Reversed-Phase Liquid Chromatography Methods Based on C18 Polymer Monoliths for the Determination of Urinary Myoglobin

被引:0
|
作者
Vitek, Renan [1 ]
do Nascimento, Fernando H. [2 ]
Masini, Jorge C. [2 ]
机构
[1] Inst Fed Educ Ciencia & Tecnol Mato Grosso, BR-78043409 Cuiaba, MT, Brazil
[2] Univ Sao Paulo, Dept Quim Fundamental, Inst Quim, Ave Prof Lineu Pestes,748, BR-05508000 Sao Paulo, SP, Brazil
关键词
protein separation; narrow-bore chromatography; monolithic columns; sample preparation; flow analysis; solid phase extraction; SEQUENTIAL INJECTION CHROMATOGRAPHY; SEPARATION; EXTRACTION; PROTEINS; RHABDOMYOLYSIS; FABRICATION; COLUMNS; ALBUMIN; MUSCLE; ONLINE;
D O I
10.21577/0103-5053.20230084
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
This study describes reversed-phase liquid chromatography (RPLC) methods to quantify urinary myoglobin using polymer monolithic columns produced by copolymerization of stearyl methacrylate (SMA) and ethylene glycol dimethacrylate (EDMA). The columns were prepared in the coffins of 1.5 mm internal diameter (i.d.) ethylene tetrafluoroethylene (ETFE) tubing for use in sequential injection chromatography (SIC) and solid phase extraction (SPE), and inside 1.0 mm i.d. Silcosteel & REG; tube for use in narrow-bore liquid chromatography. The monoliths inside the ETFE were produced via UV, whereas thermal polymerization formed the monoliths inside the Silcosteel & REG; tube. The separation of carbonic anhydrase, lysozyme, and myoglobin was demonstrated because they may occur simultaneously in urine samples. Quantification was undertaken by external calibration, and the accuracy was evaluated by the spiking/recovery strategy. The methods exhibited linearity from 5.0 to 60 & mu;g mL-1 (SIC), 2.5 to 50 & mu;g mL-1 (high-performance liquid chromatography (HPLC)), and 1.0 to 7.5 & mu;g mL-1 for an SPE-HPLC method. The lowest limits of detection and quantifications were 0.13 and 0.43 jig L-1, respectively, obtained after concentrating myoglobin by SPE. Recoveries ranged from 98 to 105%. The low cost, simplicity, reusability, and analytical features provided by these polymeric stationary phases make them affordable alternatives to routine analyses of urinary myoglobin.
引用
收藏
页码:1601 / 1610
页数:10
相关论文
共 50 条
  • [31] Determination of the Lipophilicity of Xanthines by Reversed-Phase Liquid Chromatography
    Ta’ána Gondová
    Milena Vincová
    Karol Flórián
    JPC – Journal of Planar Chromatography – Modern TLC, 2004, 17 : 156 - 158
  • [32] Determination of phenyltin compounds by reversed-phase liquid chromatography
    Kalambaheti, C
    Wilairat, P
    Sakulpaisith, N
    Visoottiviseth, P
    APPLIED ORGANOMETALLIC CHEMISTRY, 1998, 12 (01) : 1 - 12
  • [33] Determination of polyolefin additives by reversed-phase liquid chromatography
    Dopico-Garcia, M. Sonia
    Noguerol-Cal, Rosalia
    Castro-Lopez, M. Mar
    Cela-Perez, M. Concepcion
    Pinon-Giz, Elena
    Lopez-Vilarino, Jose M.
    Gonzalez-Rodriguez, M. Victoria
    CENTRAL EUROPEAN JOURNAL OF CHEMISTRY, 2012, 10 (03): : 585 - 610
  • [34] DETERMINATION OF URINARY OXALATE BY REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    JEREZ, E
    DELAPIEDRA, C
    TRABA, ML
    REVISTA ESPANOLA DE FISIOLOGIA, 1986, 42 (01): : 37 - 43
  • [35] TECHNOLOGIES FOR AN IMPROVED C18 STATIONARY PHASE IN REVERSED-PHASE HPLC SEPARATIONS
    KIRKLAND, JJ
    DILKS, CH
    HENDERSON, JE
    LC GC-MAGAZINE OF SEPARATION SCIENCE, 1993, 11 (04): : 290 - &
  • [36] CHARACTERIZATION OF POLYMER-COATED C-18 PACKING MATERIALS FOR REVERSED-PHASE LIQUID-CHROMATOGRAPHY
    SHIROTA, O
    OHTSU, Y
    NAKATA, O
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1990, 28 (11) : 553 - 558
  • [37] DETERMINATION OF INORGANIC ANIONS IN SALT-SOLUTIONS BY ION CHROMATOGRAPHY USING C18 REVERSED-PHASE COLUMNS COATED WITH CETYLTRIMETHYLAMMONIUM
    ITO, K
    ARIYOSHI, Y
    SUNAHARA, H
    JOURNAL OF CHROMATOGRAPHY, 1992, 598 (02): : 237 - 241
  • [38] Using pH to alter reversed-phase selectivity with Gemini™ C18
    Loo, L
    McGinley, M
    LC GC EUROPE, 2005, : 45 - 45
  • [39] REVERSED-PHASE THIN-LAYER CHROMATOGRAPHY OF CHLOROPLAST PIGMENTS ON CHEMICALLY BONDED C18 PLATES
    SHERMA, J
    LATTA, M
    JOURNAL OF CHROMATOGRAPHY, 1978, 154 (01): : 73 - 75
  • [40] POLYMER-BASED PACKING MATERIALS FOR REVERSED-PHASE LIQUID-CHROMATOGRAPHY
    TANAKA, N
    ARAKI, M
    ADVANCES IN CHROMATOGRAPHY, 1989, 30 : 81 - 122