The diagnostic performance of endobronchial ultrasound with Xpert MTB/RIF Ultra in smear-negative pulmonary tuberculosis

被引:8
|
作者
Yao, Lan [1 ]
Chen, Shanhao [1 ]
Sha, Wei [1 ]
Gu, Ye [2 ]
机构
[1] Tongji Univ Sch Med, Shanghai Pulm Hosp, Clin & Res Ctr TB, Shanghai Key Lab TB, Shanghai 200433, Peoples R China
[2] Tongji Univ Sch Med, Shanghai Pulm Hosp, Dept Bronchoscopy, Shanghai 200433, Peoples R China
关键词
Pulmonary tuberculosis; Smear-negative; Bronchoscopy; Xpert MTB; RIF Ultra; TRANSBRONCHIAL NEEDLE ASPIRATION; EBUS-TBNA; PLEURAL BIOPSY; YIELD;
D O I
10.1186/s12879-023-08073-7
中图分类号
R51 [传染病];
学科分类号
100401 ;
摘要
ObjectiveThis study investigated the diagnostic performance of endobronchial ultrasound with Xpert MTB/RIF Ultra (Ultra) for detecting smear-negative pulmonary tuberculosis (TB).Methods143 patients suspected of sputum smear-negative pulmonary tuberculosis were enrolled in this study in Shanghai Pulmonary Hospital, China. These patients underwent endobronchial ultrasound with a guide sheath (EBUS-GS) or endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) based on their chest CT manifestations. We assessed the sensitivity and specificity of tissue specimens with Ultra in the TB group and non-TB group. Culture and clinical diagnosis were used as gold-standard for TB.ResultsAmong these 143 patients, 11 patients were culture-positive TB, 85 patients were diagnosed with culture-negative TB and 47 were with the non-TB diseases. Direct testing with microscopy (Acid-Fast Bacilli smear, AFB), liquid culture, pathology, Xpert MTB/RIF(Xpert) test and Ultra had a sensitivity of 8.3%, 11.5%, 42.7%, 64.6%, and 78.1% individually among all the TB patients. Ultra had a higher sensitivity than Xpert (P = 0.011). But Ultra had a specificity of 59.6% (95% CI 44.3-73.3), lower than that of Xpert (89.4%, 95% CI 76.1-96.0, P = 0.001). Ultra had the same sensitivity on specimens from EBUS-TBNA and EBUS-GS (P = 0.975). Ultra's positive predictive value and negative predictive value were 79.8% and 57.1% respectively.ConclusionsTissue specimens from interventional bronchoscopy combined with Ultra provide a sensitive method for diagnosing smear-negative pulmonary tuberculosis, but its specificity was lower than Xpert.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] DIAGNOSTIC TEST OF SPUTUM GENEXPERT MTB/RIF FOR SMEAR NEGATIVE PULMONARY TUBERCULOSIS
    Reechaipichitkul, Wipa
    Phetsuriyawong, Attawoot
    Chaimanee, Prajuab
    Ananta, Pimjai
    SOUTHEAST ASIAN JOURNAL OF TROPICAL MEDICINE AND PUBLIC HEALTH, 2016, 47 (03) : 457 - 466
  • [32] The transition to Xpert MTB/RIF ultra: diagnostic accuracy for pulmonary tuberculosis in Kampala, Uganda
    A. Andama
    D. Jaganath
    R. Crowder
    L. Asege
    M. Nakaye
    D. Katumba
    J. Mukwatamundu
    S. Mwebe
    C. F. Semitala
    W. Worodria
    M. Joloba
    S. Mohanty
    A. Somoskovi
    A. Cattamanchi
    BMC Infectious Diseases, 21
  • [33] Diagnostic value of Xpert MTB/RIF Ultra for osteoarticular tuberculosis
    Sun, Qing
    Wang, Shuqi
    Dong, Weijie
    Jiang, Guanglu
    Huo, Fengmin
    Ma, Yifeng
    Huang, Hairong
    Wang, Guirong
    JOURNAL OF INFECTION, 2019, 79 (02) : 153 - 158
  • [34] DIAGNOSTIC TEST OF SPUTUM GENEXPERT MTB/RIF FOR SMEAR NEGATIVE PULMONARY TUBERCULOSIS
    Phetsuriyawong, A.
    Reechaipichitkul, W.
    RESPIROLOGY, 2016, 21 : 94 - 94
  • [35] PREDICTIVE ACCURACY AND CLINICAL IMPACT OF XPERT MTB/RIF FOR THE DIAGNOSIS OF SPUTUM SMEAR-NEGATIVE PULMONARY TUBERCULOSIS USING BRONCHOALVEOLAR LAVAGE FLUID
    Ho, W.
    Connell, D. W.
    Singanayagam, A.
    Singanayagam, A.
    Donaldson, H.
    Kon, O. M.
    THORAX, 2015, 70 : A26 - A26
  • [36] Comparison of the diagnostic efficacy of the CapitalBio Mycobacterium real-time polymerase chain reaction detection test and Xpert MTB/RIF in smear-negative pulmonary tuberculosis
    Hong Zheng
    Fangming Zhong
    Guocan Yu
    Yanqin Shen
    European Journal of Clinical Microbiology & Infectious Diseases, 2021, 40 : 969 - 977
  • [37] The value of GeneXpert MTB/RIF in bronchoalveolar lavage fluid in the diagnosis of smear-negative pulmonary tuberculosis
    Zhou, Yue-Ying
    Shi, Ji-Chan
    Pan, Ning
    Wu, Zheng-Xing
    Cheng, Ai-Qiong
    Mei, Yan-Hong
    Wu, Lian-Peng
    Jiang, Xian-Gao
    INVESTIGACION CLINICA, 2021, 62 (01): : 28 - 36
  • [38] The transition to Xpert MTB/RIF ultra: diagnostic accuracy for pulmonary tuberculosis in Kampala, Uganda
    Andama, A.
    Jaganath, D.
    Crowder, R.
    Asege, L.
    Nakaye, M.
    Katumba, D.
    Mukwatamundu, J.
    Mwebe, S.
    Semitala, C. F.
    Worodria, W.
    Joloba, M.
    Mohanty, S.
    Somoskovi, A.
    Cattamanchi, A.
    BMC INFECTIOUS DISEASES, 2021, 21 (01)
  • [39] Comparison of the diagnostic efficacy of the CapitalBio Mycobacterium real-time polymerase chain reaction detection test and Xpert MTB/RIF in smear-negative pulmonary tuberculosis
    Zheng, Hong
    Zhong, Fangming
    Yu, Guocan
    Shen, Yanqin
    EUROPEAN JOURNAL OF CLINICAL MICROBIOLOGY & INFECTIOUS DISEASES, 2021, 40 (05) : 969 - 977
  • [40] Impact of Larger Sputum Volume on Xpert® MTB/RIF Assay Detection of Mycobacterium tuberculosis in Smear-Negative Individuals with Suspected Tuberculosis
    Badal-Faesen, Sharlaa
    Firnhaber, Cynthia
    Kendall, Michelle A.
    Wu, Xingye
    Grinsztejn, Beatriz
    da Silva Escada, Rodrigo Otavio
    Fernandez, Michel
    Hogg, Evelyn
    Sanne, Ian
    Johnson, Pamela
    Alland, David
    Mazurek, Gerald H.
    Benator, Debra A.
    Luetkemeyer, Anne F.
    JOURNAL OF CLINICAL MEDICINE, 2017, 6 (08):