摘要
Background. Volume overload is a fatal complication for people undergoing hemodialysis. Therefore, regulating a patient's "dry weight" based on their fluid status is imperative. Clinical experiences are too subjective to accurately judge a patient's fluid status, but techniques have emerged for improved fluid control in the two decades. Specifically, lung ultrasonography (LUS) uses a unique aspect of ultrasound images, the B-lines, to evaluate extravascular lung water, which has increasingly attracted attention. However, the role of B-line quantification in predicting short-mid-term death and/or cardiovascular complications is unclear. Methods. Patients undergoing MHD at the hemodialysis center of Zhejiang Provincial People's Hospital from October 1, 2020, to February 28, 2021, were examined using LUS and a bioelectrical impedance analysis before and after dialysis, and related clinical data were collected. All patients were followed up for one year after the examination, and deaths and first cardiovascular events (e.g., stroke, myocardial infarction, and heart failure) during this period were recorded. Results. 98 patients were enrolled and divided into three groups in relation to their mild (<16 B-lines), moderate (16-30 B-lines), or severe (>30 B-lines) hypervolemia, defined by the number of B-lines. The long-term survival rate was significantly lower in the severe group than in the mild and moderate groups. LUS and bioelectrical impedance-related parameters (e.g., extracellular water-to-water ratio) were closely related to cardiac ultrasound parameters (left ventricular ejection fraction) (P<0.001). The optimal B-line cutoff value on LUS for predicting fluid overload (defined clinically) in patients on hemodialysis was 11.5 lines (AUC = 0.840, 95% confidence interval 0.735-0.945, P<0.001), and the diagnostic sensitivity and specificity were both 76.5%. During the one-year follow-up period, ten deaths and six cardiovascular events occurred. The survival rate was significantly lower in the severe group than in the mild group (log-rank test chi(2) = 10.050, P=0.002) but did not differ between the severe and moderate groups (chi(2) = 2.629, P=0.105). Conclusion. LUS is a cheap, noninvasive, simple, and repeatable volume-monitoring method that can assist with individualized fluid volume management in patients undergoing MHD. LUS results may also help to predict the short-mid-term survival rate of patients to a certain extent.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] EVOLUTION OF NUTRITIONAL-STATUS IN PATIENTS UNDERGOING MAINTENANCE HEMODIALYSIS
    SCHWEDT, E
    ANTORIA, T
    BRACCO, HM
    AMBROSONI, P
    CAORSI, H
    NEFROLOGIA, 1993, 13 : 56 - 65
  • [42] Body fluid overload and bioelectrical impedance analysis in renal patients
    Piccoli, A
    Rossi, B
    Pillon, L
    Bucciante, G
    MINERAL AND ELECTROLYTE METABOLISM, 1996, 22 (1-3) : 76 - 78
  • [43] USE OF BIOELECTRICAL-IMPEDANCE ANALYSIS (BIA) FOR THE EVALUATION OF BODY-FLUID COMPOSITION IN HEMODIALYSIS AND CAPD PATIENTS
    PLUM, J
    LUBBE, M
    GRABENSEE, B
    JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 1994, 5 (03): : 525 - 525
  • [44] USE OF BIOELECTRICAL-IMPEDANCE ANALYSIS (BIA) FOR THE EVALUATION OF BODY-FLUID COMPOSITION IN HEMODIALYSIS AND CAPD PATIENTS
    PLUM, J
    LUBBE, M
    GRABENSEE, B
    KIDNEY INTERNATIONAL, 1995, 47 (03) : 993 - 993
  • [45] Bioelectrical impedance analysis before versus after a hemodialysis session in evaluation of nutritional status
    Jankowska, M
    Debska-Slizien, A
    Rutkowski, B
    JOURNAL OF RENAL NUTRITION, 2006, 16 (02) : 137 - 140
  • [46] Assessing lean tissue by bioelectrical impedance analysis pre hemodialysis underestimates the prevalence of sarcopenia in maintenance hemodialysis patients (Jun, 10.1038/s41430-020-00835-9, 2021)
    Wang, Minmin
    Liu, Lin
    Shen, Xiaogang
    Li, Yiwen
    He, Qiang
    EUROPEAN JOURNAL OF CLINICAL NUTRITION, 2022, 76 (02) : 334 - 334
  • [47] BIOELECTRICAL IMPEDANCE PHASE ANGLE AS AN INDICATOR OF FLUID STATUS IN CRITICALLY ILL PATIENTS
    Takasu, Osamu
    Tashiro, Keita
    Uzu, Hideaki
    Kannae, Mikinori
    Moroki, Mariko
    Hirayu, Tsunehisa
    Morita, Toshio
    Nabeta, Masakazu
    Nakamura, Atsuo
    Yamashita, Norio
    SHOCK, 2016, 46 (04): : 67 - 67
  • [48] Evaluation of anemia, malnutrition, mineral, and bone disorder for maintenance hemodialysis patients based on bioelectrical impedance vector analysis (BIVA)
    Zhijian Zhang
    Daheng Yin
    Hanzhi Chen
    Bin Liu
    Xiaobin Liu
    Weiwei Shan
    Jia Hua
    Zhen Qi
    Yue Zhang
    Qiuhua Zhang
    Yong Chen
    Liang Wang
    Ya Guo
    Zhuxing Sun
    Clinical and Experimental Nephrology, 2020, 24 : 1162 - 1176
  • [49] Bioelectrical Impedance Analysis-Derived Phase Angle Predicts Protein-Energy Wasting in Maintenance Hemodialysis Patients
    Tan, Rong-shao
    Liang, Dan-hua
    Liu, Yan
    Zhong, Xiao-shi
    Zhang, Dong-sheng
    Ma, Jing
    JOURNAL OF RENAL NUTRITION, 2019, 29 (04) : 295 - 301
  • [50] Bioelectrical impedance analysis-derived phase angle predicts possible Sarcopenia in patients on maintenance hemodialysis: a retrospective study
    Zeng, Ying
    Chen, Yang
    Yang, Yujie
    Qiu, Ying
    Fu, Ping
    Yuan, Huaihong
    BMC NEPHROLOGY, 2024, 25 (01)