Laboratory and field evaluation of a low-cost methane sensor and key environmental factors for sensor calibration

被引:5
|
作者
Lin, Joyce J. Y. [1 ]
Buehler, Colby [2 ,3 ]
Datta, Abhirup [4 ]
Gentner, Drew R. [2 ,3 ]
Koehler, Kirsten [1 ,2 ]
Zamora, Misti Levy [1 ,2 ,5 ]
机构
[1] Johns Hopkins Univ, Bloomberg Sch Publ Hlth Environm Hlth & Engn, Baltimore, MD 21205 USA
[2] Yale Univ, SEARCH Solut Energy Air Climate & Hlth Ctr, New Haven, CT 06520 USA
[3] Yale Univ, Chem & Environm Engn, New Haven, CT 06520 USA
[4] Johns Hopkins Univ, Bloomberg Sch Publ Hlth, Dept Biostat, Baltimore, MD 21205 USA
[5] Univ Connecticut Hlth Ctr, UConn Sch Med, Dept Publ Hlth Sci, Farmington, CT 06032 USA
来源
ENVIRONMENTAL SCIENCE-ATMOSPHERES | 2023年 / 3卷 / 04期
基金
美国国家科学基金会; 美国国家卫生研究院;
关键词
EMISSIONS;
D O I
10.1039/d2ea00100d
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Low-cost sensors enable finer-scale spatiotemporal measurements within the existing methane (CH4) monitoring infrastructure and could help cities mitigate CH4 emissions to meet their climate goals. While initial studies of low-cost CH4 sensors have shown potential for effective CH4 measurement at ambient concentrations, sensor deployment remains limited due to questions about interferences and calibration across environments and seasons. This study evaluates sensor performance across seasons with specific attention paid to the sensor's understudied carbon monoxide (CO) interferences and environmental dependencies through long-term ambient co-location in an urban environment. The sensor was first evaluated in a laboratory using chamber calibration and co-location experiments, and then in the field through two 8 week co-locations with a reference CH4 instrument. In the laboratory, the sensor was sensitive to CH4 concentrations below ambient background concentrations. Different sensor units responded similarly to changing CH4, CO, temperature, and humidity conditions but required individual calibrations to account for differences in sensor response factors. When deployed in-field, co-located with a reference instrument near Baltimore, MD, the sensor captured diurnal trends in hourly CH4 concentration after corrections for temperature, absolute humidity, CO concentration, and hour of day. Variable performance was observed across seasons with the sensor performing well (R-2 = 0.65; percent bias 3.12%; RMSE 0.10 ppm) in the winter validation period and less accurately (R-2 = 0.12; percent bias 3.01%; RMSE 0.08 ppm) in the summer validation period where there was less dynamic range in CH4 concentrations. The results highlight the utility of sensor deployment in more variable ambient CH4 conditions and demonstrate the importance of accounting for temperature and humidity dependencies as well as co-located CO concentrations with low-cost CH4 measurements. We show this can be addressed via Multiple Linear Regression (MLR) models accounting for key covariates to enable urban measurements in areas with CH4 enhancement. Together with individualized calibration prior to deployment, the sensor shows promise for use in low-cost sensor networks and represents a valuable supplement to existing monitoring strategies to identify CH4 hotspots.
引用
收藏
页码:683 / 694
页数:12
相关论文
共 50 条
  • [41] Evaluation of nine machine learning regression algorithms for calibration of low-cost PM2.5 sensor
    Kumar, Vikas
    Sahu, Manoranjan
    JOURNAL OF AEROSOL SCIENCE, 2021, 157
  • [42] Evaluation of calibration performance of a low-cost particulate matter sensor using collocated and distant NO2
    Ko, Kabseok
    Cho, Seokheon
    Rao, Ramesh R.
    ATMOSPHERIC MEASUREMENT TECHNIQUES, 2024, 17 (10) : 3303 - 3322
  • [43] Low-Cost Sensor System for Air Purification Process Evaluation
    Moskal, Arkadiusz
    Jagodowicz, Wiktor
    Penconek, Agata
    Zaraska, Krzysztof
    SENSORS, 2024, 24 (06)
  • [44] Improved Performance of A Low-Cost PDR System through Sensor Calibration and Analysis
    Kim, Yunki
    Lee, Donghyuk
    Kim, Kijung
    Lee, Jangmyung
    2014 IEEE/ASME INTERNATIONAL CONFERENCE ON ADVANCED INTELLIGENT MECHATRONICS (AIM), 2014, : 1747 - 1752
  • [45] A new calibration system for low-cost Sensor Network in air pollution monitoring
    Cui, Houxin
    Zhang, Ling
    Li, Wanxin
    Yuan, Ziyang
    Wu, Mengxian
    Wang, Chunying
    Ma, Jingjin
    Li, Yi
    ATMOSPHERIC POLLUTION RESEARCH, 2021, 12 (05)
  • [46] CALIBRATION AND CHARACTERIZATION OF A LOW-COST WIRELESS SENSOR FOR APPLICATIONS IN CNC END MILLING
    Harmon, Andrew
    Fussell, Barry K.
    Jerard, Robert B.
    PROCEEDINGS OF THE ASME INTERNATIONAL MANUFACTURING SCIENCE AND ENGINEERING CONFERENCE, 2012, 2012, : 823 - 832
  • [47] An efficient catadioptric sensor calibration based on a low-cost test-pattern
    Ragot, N.
    Ertaud, J. Y.
    Savatier, X.
    Mazari, B.
    VISAPP 2006: PROCEEDINGS OF THE FIRST INTERNATIONAL CONFERENCE ON COMPUTER VISION THEORY AND APPLICATIONS, VOL 1, 2006, : 11 - +
  • [48] Rethinking Quality Metrics for Low-Cost Urban Environmental Sensor Networks
    Cabral, Alex
    2024 IEEE INTERNATIONAL CONFERENCE ON PERVASIVE COMPUTING AND COMMUNICATIONS WORKSHOPS AND OTHER AFFILIATED EVENTS, PERCOM WORKSHOPS, 2024, : 360 - 361
  • [49] Modular Air Quality Calibration and Forecasting Method for Low-Cost Sensor Nodes
    Hashmy, Yousuf
    Khan, Zill Ullah
    Ilyas, Fahad
    Hafiz, Rehan
    Younis, Usman
    Tauqeer, Tauseef
    IEEE SENSORS JOURNAL, 2023, 23 (04) : 4193 - 4203
  • [50] Smart Multi-Sensor Calibration of Low-Cost Particulate Matter Monitors
    Villanueva, Edwin
    Espezua, Soledad
    Castelar, George
    Diaz, Kyara
    Ingaroca, Erick
    SENSORS, 2023, 23 (07)