT: Effects on Radiation Dose and Image Quality
    Rivers-Bowerman, Michael D.
    Shankar, Jai Jai Shiva
    CANADIAN JOURNAL OF NEUROLOGICAL SCIENCES, 2014, 41 (05) : 620 - 625
  • [16] Radiation Dose Reduction in Temporal Bone CT with Iterative Reconstruction Technique
    Niu, Y. T.
    Mehta, D.
    Zhang, Z. R.
    Zhang, Y. X.
    Liu, Y. F.
    Kang, T. L.
    Xian, J. F.
    Wang, Z. C.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2012, 33 (06) : 1020 - 1026
  • [17] Objective assessment of image quality and dose reduction in CT iterative reconstruction
    Vaishnav, J. Y.
    Jung, W. C.
    Popescu, L. M.
    Zeng, R.
    Myers, K. J.
    MEDICAL PHYSICS, 2014, 41 (07)
  • [18] Effectiveness of CT-guided percutaneous biopsies of the spine: An analysis of 202 examinations
    Heyer, Christoph M.
    Al-Hadari, Abdulgani
    Mueller, Klaus-Michael
    Stachon, Axel
    Nicolas, Volkmar
    ACADEMIC RADIOLOGY, 2008, 15 (07) : 901 - 911
  • [19] CT-guided percutaneous biopsies
    de Bazelaire, C.
    Sabatier, F.
    Pluvinage, A.
    de Kerviler, E.
    JOURNAL DE RADIOLOGIE, 2011, 92 (09): : 842 - 859
  • [20] Image quality guided iterative reconstruction for low-dose CT based on CT image statistics
    Duan, Jiayu
    Mou, Xuanqin
    PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (18):