Reversed-Phase Liquid Chromatography Methods Based on C18 Polymer Monoliths for the Determination of Urinary Myoglobin

被引:0
|
作者
Vitek, Renan [1 ]
do Nascimento, Fernando H. [2 ]
Masini, Jorge C. [2 ]
机构
[1] Inst Fed Educ Ciencia & Tecnol Mato Grosso, BR-78043409 Cuiaba, MT, Brazil
[2] Univ Sao Paulo, Dept Quim Fundamental, Inst Quim, Ave Prof Lineu Pestes,748, BR-05508000 Sao Paulo, SP, Brazil
关键词
protein separation; narrow-bore chromatography; monolithic columns; sample preparation; flow analysis; solid phase extraction; SEQUENTIAL INJECTION CHROMATOGRAPHY; SEPARATION; EXTRACTION; PROTEINS; RHABDOMYOLYSIS; FABRICATION; COLUMNS; ALBUMIN; MUSCLE; ONLINE;
D O I
10.21577/0103-5053.20230084
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
This study describes reversed-phase liquid chromatography (RPLC) methods to quantify urinary myoglobin using polymer monolithic columns produced by copolymerization of stearyl methacrylate (SMA) and ethylene glycol dimethacrylate (EDMA). The columns were prepared in the coffins of 1.5 mm internal diameter (i.d.) ethylene tetrafluoroethylene (ETFE) tubing for use in sequential injection chromatography (SIC) and solid phase extraction (SPE), and inside 1.0 mm i.d. Silcosteel & REG; tube for use in narrow-bore liquid chromatography. The monoliths inside the ETFE were produced via UV, whereas thermal polymerization formed the monoliths inside the Silcosteel & REG; tube. The separation of carbonic anhydrase, lysozyme, and myoglobin was demonstrated because they may occur simultaneously in urine samples. Quantification was undertaken by external calibration, and the accuracy was evaluated by the spiking/recovery strategy. The methods exhibited linearity from 5.0 to 60 & mu;g mL-1 (SIC), 2.5 to 50 & mu;g mL-1 (high-performance liquid chromatography (HPLC)), and 1.0 to 7.5 & mu;g mL-1 for an SPE-HPLC method. The lowest limits of detection and quantifications were 0.13 and 0.43 jig L-1, respectively, obtained after concentrating myoglobin by SPE. Recoveries ranged from 98 to 105%. The low cost, simplicity, reusability, and analytical features provided by these polymeric stationary phases make them affordable alternatives to routine analyses of urinary myoglobin.
引用
收藏
页码:1601 / 1610
页数:10
相关论文
共 50 条
  • [1] A simplified method for the determination of taxanes in yew needles by reversed-phase (C18) high pressure liquid chromatography
    Department of Organic Chemistry, Phytochemical Section, Agricultural University, Dreijenplein 8, NL-6703 HB Wageningen, Netherlands
    PHYTOCHEM. ANAL., 6 (286-293):
  • [2] Behaviour of proteins on reversed-phase supports during high performance liquid chromatography on C18 stationary phase
    Rotkaja, Oksana
    Golushko, Jelena
    Mekss, Peteris
    PROCEEDINGS OF THE ESTONIAN ACADEMY OF SCIENCES, 2015, 64 (01) : 36 - 42
  • [3] A C18-DERIVATIZED POLYMER FOR REVERSED-PHASE CHROMATOGRAPHY
    MACBLANE, D
    KITAGAWA, N
    BENSON, JR
    AMERICAN LABORATORY, 1987, 19 (02) : 134 - &
  • [4] Click oligo(ethylene glycol): An excellent orthogonal stationary phase to C18 for two-dimensional reversed-phase/reversed-phase liquid chromatography
    Liu, Yanming
    Guo, Zhimou
    Jin, Yu
    Xue, Xingya
    Xu, Qing
    Zhang, Feifang
    Liang, Xinmiao
    JOURNAL OF CHROMATOGRAPHY A, 2008, 1206 (02) : 153 - 159
  • [5] A new imidazolium-embedded C18 stationary phase with enhanced performance in reversed-phase liquid chromatography
    Qiu, Hongdeng
    Mallik, Abul K.
    Takafuji, Makoto
    Liu, Xia
    Jiang, Shengxiang
    Ihara, Hirotaka
    ANALYTICA CHIMICA ACTA, 2012, 738 : 95 - 101
  • [6] REVERSED-PHASE C18 HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY OF ACIDIC AND CONJUGATED GIBBERELLINS
    KOSHIOKA, M
    HARADA, J
    TAKENO, K
    NOMA, M
    SASSA, T
    OGIYAMA, K
    TAYLOR, JS
    ROOD, SB
    LEGGE, RL
    PHARIS, RP
    JOURNAL OF CHROMATOGRAPHY, 1983, 256 (01): : 101 - 115
  • [7] PEPTIDE ANALYSIS USING C18 REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    KEMPI, NM
    NAGEL, GM
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1990, 199 : 31 - CHED
  • [8] PROPYLAMIDO-MODIFIED C18 REVERSED-PHASE FOR HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    LIN, JY
    YANG, MH
    JOURNAL OF THE CHINESE CHEMICAL SOCIETY, 1991, 38 (06) : 543 - 548
  • [9] C18 Reversed-Phase Liquid Chromatography Column Coupled with Ion Chromatography: a Method for the Determination of Trimethylamine Hydrochloride Residues in Cationic Etherifying Agent
    Han, Ke
    Zhong, Zhenhua
    Zhang, Liang
    Hu, Qiongzheng
    Ji, Wenhua
    Liu, Shuhua
    CHROMATOGRAPHIA, 2022, 85 (01) : 83 - 89
  • [10] C18 Reversed-Phase Liquid Chromatography Column Coupled with Ion Chromatography: a Method for the Determination of Trimethylamine Hydrochloride Residues in Cationic Etherifying Agent
    Ke Han
    Zhenhua Zhong
    Liang Zhang
    Qiongzheng Hu
    Wenhua Ji
    Shuhua Liu
    Chromatographia, 2022, 85 : 83 - 89