Comparison of Resistance to Fracture of Endodontically Treated Teeth Reinforced with Various Posts: An In-vitro Study

被引:0
|
作者
Ramachandran, Sajani [1 ]
Babu, Suresh [1 ,4 ]
Manikandan [2 ]
Ranukumari [3 ]
机构
[1] Pondicherry Inst Med Sci, Dept Dent, Pondicherry, India
[2] Pondicherry Inst Med Sci, Dept Community Med, Pondicherry, India
[3] Mahatma Gandhi Post Grad Inst Dent Sci, Dept Prosthodont, Pondicherry, India
[4] 49 AFT Mill Rd, Pondicherry 605004, India
关键词
Compressive strength; Core; Fibre post; Titanium post;
D O I
10.7860/JCDR/2023/59459.17694
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Endodontically treated tooth reinforced with posts should restore its lost structural integrity, as well as withstand the various masticatory forces. Choosing the appropriate post, so that a durable prosthesis can be given, is often a challenge to a restorative dentist.Aim: To compare the resistance to fracture, of endodontically treated teeth restored with the various posts when subjected to compressive loads, and analyse the different types of fractures and cracks which are visible under normal eye, microscope and radiograph.Materials and Methods: An in-vitro study was conducted in the Department of Dentistry, Pondicherry Institute of Medical Sciences, Puducherry, India, from February 2019 to March 2020. Study was done with four types of posts namely cast post, stainless steel, fibre and titanium on seventy extracted teeth, which were randomly allocated into five groups with one group as control without any post. The teeth were subjected to increasing compressive loads with universal testing machine and the loads at which fracture occurred was recorded. The data was analysed statistically with one way Analysis of Variance (ANOVA) and the groups were compared with Tukey's HSD test. The types of fractures that occurred were also analysed. Results: The loads at which the teeth reinforced with various posts fractured, showed significant difference (p-value <0.0001). The mean load at which fracture occurred for teeth restored without any posts was 711.6086 N and teeth with stainless steel post was highest at 1605.955 N. Those with titanium posts were found to have minimum microcracks (14.2%) when seen under dissection microscope. Maximum number of teeth with titanium posts had favourable fracture and withstood the load (64.29%), with fracture occurring only at root tip and no fracture elsewhere. Tukey's HSD test was done to compare the fracture resistance between the groups at 0.05 level of significance. There was no significant difference in the load at which fracture occurred between groups.Conclusion: In the present study, of all different post and core materials, stainless steel post resisted highest load and titanium posts had favourable fractures.
引用
收藏
页码:ZC47 / ZC52
页数:6
相关论文
共 50 条
  • [21] FRACTURE RESISTANCE OF ENDODONTICALLY TREATED TEETH RESTORED WITH GLASS FIBER POSTS OF DIFFERENT LENGTHS
    Franco, Erico Braga
    do Valle, Accacio Lins
    Pompeia Fraga de Almeida, Ana Lucia
    Rubo, Jose Henrique
    Pereira, Jefferson Ricardo
    JOURNAL OF PROSTHETIC DENTISTRY, 2014, 111 (01): : 30 - 34
  • [22] Analysis of Fracture Resistance of Endodontically Treated Teeth with Different Restorative Materials: An In vitro Study
    Manas, Abhigyan
    Kumar, Amit
    Gawali, Kranti Sorte
    Ismail, Prabu Mahin Syed
    Goutam, Manish
    Das, Indrani
    JOURNAL OF PHARMACY AND BIOALLIED SCIENCES, 2022, 14 : 977 - 979
  • [23] Effect of Newer Intraorifice Barriers on the Fracture Resistance of Endodontically Treated Teeth: An In Vitro Study
    D'souza, Johanna M.
    de Ataide, Ida de Noronha
    Lambor, Rajan
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (09)
  • [24] Effect of novel restoration techniques on the fracture resistance of teeth treated endodontically: An in vitro study
    Kemaloglu, Hande
    Emin Kaval, Mehmet
    Turkun, Murat
    Micoogullari Kurt, Seniha
    DENTAL MATERIALS JOURNAL, 2015, 34 (05) : 618 - 622
  • [25] In-vitro comparison of fracture resistance of CAD/CAM porcelain restorations for endodontically treated molars
    Uzun, Ismail
    Timur, Ata Hikmet
    Senel, Kevser
    BMC ORAL HEALTH, 2024, 24 (01):
  • [26] RESISTANCE TO CUSP FRACTURE IN ENDODONTICALLY TREATED TEETH
    WENDT, SL
    HARRIS, BM
    HUNT, TE
    DENTAL MATERIALS, 1987, 3 (05) : 232 - 235
  • [27] Effect of fibre-reinforced composite on the fracture resistance of endodontically treated teeth
    Ozsevik, Abdul Semih
    Yildirim, Cihan
    Aydin, Ugur
    Culha, Emre
    Surmelioglu, Derya
    AUSTRALIAN ENDODONTIC JOURNAL, 2016, 42 (02) : 82 - 87
  • [28] RESISTANCE TO FRACTURE OF RESTORED, ENDODONTICALLY TREATED TEETH
    TROPE, M
    MALTZ, DO
    TRONSTAD, L
    JOURNAL OF DENTAL RESEARCH, 1984, 63 : 229 - 229
  • [29] Effect of partial ferrule on fracture resistance of endodontically treated teeth: A meta-analysis of in-vitro studies
    Al-Sanabani, Fuad Ateik
    AL-Makramani, Bandar Mohammed
    Alaajam, Wafa Hassan
    Al-Ak'hali, Mohammed Sultan
    Alhajj, Mohammed Nasser
    Nassani, Mohammad Zakaria
    Assad, Mounzer
    Al-Maweri, Sadeq Ali
    JOURNAL OF PROSTHODONTIC RESEARCH, 2023, 67 (03) : 348 - 359
  • [30] The Influence on Fracture Resistance of Different Composite Resins and Prefabricated Posts to Restore Endodontically Treated Teeth
    Pamato, Saulo
    Ricci, Weber Adad
    Kuga, Milton Carlos
    Gulin de Oliveira, Eliane Cristina
    Silos Moraes, Joao Carlos
    Reis So, Marcus Vinicius
    Trevisan, Tamara Carolina
    Fahl Junior, Newton
    Pereira, Jefferson Ricardo
    POLYMERS, 2023, 15 (01)